NextSDS Logo
Safety Data Sheet EN

COPPER 1000 PPM A/S STANDARD

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
COPPER 1000 PPM A/S STANDARD
Product Code
N9300114

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Laboratory chemicals

Manufacturers & Suppliers

P

PerkinElmer, Inc.

manufacturer

710 Bridgeport Avenue, Shelton, Connecticut 06484 USA

203-925-4600

Emergency Contacts

CHEMTREC

800-424-9300

CHEMTREC

+1 703-527-3887

CHEMTREC

+(61)-290372994

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H319 Causes serious eye irritation.

Precautionary Statements

P264 Wash thoroughly after handling.
P280 Wear protective gloves / eye protection / face protection.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P332 + P313 If skin irritation occurs: Get medical advice/attention.
P337 + P313 If eye irritation persists: Get medical advice/attention.
P362 + P364 Take off contaminated clothing and wash it before reuse.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
Nitric Acid EC: 231-714-2 7697-37-2 2% Yes
Water EC: 231-791-2 7732-18-5 97.9% No
copper EC: 231-159-6 7440-50-8 0.1% No

For the wording of the listed hazard phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

In case of unconsciousness place patient stably in side position for transportation.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

If symptoms persist consult doctor.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use fire extinguishing methods suitable to surrounding conditions.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required

Environmental

Inform respective authorities in case of seepage into water course or sewage system. Dilute with plenty of water. Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material

Materials: sand, diatomite, acid binders, universal binders, sawdust

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special precautions are necessary if used correctly.

Storage

Keep container tightly sealed.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Hands

Protective gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Tightly sealed goggles

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Transparent
Colour
Transparent
Colour Intensity
---
Form
Liquid
Odor
Odourless
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
0 °C
Boiling Point
100 °C
Flash Point
Not applicable.
Freezing Point
0 °C
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
23 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
1 g/cm³
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined.
Solubility
---
Partition Coefficient
Not determined.
Solubility In Water
Fully miscible.
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No decomposition if used according to specifications.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Aquatic toxicity: No further relevant information available.

No further relevant information available regarding aquatic toxicity.

12.2 Persistence and degradability

Not provided

12.3 Bioaccumulative potential

Not provided

12.4 Mobility in soil

Not provided

12.5 Results of PBT and vPvB assessment

Not provided

12.6 Endocrine disrupting properties

Not provided

12.7 Other adverse effects

Not provided

12.2 Persistence and degradability

No further relevant information available.

12.3 Bioaccumulative potential

No further relevant information available.

No further relevant information available.

12.4 Mobility in soil

No further relevant information available.

No further relevant information available.

12.5 Results of PBT and vPvB assessment

PBT: Not applicable. vPvB: Not applicable.

The substance is not considered to be PBT or vPvB.

12.6 Other adverse effects

No further relevant information available.

No further relevant information available.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Disposal

Must not be disposed together with household garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
UN3264
Shipping Name
CORROSIVE LIQUID, ACIDIC, INORGANIC, N.O.S. (Nitric Acid)
Transport Class
8
Packing Group
III
ADR

Warning: Corrosive substances.

IMDG

Warning: Corrosive substances.

IATA

Warning: Corrosive substances.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for COPPER 1000 PPM A/S STANDARD?

The signal word is warning.

What is the physical form of COPPER 1000 PPM A/S STANDARD?

COPPER 1000 PPM A/S STANDARD is a liquid appearing as transparent with transparent color. It has odourless odor.

What is COPPER 1000 PPM A/S STANDARD used for?

Laboratory chemicals

What are the hazard statements for COPPER 1000 PPM A/S STANDARD?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H319: Causes serious eye irritation.

What is the melting point of COPPER 1000 PPM A/S STANDARD?

The melting point is 0 °C and the boiling point is 100 °C.