Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Attune™ NxT Flow Cell Cleaning Solution
- Product Code
- A43635
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
For research use only. Not for use in diagnostic procedures
Manufacturers & Suppliers
Life Technologies Corporation
manufacturer
5781 Van Allen Way, PO Box 6482, Carlsbad, CA 92008
+1 760 603 7200
Life Technologies
distributor
5250 Mainway Drive, Burlington, ONT, CANADA L7L 6A4
800/263-6236
Emergency Contacts
CHEMTREC
1-800-424-9300
CHEMTREC
1-703-527-3887
CHEMTREC
1-703-741-5970
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. If not breathing, give artificial respiration. Remove person to fresh air and keep comfortable for breathing.
Symptoms: H335 - May cause respiratory irritation
Wash off immediately with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Take off immediately all contaminated clothing. Rinse skin with water/ shower.
Symptoms: H314 - Causes severe skin burns and eye damage
Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Symptoms: H314 - Causes severe skin burns and eye damage
Call a POISON CENTER or doctor/physician if you feel unwell.
Immediate Medical Attention
Immediate medical attention is required. Immediate medical attention is required. Call a physician or poison control center immediately. Call a physician or poison control center immediately.
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water spray. Carbon dioxide (CO₂). Foam. Dry chemical.
No information available.
No data
Standard procedure for chemical fires.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No special environmental precautions required.
Soak up with inert absorbent material.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Always wear recommended Personal Protective Equipment. Avoid contact with eyes, skin and clothing. When using do not smoke, eat or drink. Avoid breathing vapors or mists. See section 8 for more information.
Keep in a dry, cool and well-ventilated place. Keep container tightly closed. ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Keep in properly labeled containers. Store in accordance with local regulations.
Handle in accordance with good industrial hygiene and safety practice. Keep away from food, drink and animal feeding stuffs. Do not eat, drink or smoke when using this product. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash hands before breaks and immediately after handling the product.
ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area).
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable under normal conditions.
Hazardous reaction has not been reported.
No information available.
No dangerous reaction known under conditions of normal use.
None under normal use conditions.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Toxicity
The environmental impact of this product has not been fully investigated.
12.1 Toxicity
No data available for algae, daphnia, fish, or microtox.
12.3 Bioaccumulative potential
Persistence and degradability
Bioaccumulative potential
Mobility in soil
Results of PBT and vPvB assessment
Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The generation of waste should be avoided or minimized wherever possible.
Disposal of this product, its solutions or of any by-products, shall comply with the requirements of all applicable local, regional or national/federal regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 3266
- Shipping Name
- Corrosive liquid, basic, inorganic, n.o.s. (tripotassium phosphate)
- Transport Class
- 8
- Packing Group
- II
Regulatory Information
Chemical regulations, safety assessments, and compliance status
WHMIS Hazard Class: E - Corrosive material, D2B - Toxic materials. This product has been classified in accordance with the hazard criteria of the Controlled Products Regulations (CPR) and the SDS contains all the information required by the CPR.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Attune™ NxT Flow Cell Cleaning Solution?
The signal word is danger.
What is the physical form of Attune™ NxT Flow Cell Cleaning Solution?
Attune™ NxT Flow Cell Cleaning Solution is a liquid .
What is Attune™ NxT Flow Cell Cleaning Solution used for?
For research use only. Not for use in diagnostic procedures
What are the hazard statements for Attune™ NxT Flow Cell Cleaning Solution?
This substance has 3 hazard statements:
- H290: May be corrosive to metals
- H314: Causes severe skin burns and eye damage