Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Attune® 1X Focusing Fluid
Product Code
A24904

Regulatory Identifiers

CAS Number
N/A

Identified Uses

For research use only. Not for use in diagnostic procedures

Manufacturers & Suppliers

L

Life Technologies Corporation

manufacturer

5781 Van Allen Way, PO Box 6482, Carlsbad, CA 92008

+1 760 603 7200

L

Life Technologies

manufacturer

5250 Mainway Drive, Burlington, ONT, CANADA L7L 6A4

800/263-6236

Emergency Contacts

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

CHEMTREC

1-703-741-5970

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Sens. Cat. 1
Aquatic Acute Cat. 3
Aquatic Chronic Cat. 3

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H317 May cause an allergic skin reaction
H412 Harmful to aquatic life with long lasting effects

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapors/spray
P272 Contaminated work clothing should not be allowed out of the workplace
P273 Avoid release to the environment
P280 Wear protective gloves/protective clothing/eye protection/face protection
P302 + P352 IF ON SKIN: Wash with plenty of soap and water
P333 + P313 If skin irritation or rash occurs: Get medical advice/attention
P362 + P364 Take off contaminated clothing and wash it before reuse
P501 Dispose of contents/ container to an approved waste disposal plant

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Mixture, 3(2H)-isothiazolone, 5-chloro-2-methyl-with 2-methyl-3(2H)-isothiazolone 55965-84-9 0.0015 - 0.01% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If symptoms persist, call a physician.

Skin contact

Wash off immediately with plenty of water for at least 15 minutes. Remove and wash contaminated clothing and gloves, including the inside, before re-use. Take off immediately all contaminated clothing. Rinse skin with water/ shower. If skin irritation or rash occurs: Get medical advice/attention.

Symptoms: H317 - May cause an allergic skin reaction

Eye contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes.

Ingestion

Get medical attention if symptoms occur.

Immediate Medical Attention

Immediate medical attention is required. Immediate medical attention is required.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray. Carbon dioxide (CO₂). Foam. Dry chemical.

Unsuitable media

No information available.

Specific hazards

No data

Instructions

Standard procedure for chemical fires.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Environmental

Avoid release to the environment.

Cleanup methods

Soak up with inert absorbent material.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Use personal protective equipment as required. No special handling advices are necessary.

Storage

Keep in a dry, cool and well-ventilated place. Keep in properly labeled containers.

Hygiene

Handle in accordance with good industrial hygiene and safety practice.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas.

Hands

Wear suitable gloves. Glove material: Compatible chemical-resistant gloves.

Eyes

Tight sealing safety goggles.

Respiratory

In case of insufficient ventilation wear respirators and components tested and approved under appropriate government standards.

Skin/Body

Wear suitable protective clothing.

Environmental

Avoid release to the environment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Solution
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
No information available
Colour Intensity
---
Form
---
Odor
No data
Odor Threshold
---
Ph
6-8
Melting Point
---
Boiling Point
---
Flash Point
---
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
---
Flammability
No data
Upper Explosive Limit
---
Lower Explosive Limit
---
Explosive Limits
---
Auto Ignition Temperature
---
Decomposition Temperature
---
Solubility
No data
Partition Coefficient
No data
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
No data
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions.

Reactivity

None known.

Hazardous reactions

Hazardous reaction has not been reported.

Avoid

None known.

Incompatible

No dangerous reaction known under conditions of normal use.

Decomposition

No known hazardous decomposition products.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

Toxicity

Hazardous to the Aquatic Environment. | Chemical Name | Toxicity to algae | Toxicity to daphnia and other aquatic invertebrates | Toxicity to fish | Microtox Data | log Pow | | --- | --- | --- | --- | --- | --- | | Mixture, 3(2H)-isothiazolone, 5-chloro-2-methyl- with 2-methyl-3(2H)-isothiazolone | No data available | No data available | No data available | No data available | logPow>=-0.32 - <=0.7 |

Persistence and degradability

No information available.

Bioaccumulative potential

No information available.

Mobility in soil

No information available.

Results of PBT and vPvB assessment

No information available.

Endocrine disrupting properties

Other adverse effects

No information available.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

The generation of waste should be avoided or minimized wherever possible. This material and its container must be disposed of in according to approved disposal technique.

Disposal

Disposal of this product, its solutions or of any by-products, shall comply with the requirements of all applicable local, regional or national/federal regulations.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Attune® 1X Focusing Fluid?

The signal word is warning.

What is the physical form of Attune® 1X Focusing Fluid?

Attune® 1X Focusing Fluid is a solution with no information available color. It has no data odor.

What is the solubility of Attune® 1X Focusing Fluid?

No data

What is Attune® 1X Focusing Fluid used for?

For research use only. Not for use in diagnostic procedures

What are the hazard statements for Attune® 1X Focusing Fluid?

This substance has 2 hazard statements:

  • H317: May cause an allergic skin reaction
  • H412: Harmful to aquatic life with long lasting effects