Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Havoline XLI (CL00)
- Product Code
- 1032765
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- WG78-YYU1-820G-RY4G
Identified Uses
Corrosion inhibitor for cooling systems.
Uses advised against
None known.
Manufacturers & Suppliers
ARTECO NV
manufacturer
Metropoolstraat 25, B-2900 Schoten (Antwerpen), Belgium
+32 (0) 9 397 06 00
Emergency Contacts
Emergency Contact
+44 20 35147487
24hr
Emergency Contact
112
Available 24 hours a day.
National Poisons Control Centre
070 245 245
Available 24 hours a day.
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS08
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Sodium 2-ethylhexanoate EC: 243-283-8 | 19766-89-3 | 10 - 30% | Yes |
| Methyl-1H-benzotriazole EC: 249-596-6 | 29385-43-1 | 0.1 - 2.5% | Yes |
| Imidazole EC: 206-019-2 | 288-32-4 | 0.1 - 0.3% | Yes |
Notes
All concentrations are in percent by weight.
First Aid Measures
Emergency procedures for chemical exposure incidents
Move to fresh air. Call a physician if symptoms develop or persist.
Wash off with soap and water. Get medical attention if irritation develops and persists.
Rinse with water. Remove contact lenses, if present and easy to do. Get medical attention if irritation develops and persists.
Rinse mouth. Get medical attention if symptoms occur.
Medical Treatment
Provide general supportive measures and treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2).
Do not use water jet as an extinguisher, as this will spread the fire.
Thermal decomposition may produce smoke, oxides of carbon and lower molecular weight organic compounds whose composition have not been characterised.
Move containers from fire area if you can do so without risk. Use standard firefighting procedures and consider the hazards of other involved materials.
Firefighter Protection
Move containers from fire area if you can do so without risk. Use standard firefighting procedures and consider the hazards of other involved materials.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Wear appropriate protective equipment and clothing during clean-up. Do not breathe mist/vapours. Ensure adequate ventilation.
Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water.
Avoid discharge into drains, water courses or onto the ground.
Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.
Materials: absorbent material (e.g. cloth, fleece)
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Wear appropriate personal protective equipment.
Store locked up. Store in tightly closed container. Store away from incompatible materials (see section 10 of the SDS).
Observe good industrial hygiene practices.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.
Wear suitable gloves tested to EN374. Neoprene, butyl rubber, nitrile or Viton gloves are recommended. Full contact: Use gloves classified protection index 6 with breakthrough time of 480 minutes. Minimum glove thickness 0.38 mm.
Chemical respirator with organic vapour cartridge and full facepiece. Eye protection should meet standard EN 166.
Chemical respirator with organic vapour cartridge and full facepiece.
Wash hands thoroughly after handling. Use of an impervious apron is recommended.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. Fume scrubbers, filters or engineering modifications to the process equipment may be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
The product is stable and non-reactive under normal conditions of use, storage and transport.
No dangerous reaction known under conditions of normal use.
Contact with incompatible materials.
Strong acids. Strong oxidising agents. Nitrates. Peroxides. Chlorates.
At elevated temperatures: Ketones. Aldehydes.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1. Toxicity
12.1. Toxicity
12.1. Toxicity
12.1. Toxicity
12.2. Persistence and degradability
12.3. Bioaccumulative potential
12.4. Mobility in soil
12.5 Results of PBT and vPvB assessment
The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.
12.6. Endocrine disrupting properties
The mixture does not contain any substances having endocrine disrupting properties with respect to the environment at a concentration equal to or greater than 0.1% by weight.
12.7. Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of in accordance with local regulations. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe manner (see: Disposal instructions).
Collect and reclaim or dispose in sealed containers at licensed waste disposal site. Dispose of contents/container in accordance with local/regional/national/international regulations.
Waste Codes
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The product is classified and labelled in accordance with Regulation (EC) 1272/2008 (CLP Regulation) as amended. This Safety Data Sheet complies with the requirements of Regulation (EC) No 1907/2006, as amended.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Havoline XLI (CL00)?
The signal word is danger.
What is the physical form of Havoline XLI (CL00)?
Havoline XLI (CL00) is a liquid. with colourless. color. It has mild. odor.
What is Havoline XLI (CL00) used for?
Corrosion inhibitor for cooling systems.
What are the hazard statements for Havoline XLI (CL00)?
This substance has 1 hazard statement:
- H360D: May damage the unborn child.
What is the melting point of Havoline XLI (CL00)?
The melting point is -5 °C (23 °F) (Typical) and the boiling point is 100 °C (212 °F) (Estimated).