Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Havoline ProDS V SAE 5W-30
Product Code
804038

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Passenger Car Motor Oil

Manufacturers & Suppliers

C

Chevron Products UK Limited

national supplier

1 Westferry Circus, Canary Wharf, London E14 4HA, United Kingdom

Emergency Contacts

Transportation Emergency Response

0044/(0)18 65 407333

CHEMTREC

+1 703 527 3887

Chevron Emergency Information Center

+1 510 231 0623

24 hours

Emergency Contact

0044/(0)18 65 407333

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Distillates, hydrotreated heavy paraffinic EC: 265-157-1 64742-54-7 25 - 50% No
Lubricating oils, hydrotreated C15-30, neutral oil-based EC: 276-737-9 72623-86-0 2.5 - 10% Yes
Lubricating oils, petroleum, C20-50, hydrotreated neutral oil-based EC: 276-738-4 72623-87-1 2.5 - 10% Yes
Zinc alkyl dithiophosphate EC: 272-028-3 68649-42-3 0.3 - 2.5% Yes
Distillates, solvent dewaxed light paraffinic EC: 265-159-2 64742-56-9 0.1 - 2.5% No
Distillates, solvent-dewaxed heavy paraffinic EC: 265-169-7 64742-65-0 0.1 - 2.5% Yes
Paraffin oils (petroleum), catalytic dewaxed heavy EC: 265-174-4 64742-70-7 0.1 - 2.5% No

In accordance with reference IP 346/92: "DMSO Extraction Method", we have determined that the base oils used in this preparation contain <3% DMSO extract and are not carcinogenic. Internally derived Specific Concentration Limit's (SCL) of C>2% or C>4% have been established for ZnDTPs dependent on the product type they are present in.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If exposed to excessive levels of material in the air, move the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.

Symptoms: May cause respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include coughing and difficulty breathing.

Skin contact

Remove clothing and shoes if contaminated. To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly clean before reuse.

Symptoms: Contact with the skin is not expected to be harmful.

Eye contact

Remove contact lenses, if worn, and flush eyes with water.

Symptoms: Not expected to cause prolonged or significant eye irritation.

Ingestion

Do not induce vomiting. As a precaution, get medical advice.

Symptoms: Not expected to be harmful if swallowed.

Immediate Medical Attention

Get medical attention if coughing or respiratory discomfort occurs. As a precaution, get medical advice if ingested.

Medical Treatment

Not applicable.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.

Specific hazards

A complex mixture of airborne solids, liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved when this material undergoes combustion.

Instructions

For fires involving this material, do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.

Firefighter Protection

Do not enter any enclosed or confined fire space without proper protective equipment, including self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Observe all relevant local and international regulations. Keep out unnecessary and unprotected personnel. Persons entering the contaminated area to correct the problem or to determine whether it is safe to resume normal activities must comply with all instructions in the Exposure Controls/PersonalProtection section.

Environmental

Stop the source of the release if you can do it without risk. Contain release to prevent further contamination of soil, surface water or groundwater.

Cleanup methods

Clean up spill as soon as possible, observing precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-combustible absorbent materials or pumping.

Materials: non-combustible absorbent materials

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not get in eyes, on skin, or on clothing. Do not taste or swallow. Wash thoroughly after handling.

Storage

Not Applicable

Hygiene

Wash thoroughly after handling.

Fire prevention

Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use in a well-ventilated area.

Hands

Using chemical PPE depends upon operations conducted and may include chemical gloves. Refer to PPE manufacturers to obtain breakthrough time information to determine how long PPE can be used before it needs to be replaced. Chemical Glove Material: Butyl (Thickness: 0.7 mm, Typical Breakthrough Time: 120 minutes); Nitrile (Thickness: 0.8 mm, Typical Breakthrough Time: 240 minutes); Viton Butyl (Thickness: 0.3 mm, Typical Breakthrough Time: 240 minutes).

Eyes

Wear protective equipment to prevent eye contact. Selection of protective equipment may include safety glasses, chemical goggles, face shields, or a combination depending on the work operations conducted.

Respiratory

A site-specific risk assessment should be conducted by an Occupational Hygienist or a Safety Professional to determine the type and use of respiratory protective equipment. When a site-specific risk assessment determines that respiratory protection is required, use an approved respirator such as: Air purifying respirator - If airborne concentration limits exceed the applicable occupational exposure limit, but are below the maximum use concentration. Vapors only: organic vapor cartridge (filter type A3 per EN 529:2005). Vapors and particulates (including generated mists): both an organic vapor cartridge & particulate filter (AP3 filter per EN 529:2005). Refer to respirator manufacturers to obtain service life of cartridge / filter. Positive pressure air-supplying respirator - If airborne concentration limits exceed the maximum use concentration offered from an air purifying respirator. Refer to EN 529:2005, USA OSHA 1910.134, and/or other applicable local/regional/national/international standards for regulatory requirements.

Skin/Body

Wear chemical personal protective equipment (PPE) to prevent skin contact. Selection of chemical protective clothing should be performed by an Occupational Hygienist or Safety Professional and be based upon applicable standards (ASTM F739 or EN 374). Using chemical PPE depends upon operations conducted and may include chemical gloves, boots, chemical apron, chemical suit, and complete facial protection.

Environmental

See relevant Community environmental protection legislation or the Annex, as applicable.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Brown to yellow
Colour
Brown to yellow
Colour Intensity
---
Form
---
Odor
Petroleum odor
Odor Threshold
No data available
Ph
Not Applicable
Melting Point
No data available
Boiling Point
No data available
Flash Point
(Cleveland Open Cup) 236 °C (457 °F) (Typical)
Freezing Point
No data available
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
No data available
Vapor Pressure
No data available
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.8518 kg/l @ 15°C (59°F) (Typical)
Flammability
Not Applicable
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
No data available
Decomposition Temperature
No data available
Solubility
Soluble in hydrocarbons; insoluble in water
Partition Coefficient
No data available
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
66.05 mm2/s @ 40°C (104°F) (Typical)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Not applicable

Incompatible

Not applicable

Decomposition

None known (None expected)

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

This material is not expected to be harmful to aquatic organisms. The product has not been tested. The statement has been derived from the properties of the individual components.

12.2 Persistence and degradability

This material is not expected to be readily biodegradable. The product has not been tested. The statement has been derived from the properties of the individual components.

12.3 Bioaccumulative potential

Bioconcentration Factor: No Data Available Partition coefficient n-octanol/water (logarithmic value): No data available

12.4 Mobility in soil

No data available.

12.5 Results of PBT and vPvB assessment

This material does not meet the criteria for PBT or vPvB.

12.6 Endocrine Disrupting Properties

This mixture does not contain any substances that are assessed as having endocrine disrupting properties.

12.7 Other adverse effects

No other adverse effects identified.

12.1 Toxicity

Acute Toxicity: Zinc alkyl dithiophosphate†† | Test Qualifier: EC50 (growth rate) Test Result: 2.1 mg/l (WAF) Species: Algae Duration:72 hour(s) * read-across data from similar material. Long-term Toxicity: Zinc alkyl dithiophosphate†† | No test data available

12.2 Persistence and degradability

No data available

12.3 Bioaccumulative potential

No data available

12.4 Mobility in soil

No data available

12.5 Results of PBT and vPvB assessment

No data available

12.6 Endocrine disrupting properties

No data available

12.7 Other adverse effects

No data available

12.2 Persistence and degradability

Biodegradation: Not applicable

Bioaccumulative Potential

Zinc alkyl dithiophosphate†† No test data available

No test data available

12.5 Results of PBT and vPvB assessment

This material does not meet the criteria for PBT or vPvB.

The material does not meet the criteria for PBT or vPvB.

12.1 Toxicity

Component Information: Acute Toxicity: Distillates, hydrotreated heavy paraffinic: Based on available data, the classification criteria are not met Lubricating oils, hydrotreated C15-30, neutral oil-based: Based on available data, the classification criteria are not met Lubricating oils, petroleum, C20-50, hydrotreated neutral oil-based: Based on available data, the classification criteria are not met Zinc alkyl dithiophosphate††: Test Qualifier: EC50 (growth rate) Test Result: 2.1 mg/l (WAF) Species: Algae Duration:72 hour(s) * read-across data from similar material Paraffin oils (petroleum), catalytic dewaxed heavy: Based on available data, the classification criteria are not met Distillates, solvent dewaxed light paraffinic: Based on available data, the classification criteria are not met Distillates, solvent-dewaxed heavy paraffinic: Based on available data, the classification criteria are not met Long-term Toxicity: Distillates, hydrotreated heavy paraffinic: Based on available data, the classification criteria are not met Lubricating oils, hydrotreated C15-30, neutral oil-based: Based on available data, the classification criteria are not met Lubricating oils, petroleum, C20-50, hydrotreated neutral oil-based: Based on available data, the classification criteria are not met Zinc alkyl dithiophosphate††: No test data available Paraffin oils (petroleum), catalytic dewaxed heavy: Based on available data, the classification criteria are not met Distillates, solvent dewaxed light paraffinic: Based on available data, the classification criteria are not met Distillates, solvent-dewaxed heavy paraffinic: Based on available data, the classification criteria are not met

12.2 Persistence and degradability

Biodegradation: Distillates, hydrotreated heavy paraffinic: Based on available data, the classification criteria are not met Lubricating oils, hydrotreated C15-30, neutral oil-based: Based on available data, the classification criteria are not met Lubricating oils, petroleum, C20-50, hydrotreated neutral oil-based: Based on available data, the classification criteria are not met Zinc alkyl dithiophosphate††: Not applicable Paraffin oils (petroleum), catalytic dewaxed heavy: Based on available data, the classification criteria are not met Distillates, solvent dewaxed light paraffinic: Based on available data, the classification criteria are not met Distillates, solvent-dewaxed heavy paraffinic: Based on available data, the classification criteria are not met

12.3 Bioaccumulative potential

Bioaccumulative Potential: Distillates, hydrotreated heavy paraffinic: Based on available data, the classification criteria are not met Lubricating oils, hydrotreated C15-30, neutral oil-based: Based on available data, the classification criteria are not met Lubricating oils, petroleum, C20-50, hydrotreated neutral oil-based: Based on available data, the classification criteria are not met Zinc alkyl dithiophosphate††: No test data available Paraffin oils (petroleum), catalytic dewaxed heavy: Based on available data, the classification criteria are not met Distillates, solvent dewaxed light paraffinic: Based on available data, the classification criteria are not met Distillates, solvent-dewaxed heavy paraffinic: Based on available data, the classification criteria are not met

12.6 Endocrine Disrupting Properties

This mixture does not contain any substances that are assessed as having endocrine disrupting properties.

12.7 Other adverse effects

No other adverse effects identified.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil recycling or disposal.

Disposal

Contact your sales representative or local environmental or health authorities for approved disposal or recycling methods.

Waste Codes

13 02 06 EWC
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

No components of this material were found on the regulatory lists searched (EU Directive 92/85/EEC, 2012/18/EU, 98/24/EC, 2004/37/EC, EC No. 689/2008, EC No. 850/2004, REACH Annex XVII, REACH Annex XIV).

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Havoline ProDS V SAE 5W-30?

The signal word is no signal word.

What is the physical form of Havoline ProDS V SAE 5W-30?

Havoline ProDS V SAE 5W-30 is a liquid appearing as brown to yellow with brown to yellow color. It has petroleum odor odor.

What is the solubility of Havoline ProDS V SAE 5W-30?

Soluble in hydrocarbons; insoluble in water

What is Havoline ProDS V SAE 5W-30 used for?

Passenger Car Motor Oil

What is the melting point of Havoline ProDS V SAE 5W-30?

The melting point is No data available and the boiling point is No data available.