NextSDS Logo
GA

GAZ DE PETROLE LIQUEFIE

NO SIGNAL WORD Gaz liqufi sous pression SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
GAZ DE PETROLE LIQUEFIE
Product Form
Liquefied petroleum gas

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Combustible pour utilisations domestiques, industriels et agricoles, carburant pour moteurs combustion interne, ptrochimiques, propulsifs, expansifs, rfrigrants.

Overview

GAZ DE PETROLE LIQUEFIE commonly used combustible pour utilisations domestiques, industriels et agricoles, carburant pour moteurs combustion interne, ptrochimiques, propulsifs, expansifs, rfrigrants..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Press. Gas H280
Flam. Gas Category 1 H220

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS04 GHS Hazard Pictogram: Compressed gas hazard - Pressurized gases that may explode if heated

GHS04

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

MAGMA Gas Technology company logo - Safety Data Sheet supplier organization

MAGMA Gas Technology

manufacturer

๐Ÿ“

Scheibeekstraat 27-29 | 1540 Herne | Belgium

๐ŸŒ

BE

๐Ÿ“ 

+32 2 356 21 78

PROF PRAXIS NV/SA

distributor

๐Ÿ“

Scheibeekstraat 27-29 1540 Herne - Belgique

๐ŸŒ

BE

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

0032 2 356 37 52

๐ŸŒ

BE

๐Ÿ•’

disponible de 8h30 17h00

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Le Gaz de Ptrole Liqufie (GPL) driv de la distillation et production du ptrole, de puits dextraction pour sparation du gaz naturel, de certains processus chimiques. Le GPL est compos principalement dun mlange de propane (environ 10%), de butane (environ 70%) et de propylne (environ 20%). Le GPL peut contenir de petites quantits dautres hydrocarbures satures (thane, isobutane et pentane) ou insaturs (butnes) qui ne prsentent pas de dangers autres que ceux caractristiques de la substance indiqus au point 2.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbures, C3-4, GAS de PETROLE
EC: 270-681-9
68476-40-4 Not specified โœ“ Non-hazardous
propane N/A Not specified โœ“ Non-hazardous
butane N/A Not specified โœ“ Non-hazardous
propylne N/A Not specified โœ“ Non-hazardous

Composition Notes

Ne contient pas de 1.3 butadine en quantit suprieure 0,1%. Si destin la combustion, il contient un produit dnaturant, en mesure de 4 g tous les 100 kg de GPL, comme tabli par le D.M. 21.3.1996 du Ministre des Finances. En outre, le Butane commercial dois contenir un produit odorant afin de rendre dtectable la prsence dj des concentrations infrieures au L.I.E., conformment la L. 6.12.1971, n 1083. Lodorisation du gaz doit tre ralise selon la norme UNI 7133 (gaz combustibles) et selon la norme UNI EN 589 (GPL pour auto-traction). Les susdits produits sont dans tous les cas prsents des concentrations infrieures aux limites prescrites.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

loigner la victime de laccident de la zone pollue ; soumettre immdiatement la victime des soins mdicaux dans le cas o elle prsente des symptmes attribus linhalation de vapeurs ; pratiquer la respiration artificielle dans le cas o la victime de laccident a des difficults srieuses respirer.

๐Ÿ–๏ธ Skin Contact

Rincer abondamment avec de leau la zone cutane concerne ; enlever avec soin les vtements et mouiller abondamment la partie lse avec de leau. recourir au mdecin pour le traitement dventuelles lsions dues au froid.

๐Ÿ‘๏ธ Eye Contact

irriguer abondamment leau les paupires bien ouvertes ; recourir au plus vite un mdecin spcialiste.

๐Ÿšจ Immediate Medical Attention Required

soumettre immdiatement la victime des soins mdicaux dans le cas o elle prsente des symptmes attribus linhalation de vapeurs ; recourir au mdecin pour le traitement dventuelles lsions dues au froid ; recourir au plus vite un mdecin spcialiste.

Medical Treatment

pratiquer la respiration artificielle dans le cas o la victime de laccident a des difficults srieuses respirer.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Gaz liqufi sous pression
Critical Property
๐Ÿ“Š Physical State Data
gas
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
incolore
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Caractristique si odoris pour usage combustion ou auto-traction (1)
๐Ÿ“Š Odor Threshold
0,2 0,4% avec odorisant
๐Ÿงช Ph
Not available
๐ŸงŠ Melting Point
de -138 (Butane) -187 (Propane)
Critical Property
๐Ÿ’จ Boiling Point
de - 42 (propane) - 0,5 (butane)
Critical Property
๐Ÿ”ฅ Flash Point
de -104 (propane) - 60 (butane)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
7,5 (propane) - 1,8 (butane), (mthode ASTM D 1267)
๐Ÿ“Š Vapor Density
De 1,86 (propane) 2,45 (butane) Kg/m [3]
๐Ÿ“Š Relative Density
De 1,5 (propane) a 2,0 (butane)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
de 0,508 (propane) 0,584 (butane), Kg/l: (mthode ASTM D 1657)
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
8,41 11
๐Ÿ“Š Lower Explosive Limit
1,86 2,27
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
de 468 (propane) 405 (butane)
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Mthanol, thanol, ther
๐Ÿ“Š Partition Coefficient
Not available
๐Ÿ“Š Solubility In Water
ngligeable
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Ne corrode pas les matriaux mtalliques
๐Ÿ“Š Dynamic Viscosity
17x10 [-5] (butane)
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿงค Hand Protection

Utiliser des gants et disposer de gants isolation thermique avec protection de lavant-bras ( la mousquetaire) pour les ventuelles urgences

๐Ÿ‘๏ธ Eye Protection

Utiliser des lunettes de scurit, visires, crans faciaux comme protection contre les claboussements de liquide .

๐Ÿ˜ท Respiratory Protection

En cas dinterventions dans des lieux avec prsence de gaz, utiliser des auto-respirateurs

๐Ÿฆบ Skin/Body Protection

Utiliser des vtements antistatiques complets, capables de couvrir les membres suprieurs et infrieurs.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN2037

๐Ÿ“ฆ Proper Shipping Name

RECEPTACLES, PETIT, CONTENANT GAZ (CARTOUCHES DE GAZ) SANS VALVE, NON RECHARGEABLE

โš ๏ธ Transport Hazard Class

Classe 2

๐Ÿ“‹ Packing Group

Non applicable

๐Ÿš› ADR Transport Precautions

Avant de commencer le transport des bouteilles de gaz: Assurez-vous que les rcipients sont fermement arrims; Assurez-vous que la valve est bien ferme; Assurez-vous que le bouchon est correctement appliqu la sortie du robinet

๐Ÿšข IMDG Maritime Transport Precautions

Avant de commencer le transport des bouteilles de gaz: Assurez-vous que les rcipients sont fermement arrims; Assurez-vous que la valve est bien ferme; Assurez-vous que le bouchon est correctement appliqu la sortie du robinet

โœˆ๏ธ IATA Air Transport Precautions

Avant de commencer le transport des bouteilles de gaz: Assurez-vous que les rcipients sont fermement arrims; Assurez-vous que la valve est bien ferme; Assurez-ou que le bouchon est correctement appliqu la sortie du robinet

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for GAZ DE PETROLE LIQUEFIE?

The signal word for this substance is "no signal word".

What is the physical form of GAZ DE PETROLE LIQUEFIE?

GAZ DE PETROLE LIQUEFIE is a gaz liqufi sous pression with incolore color. It has caractristique si odoris pour usage combustion ou auto-traction (1) odor.

What is the solubility of GAZ DE PETROLE LIQUEFIE?

Mthanol, thanol, ther

What is GAZ DE PETROLE LIQUEFIE used for?

Combustible pour utilisations domestiques, industriels et agricoles, carburant pour moteurs combustion interne, ptrochimiques, propulsifs, expansifs, rfrigrants.

What is the melting point of GAZ DE PETROLE LIQUEFIE?

The melting point is de -138 (Butane) -187 (Propane) and the boiling point is de - 42 (propane) - 0,5 (butane).