NextSDS Logo
Safety Data Sheet EN

Metal-Fluid

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Metal-Fluid
Product Code
155800

Regulatory Identifiers

CAS Number
N/A
UFI Code
M5Q0-R0UF-T00V-GHAC

Identified Uses

Washing and cleaning products

Manufacturers & Suppliers

WEICON GmbH & Co. KG logo

WEICON GmbH & Co. KG

manufacturer

Königsberger Str. 255, 48157 Münster, Germany

+49 251 93220

http://www.weicon.de

Emergency Contacts

EMERGENCY CONTACT – UK, UAE, South Africa

++44 1865 407333

24h

EN

TRANSPORT EMERGENCY CONTACT - UK, UAE, South Africa

++44 1865 407333

24h

EN

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P103 Read label before use.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
HIGHLY REFINED BASE OILS EC: 232-455-8 8042-47-5 10% Yes
Alcohols, C16-18 and C18-unsatd., ethoxylated propoxylated EC: 932-102-4 677026-24-3 5% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove victim to fresh air and keep at rest in a position comfortable for breathing.

Symptoms: No specific data.

Skin contact

Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.

Symptoms: No specific data.

Eye contact

Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.

Symptoms: No specific data.

Ingestion

Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.

Symptoms: No specific data.

Immediate Medical Attention

Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be sufficient to control worker exposure to airborne contaminants.

Hands

Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Recommended : 1 - 4 hours (breakthrough time): nitrile rubber ; 4 - 8 hours (breakthrough time): Viton®/butyl rubber

Eyes

Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: safety glasses with side-shields.

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.

Environmental

Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Softening Point
---
Solubility
Soluble in the following materials: cold water and hot water.
Colour Intensity
---
Auto Ignition Temperature
Not applicable.
Voc Content
---
Physical State Data
liquid
Freezing Point
Not available.
Evaporation Rate
Not available.
Appearance
Liquid.
Physical State
Liquid.
Boiling Point
100°C (212ºF)
Molecular Weight
---
Bulk Density
---
Flash Point
Closed cup: >100°℃ (>212ºF)
Relative Density
Not available.
Cloud Point
---
Upper Explosive Limit
Not available.
Form
---
Melting Point
Not available.
Decomposition Temperature
Not available.
Crystallisation Point
---
Lower Explosive Limit
Not available.
Explosive Limits
---
Ph
11.4
Metal Corrosion
---
Solubility In Water
Not available.
Partition Coefficient
Not applicable.
Odor Threshold
Not available.
Vapor Pressure
<table> <tr> <th rowspan="2">Ingredient name</th> <th colspan="3">Vapor Pressure at 20℃</th> <th colspan="3">Vapor pressure at 50℃</th> </tr> <tr> <th>mm Hg</th> <th>kPa</th> <th>Method</th> <th>mm Hg</th> <th>kPa</th> <th>Method</th> </tr> <tr> <td>water</td> <td>23.8</td> <td>3.2</td> <td></td> <td></td> <td></td> <td></td> </tr> <tr> <td>2-aminoethanol</td> <td>0.4</td> <td>0.053</td> <td></td> <td></td> <td></td> <td></td> </tr> <tr> <td>White mineral oil (petroleum)</td> <td>0.08</td> <td>0.011</td> <td>OECD 104</td> <td></td> <td></td> <td></td> </tr> <tr> <td>2,2'-iminodiethanol</td> <td>&lt;0.01</td> <td>&lt;0.0013</td> <td></td> <td></td> <td></td> <td></td> </tr> </table>
Flammability
Not available.
Density
0.94 g/cm3 [20℃ (68ºF)]
Odor
Characteristic.
Dynamic Viscosity
Not available.
State Under Standard Conditions
---
Colour
White.
Solubility In Fat
---
Vapor Density
Not available.
Properties Status
---
Kinematic Viscosity
Not available.
Relative Evaporation Rate
---
Solidification Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

ADR

Transport within user's premises: always transport in closed containers that are upright and secure. Ensure that persons transporting the product know what to do in the event of an accident or spillage.

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Metal-Fluid?

The signal word is no signal word.

What is the physical form of Metal-Fluid?

Metal-Fluid is a liquid. appearing as liquid. with white. color. It has characteristic. odor.

What is the solubility of Metal-Fluid?

Soluble in the following materials: cold water and hot water.

What is Metal-Fluid used for?

Washing and cleaning products

What is the melting point of Metal-Fluid?

The melting point is Not available. and the boiling point is 100°C (212ºF).