NextSDS Logo
Safety Data Sheet EN

Technovit 3040 powder

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Technovit 3040 powder

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Resin for indirect surface testing and impressions

Uses advised against

No further relevant information available.

Manufacturers & Suppliers

K

Kulzer GmbH

manufacturer

Leipziger Straße 2, 63450 Hanau (Germany)

+49 (0)6181 9689-2570 (Wehrheim)

Emergency Contacts

Emergency Contact

+49 (0)6132-84463

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Product based on methacrylate copolymers

For the wording of the listed hazard phrases refer to section 16.

Notes

Dangerous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms.

Skin contact

Instantly wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Rinse out mouth and then drink plenty of water. In case of persistent symptoms consult doctor.

Immediate Medical Attention

No further relevant information available.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water jet. Fight larger fires with water jet or alcohol-resistant foam.

Specific hazards

No further relevant information available.

Firefighter Protection

No special measures required.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Do not allow to enter drainage system, surface or ground water. Do not allow to enter the ground/soil.

Cleanup methods

Collect mechanically.

Materials: suitable containers

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measures required.

Storage

No special requirements.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Protective goggles are recommended.

Respiratory

Not required.

Skin/Body

Light weight protective clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Bulk Density
---
Relative Evaporation Rate
---
Freezing Point
---
Vapor Pressure
Not applicable.
Ph
Not applicable.
Dynamic Viscosity
Not applicable.
Boiling Point
Not determined
Crystallisation Point
---
Properties Status
---
Partition Coefficient
Not determined.
Explosive Limits
---
Softening Point
---
Solubility
---
Vapor Density
Not applicable.
Evaporation Rate
Not applicable.
Colour Intensity
---
Voc Content
---
Solubility In Fat
---
Metal Corrosion
---
Flash Point
Not applicable
State Under Standard Conditions
---
Physical State Data
solid
Kinematic Viscosity
Not applicable.
Flammability
Not determined.
Odor
Odourless
Solidification Point
---
Appearance
Different according to colour
Melting Point
Not determined
Solubility In Water
Insoluble
Molecular Weight
---
Decomposition Temperature
Not determined.
Cloud Point
---
Auto Ignition Temperature
Product is not selfigniting.
Lower Explosive Limit
Not determined.
Upper Explosive Limit
Not determined.
Form
Powder
Density
Not determined
Relative Density
Not determined.
Colour
Different according to colour
Odor Threshold
Not determined.
Physical State
Powder
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used and stored according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Small quantities can be polymerized with the matching system component(s) and the cured solid material can be disposed of with the regular garbage.

Disposal

Small quantities can be polymerized with the matching system component(s) and the cured solid material can be disposed of with the regular garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Void
Shipping Name
Void
Transport Class
Void
Packing Group
Void
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Technovit 3040 powder?

The signal word is no signal word.

What is the physical form of Technovit 3040 powder?

Technovit 3040 powder is a powder appearing as different according to colour with different according to colour color. It has odourless odor.

What is Technovit 3040 powder used for?

Resin for indirect surface testing and impressions

What is the melting point of Technovit 3040 powder?

The melting point is Not determined and the boiling point is Not determined.