Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Technovit 2000 LC
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Resin for metallographic testing
Manufacturers & Suppliers
Kulzer GmbH
manufacturer
Leipziger Straße 2, 63450 Hanau (Germany)
+49 (0)6181 9689-2570
Emergency Contacts
Emergency Contact
+49 (0)6132-84463
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 2-phenoxyethyl methacrylate | 10595-06-9 | 25 - 50% | Yes |
| ethyl methacrylate EC: 202-597-5 | 97-63-2 | 10 - 25% | Yes |
| isobornyl methacrylate EC: 231-403-1 | 7534-94-3 | 5 - 10% | Yes |
| methacrylic acid, monoester with propane-1,2-diol EC: 248-666-3 | 27813-02-1 | 5 - 10% | Yes |
| triethylen glycol dimethacrylate EC: 203-652-6 | 109-16-0 | 1% | Yes |
| ethyl phenyl(2,4,6-trimethylbenzoyl)phosphinate EC: 282-810-6 | 84434-11-7 | 1% | Yes |
| mequinol EC: 205-769-8 | 150-76-5 | 1% | Yes |
For the wording of the listed hazard phrases refer to section 16.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of symptoms.
Instantly rinse with water. If skin irritation continues, consult a doctor.
Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.
Rinse out mouth and then drink plenty of water. In case of persistent symptoms consult doctor.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, sand, extinguishing powder.
Water.
Can form explosive gas-air mixtures. Formation of toxic gases is possible during heating or in case of fire.
Firefighter Protection
No special measures required.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Not required
for small amounts tissues
No special measures required.
Absorb with liquid-binding material
Materials: diatomite, universal binders, for small amounts tissues
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep containers tightly sealed.
Store in cool, dry conditions in well sealed containers.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Not necessary with efficient local exhaust.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. If skin contact cannot be avoided, protective gloves are recommended to avoid possible sensitization. Solvent resistant gloves. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: Butyl rubber, BR, Nitrile rubber, NBR
Safety glasses
If exposition to vapours is possible, use breathing protective mask (filter A).
Light weight protective clothing
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used and stored according to specifications.
No further relevant information available.
No dangerous reactions known
No further relevant information available.
No further relevant information available.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.1 Toxicity
12.2 Persistence and degradability
12.3 Bioaccumulative potential
12.4 Mobility in soil
12.5 Results of PBT and vPvB assessment
Not applicable.
12.6 Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Must not be disposed of together with household garbage.
Must not be disposed of together with household garbage.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 2277
- Shipping Name
- ETHYL METHACRYLATE, STABILIZED mixture
- Transport Class
- 3
- Packing Group
- II
Warning: Flammable liquids.
Warning: Flammable liquids.
Warning: Flammable liquids.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Technovit 2000 LC?
The signal word is danger.
What is the physical form of Technovit 2000 LC?
Technovit 2000 LC is a liquid with colourless color. It has characteristic odor.
What is Technovit 2000 LC used for?
Resin for metallographic testing
What are the hazard statements for Technovit 2000 LC?
This substance has 5 hazard statements:
- H225: Highly flammable liquid and vapour.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H412: Harmful to aquatic life with long lasting effects.
What is the melting point of Technovit 2000 LC?
The melting point is Not determined and the boiling point is Not determined.