NextSDS Logo
Te

Technovit Universal Liquid

DANGER SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Technovit Universal Liquid

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Resin for indirect surface testing and impressions

Overview

Technovit Universal Liquid is a fluid, colourless substance commonly used resin for indirect surface testing and impressions.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Skin Irr. Category 2 H315
Skin Sens. Category 1 H317
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H335: May cause respiratory irritation.

Precautionary Statements

  • P210: Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
  • P260: Do not breathe dust/fume/gas/mist/vapours/spray.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P243: Take precautionary measures against static discharge.
  • P370+P378: In case of fire: Use for extinction: CO2, sand, extinguishing powder.
  • P403: Store in a well-ventilated place.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Kulzer GmbH

manufacturer

๐Ÿ“

Leipziger Strae 2, 63450 Hanau (Germany)

๐ŸŒ

DE

๐Ÿ“ž

+49 (0)6181 9689-2570

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 (0)6132-84463

๐ŸŒ

DE

๐Ÿ•’

24-Hour-Number

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

Product based on methacrylates

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
methyl methacrylate
EC: 201-297-1
80-62-6 90% โš ๏ธ Hazardous
N,N-dimethyl-p-toluidine
EC: 202-805-4
99-97-8 5% โš ๏ธ Hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of symptoms.

๐Ÿ–๏ธ Skin Contact

Instantly wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Rinse out mouth and then drink plenty of water. Instantly call for doctor. In case of persistent symptoms consult doctor.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
Not available
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Fluid, Colourless
๐ŸŽจ Colour
Colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Fluid
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not determined.
๐ŸงŠ Melting Point
Not determined
Critical Property
๐Ÿ’จ Boiling Point
100 C
Critical Property
๐Ÿ”ฅ Flash Point
10 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
47 hPa
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
0.940 g/cm
Critical Property
๐Ÿ”ฅ Flammability
Not applicable.
๐Ÿ“Š Upper Explosive Limit
12.5 Vol %
๐Ÿ“Š Lower Explosive Limit
2.1 Vol %
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
430 C
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Not miscible or difficult to mix
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
911.9 g/l / 7.61 lb/gl (USA), 911.9 g/l (EU)
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
1 mPas
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

If skin contact cannot be avoided, protective gloves are recommended to avoid possible sensitization. Solvent resistant gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: Butyl rubber, BR; Fluorocarbon rubber (Viton); Nitrile rubber, NBR; Chloroprene rubber, CR

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

Not neccessary with efficient local exhaust. If exposition to vapours is possible, use breathing protective mask (filter A).

๐Ÿฆบ Skin/Body Protection

Light weight protective clothing

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1247

๐Ÿ“ฆ Proper Shipping Name

METHYL METHACRYLATE MONOMER, STABILIZED, solution

โš ๏ธ Transport Hazard Class

3 Flammable liquids.

๐Ÿ“‹ Packing Group

II

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Technovit Universal Liquid?

The signal word for this substance is "danger".

What is Technovit Universal Liquid used for?

Resin for indirect surface testing and impressions

What are the hazard statements for Technovit Universal Liquid?

This substance has 4 hazard statements: H225: Highly flammable liquid and vapour. H315: Causes skin irritation. H317: May cause an allergic skin reaction. H335: May cause respiratory irritation.

What is the melting point of Technovit Universal Liquid?

The melting point is Not determined and the boiling point is 100 C.