Technovit Universal Liquid

DANGER Fluid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Technovit Universal Liquid

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Resin for indirect surface testing and impressions

Overview

Technovit Universal Liquid commonly used resin for indirect surface testing and impressions.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Liq. Category 2 H225
Skin Irrit. Category 2 H315
Skin Sens. Category 1 H317
STOT SE Category 3 H335

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Highly flammable liquid and vapour.
  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H335: May cause respiratory irritation.

Precautionary Statements

  • P210: Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
  • P243: Take precautionary measures against static discharge.
  • P260: Do not breathe dust/fume/gas/mist/vapours/spray.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P370+P378: In case of fire: Use for extinction: CO2, sand, extinguishing powder.
  • P403: Store in a well-ventilated place.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Kulzer GmbH

manufacturer

Leipziger Strae 2, 63450 Hanau (Germany)

DE

+49 (0)6181 9689-2570

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+49 (0)6132-84463

DE

24-Hour-Number

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

Mixtures

General Composition

Product based on methacrylates

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Mthacrylate de mthyle
EC: 201-297-1
80-62-6 90% Hazardous
N,N-Dimethyl-p-toludine
EC: 202-805-4
99-97-8 5% Hazardous

Additional Information

For the wording of the listed hazard phrases refer to section 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Supply fresh air; consult doctor in case of symptoms.

Skin Contact

Instantly wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

Eye Contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult doctor.

Ingestion/Swallowing

Rinse out mouth and then drink plenty of water. Instantly call for doctor. In case of persistent symptoms consult doctor.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
Fluid
Critical Property
Physical State Data
liquid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
Colourless
Colour Intensity
Not available
Form
Fluid
Odor
Characteristic
Odor Threshold
Not determined.
Ph
Not determined.
Melting Point
Not determined
Critical Property
Boiling Point
100 C
Critical Property
Flash Point
10 C
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not determined.
Vapor Pressure
47 hPa
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
Not available
Density
0.940 g/cm
Critical Property
Flammability
Not applicable.
Upper Explosive Limit
12.5 Vol %
Lower Explosive Limit
2.1 Vol %
Explosive Limits
Not available
Auto Ignition Temperature
430 C
Decomposition Temperature
Not determined.
Solubility
Not available
Partition Coefficient
Not determined.
Solubility In Water
Not miscible or difficult to mix
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
911.9 g/l / 7.61 lb/gl
Metal Corrosion
Not available
Dynamic Viscosity
1 mPas
Kinematic Viscosity
Not determined.
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

No further data; see item 7.

Hand Protection

If skin contact cannot be avoided, protective gloves are recommended to avoid possible sensitization. Solvent resistant gloves. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. For the permanent contact of a maximum of 15 minutes gloves made of the following materials are suitable: Butyl rubber, BR; Fluorocarbon rubber (Viton); Nitrile rubber, NBR; Chloroprene rubber, CR

Eye Protection

Safety glasses

Respiratory Protection

Not neccessary with efficient local exhaust. If exposition to vapours is possible, use breathing protective mask (filter A).

Skin/Body Protection

Light weight protective clothing

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

1247

Proper Shipping Name

METHYL METHACRYLATE MONOMER, STABILIZED, solution

Transport Hazard Class

3 Flammable liquids.

Packing Group

II

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Technovit Universal Liquid?

The signal word for this substance is "danger".

What is the physical form of Technovit Universal Liquid?

Technovit Universal Liquid is a fluid with colourless color. It has characteristic odor.

What is Technovit Universal Liquid used for?

Resin for indirect surface testing and impressions

What are the hazard statements for Technovit Universal Liquid?

This substance has 4 hazard statements: H225: Highly flammable liquid and vapour. H315: Causes skin irritation. H317: May cause an allergic skin reaction. H335: May cause respiratory irritation.

What is the melting point of Technovit Universal Liquid?

The melting point is Not determined and the boiling point is 100 C.