Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Molecular sieve 0.3 nm
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Laboratory chemicals. Adsorbents.
Manufacturers & Suppliers
Metrohm AG
manufacturer
Ionenstrasse 9100 Herisau Schweiz
+41 (0)71 353 85 85
www.metrohm.com
Metrohm Belgium nv
Drabstraat 198 2550 Kontich Belgium
+32 (0)3 281 33 31
Emergency Contacts
Antigifcentrum (Centre Antipoisons)
+32 (0) 70 245 245
every day, 24 hours
GBK GmbH
+ 49 (0)6132-84463
24 h
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment, are PBTs, vPvBs or Substances of equivalent concern, or have been assigned a workplace exposure limit and hence require reporting in this section.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| crystalline silica EC: 238-878-4 | 14808-60-7 | 10% | No |
Notes
See Section 16 for the full text of the H statements declared above. Specific Conc. Limits, M-factors and ATEs. Occupational exposure limits, if available, are listed in Section 8.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove victim to fresh air and keep at rest in a position comfortable for breathing. Get medical attention if symptoms occur.
Symptoms: No known significant effects or critical hazards. No specific data.
Flush contaminated skin with plenty of water. Remove contaminated clothing and shoes. Get medical attention if symptoms occur.
Symptoms: No known significant effects or critical hazards. No specific data.
Immediately flush eyes with plenty of water, occasionally lifting the upper and lower eyelids. Check for and remove any contact lenses. Get medical attention if irritation occurs.
Symptoms: No known significant effects or critical hazards. No specific data.
Wash out mouth with water. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Do not induce vomiting unless directed to do so by medical personnel. Get medical attention if symptoms occur.
Symptoms: No known significant effects or critical hazards. No specific data.
Immediate Medical Attention
Contact poison treatment specialist immediately if large quantities have been ingested or inhaled.
Medical Treatment
Treat symptomatically. No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Membrane filter, 0.22 micron nitrocellulose / Ø 47 mm
---
Silica gel FIA coarse 0,071-0,63 mm, 1
---
Silica gel 60 (0.063-0.200 mm) for column chromatography (70-230 mesh ASTM)
CAS: 7631-86-9
Molsiv Adsorbents 13X HP 10x20
---
Molsiv Adsorbents 4A-DG 1/16
---
Fumed Silicia Suspension 0,2 μm anhydrous
---
Silica gel
CAS: 112926-00-8
Sodium molybdenum oxide
CAS: 7631-95-0
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Good general ventilation should be sufficient to control worker exposure to airborne contaminants.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Recommended: Wear suitable gloves tested to EN374. butyl rubber, nitrile rubber, chloroprene rubber.
Safety eyewear complying with an approved standard should be used when a risk assessment indicates this is necessary to avoid exposure to liquid splashes, mists, gases or dusts. If contact is possible, the following protection should be worn, unless the assessment indicates a higher degree of protection: Wear safety glasses with side protection in accordance with EN 166.
Based on the hazard and potential for exposure, select a respirator that meets the appropriate standard or certification. Respirators must be used according to a respiratory protection program to ensure proper fitting, training, and other important aspects of use. Recommended: Particle filter device (EN 143). Filter type: P1 / FFP1.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated.
- Shipping Name
- Not regulated.
- Transport Class
- Not regulated.
- Packing Group
- Not regulated.
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Molecular sieve 0.3 nm?
The signal word is no signal word.
What is the physical form of Molecular sieve 0.3 nm?
Molecular sieve 0.3 nm is a solid. with dark brown. color. It has odourless. odor.
What is Molecular sieve 0.3 nm used for?
Laboratory chemicals. Adsorbents.
What is the melting point of Molecular sieve 0.3 nm?
The melting point is Not available. and the boiling point is Not available..