NextSDS Logo
RE

RESION MEKP Hardener

DANGER Liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
RESION MEKP Hardener
Product Code
PR91

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
RT10-D0UY-8003-KC00

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
Curing agent for resins
Uses Advised Against
None known.

Overview

RESION MEKP Hardener commonly used curing agent for resins.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Self-react. H242
Acute Tox. Category 4 H302
Skin Corr. Category 1B H314
Eye Dam. Category 1 H318

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H242: Heating may cause a fire.
  • H302: Harmful if swallowed.
  • H314: Causes severe skin burns and eye damage.

Precautionary Statements

  • P101: If medical advice is needed, have product container or label at hand.
  • P102: Keep out of reach of children.
  • P260: Do not breathe vapour/mist.
  • P280: Wear face protection/protective gloves.
  • P303+P361+P353: IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water .
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local regulation

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Polyestershoppen BV

national supplier

๐Ÿ“

Oostbaan 680 2841 ML Moordrecht Netherlands

๐ŸŒ

NL

๐Ÿ“ž

+31 85 0220090

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

The National Poisons Information Service

๐Ÿ“ž

111

๐ŸŒ

GB

๐Ÿ•’

24 h service

๐Ÿ’ก

See section 4 "First aid measures".

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2-Butanone, peroxide
EC: 700-954-4
1338-23-4 25-40% โš ๏ธ Hazardous
Hydrogen Peroxide
EC: 231-765-0
7722-84-1 1-3% โš ๏ธ Hazardous

Additional Information

According to EC-Regulation 1907/2006 (REACH), annex II, including changes implemented by EC-Regulation 2020/878. See full text of H-phrases in section 16. Occupational exposure limits are listed in section 8, if these are available.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Upon breathing difficulties or irritation of the respiratory tract: Bring the person into fresh air and stay with him/her.

Symptoms:

Upon breathing difficulties or irritation of the respiratory tract. Inhaled vapour or aerosols may produce adverse effects to lungs, irritations and burns in the respiratory organs as well as coughing.

๐Ÿ–๏ธ Skin Contact

Flush exposed area with water for a long time - at least 30 minutes. It may be necessary to flush for several hours. Use a comfortable water temperature (20-30 ). Contact Poison Information/doctor/hospital for further advice on follow-up and treatment. Upon irritation: rinse with water. In the event of continued irritation, seek medical assistance.

Symptoms:

This product contains substances with skin corrosive properties. Dermal contact cause irreversible effects.

๐Ÿ‘๏ธ Eye Contact

If in eyes: Flush eyes with plenty of water or salt water (20-30 ) for at least 30 minutes and continue until irritation stops. Remove contact lenses. Make sure you flush under the upper and lower eyelids. Seek medical assistance immediately and continue flushing during transport.

Symptoms:

contact with the eye cause irreversible effects.

๐Ÿฝ๏ธ Ingestion/Swallowing

In the case of ingestion, contact a doctor immediately. If the person is conscious, give them water. DO NOT try to induce vomiting unless this is recommended by a doctor. Hold head facing down to prevent vomit from returning to the mouth and throat. Prevent shock by keeping the injured person warm and calm. Initiate immediate resuscitation if breathing stops. If unconscious, roll the injured person into recovery position. Call an ambulance.

๐Ÿšจ Immediate Medical Attention Required

IF exposed or concerned: Get immediate medical advice/attention.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Characteristic
๐Ÿ“Š Odor Threshold
Characteristic
๐Ÿงช Ph
Testing not relevant or not possible due to the nature of the product.
๐ŸงŠ Melting Point
Testing not relevant or not possible due to the nature of the product.
Critical Property
๐Ÿ’จ Boiling Point
Testing not relevant or not possible due to the nature of the product.
Critical Property
๐Ÿ”ฅ Flash Point
>80
Critical Property
๐Ÿ“Š Freezing Point
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Softening Point
Does not apply to liquids.
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1.1
Critical Property
๐Ÿ”ฅ Flammability
The material is ignitable.
๐Ÿ“Š Upper Explosive Limit
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Lower Explosive Limit
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Decomposition Temperature
Testing not relevant or not possible due to the nature of the product.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Solubility In Water
Insoluble
๐Ÿ“Š Solubility In Fat
Testing not relevant or not possible due to the nature of the product.
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
15 mPa.s
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ground and bond container and receiving equipment. The formation of vapours must be kept at a minimum and below current limit values (see above). Installation of a local exhaust system if normal air flow in the work room is not sufficient is recommended. Ensure eyewash and emergency showers are clearly marked. Ensure that eyewash stations and safety showers are located within easy reach. Apply standard precautions during use of the product. Avoid inhalation of vapours.

๐Ÿงค Hand Protection

Material: Butyl, Glove thickness: 0,3 mm, Breakthrough time: > 480 min., Standards: EN374-2, EN374-3, EN388

๐Ÿ‘๏ธ Eye Protection

Type: Face shield alternatively safety glasses with side shields. Standards: EN166

๐Ÿ˜ท Respiratory Protection

Type: Combination Filter A2B2E2K2, Class: Class 2 (medium capacity), Colour: Brown/Gray/Yellow/Green, Standards: EN14387

๐Ÿฆบ Skin/Body Protection

No special when used as intended

๐ŸŒ Environmental Exposure Controls

Keep damming materials near the workplace. If possible, collect spillage during work.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

3105

๐Ÿ“ฆ Proper Shipping Name

ORGANIC PEROXIDE TYPE D, LIQUID (Methyl ethyl ketone peroxide(s))

โš ๏ธ Transport Hazard Class

5.2

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for RESION MEKP Hardener?

The signal word for this substance is "danger".

What is the physical form of RESION MEKP Hardener?

RESION MEKP Hardener is a liquid with colourless color. It has characteristic odor.

What is RESION MEKP Hardener used for?

Curing agent for resins

What are the hazard statements for RESION MEKP Hardener?

This substance has 3 hazard statements: H242: Heating may cause a fire. H302: Harmful if swallowed. H314: Causes severe skin burns and eye damage.

What is the melting point of RESION MEKP Hardener?

The melting point is Testing not relevant or not possible due to the nature of the product. and the boiling point is Testing not relevant or not possible due to the nature of the product..