Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Tungstophosphoric acid hydrate for analysis EMSURE
- Product Code
- 100583
- Chemical Name
- Tungstophosphoric acid hydrate
Regulatory Identifiers
- CAS Number
- 12501-23-4 Check regulations →
- EC Number
- 603-020-3 Check regulations →
Identified Uses
Reagent for analysis
Manufacturers & Suppliers
Merckgroup
manufacturer
Merck Chemicals Ltd
regional supplier
Boulevard Industrial Park * Padge Road * Beeston * Nottingham * NG9 2JR
01159 430840
Emergency Contacts
Emergency Contact
+49 (0) 6151 722440
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS05
Hazard Statements
Precautionary Statements
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Phosphotungstic acid hydrate EC: 215-682-7 | 12501-23-4 | 100% | Yes |
The Safety Data Sheets for catalogue items are available at www.merck-chemicals.com
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air. Call in physician.
Symptoms: Cough, Shortness of breath
wash off with plenty of water. Remove contaminated clothing. Call a physician immediately.
Symptoms: Irritation and corrosion
rinse out with plenty of water. Immediately call in ophthalmologist.
Symptoms: Risk of blindness!
make victim drink water (two glasses at most), avoid vomiting (risk of perforation). Call a physician immediately. Do not attempt to neutralise.
Symptoms: Irritation and corrosion
Immediate Medical Attention
No information available.
Medical Treatment
No information available.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur
---
ortho-Phosphoric acid 85% for analysis EMSURE ACS,ISO,Reag. Ph Eur
---
Hydrofluoric acid 48% for analysis EMSURE® ACS,ISO,Reag. Ph Eur
---
Sulfuric acid 98% for analysis EMSURE
CAS: 7664-93-9
Sulfuric acid 25% for analysis EMSURE
---
Sodium acetate trihydrate for analysis EMSURE ACS,ISO,Reag. Ph Eur
CAS: 6131-90-4
Hydrochloric acid 25% for analysis EMSURE
---
Ammonium fluoride for analysis EMSURE ® ACS
CAS: 12125-01-8
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
For full contact: Glove material: Nitrile rubber, Glove thickness: 0.11 mm, Break through time: - 480 min. For splash contact: Glove material: Nitrile rubber, Glove thickness: 0.11 mm, Break through time: - 480 min. The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Tightly fitting safety goggles
Required when dusts are generated. Recommended Filter type: Filter P 2 (acc. to DIN 3181) for solid and liquid particles of harmful substances. The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Acid-resistant protective clothing
Do not empty into drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN 3260
- Shipping Name
- CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S. (TUNGSTOPHOSPHORIC ACID)
- Transport Class
- 8
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Tungstophosphoric acid hydrate for analysis EMSURE?
The signal word is danger.
What is the physical form of Tungstophosphoric acid hydrate for analysis EMSURE?
Tungstophosphoric acid hydrate for analysis EMSURE is a solid with light green color. It has odourless odor.
What is Tungstophosphoric acid hydrate for analysis EMSURE used for?
Reagent for analysis
What are the hazard statements for Tungstophosphoric acid hydrate for analysis EMSURE?
This substance has 1 hazard statement:
- H314: Causes severe skin burns and eye damage.
What is the melting point of Tungstophosphoric acid hydrate for analysis EMSURE?
The melting point is 107 C and the boiling point is not applicable.