Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Tris(hydroxymethyl)aminomethane GR for analysis buffer substance ACS,Reag. Ph Eur
- Product Code
- 108382
Regulatory Identifiers
- CAS Number
- 77-86-1 Check regulations →
- REACH No.
- 01-2119957659-16-XXXX
Identified Uses
Reagent for analysis For additional information on uses please refer to the Merck Chemicals portal (www.merckgroup.com).
Manufacturers & Suppliers
Merck Chemicals Ltd
distributor
Boulevard Industrial Park * Padge Road * Beeston * Nottingham * NG9 2JR
01159 430840
Emergency Contacts
Emergency Contact
+49 (0) 6151 722440
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| HNC(CHOH) CHNO (Hill) EC: 201-064-4 | --- | --- | No |
The Safety Data Sheets for catalogue items are available at www.merckgroup.com
First Aid Measures
Emergency procedures for chemical exposure incidents
fresh air.
Symptoms: Mucosal irritations, coughing, and dyspnoea after inhalation.
Take off immediately all contaminated clothing. Rinse skin with water/ shower.
Symptoms: irritations after contact with eyes and skin.
rinse out with plenty of water.
Symptoms: irritations after contact with eyes and skin.
make victim drink water (two glasses at most). Consult doctor if feeling unwell.
Symptoms: Nausea, Vomiting, Convulsions, Diarrhoea
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Titriplex® III GR for analysis (ethylenedinitrilotetraacetic acid, disodium salt dihydrate) ACS, ISO, Reag. Ph Eur
---
di-Ammonium hydrogen citrate for analysis EMSURE® ACS,Reag. Ph Eur
---
Chromotropic acid disodium salt dihydrate for analysis ACS, Reag. Ph Eur
CAS: 5808-22-0
Sodium acetate trihydrate for analysis EMSURE® ACS,ISO,Reag. Ph Eur
CAS: 6131-90-4
Titriplex® II for analysis (ethylenedinitrilotetraacetic acid) ACS, Reag. Ph Eur
CAS: 60-00-4
Methenamine GR for analysis Reag. Ph Eur
---
Glyoxalbis(2-hydroxyanil) GR for analysis Reag. Ph Eur
CAS: 1149-16-2
HEXAMETHYLENETETRAMINE, REAGENT, ACS
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Technical measures and appropriate working operations should be given priority over the use of personal protective equipment. See section 7.1.
full contact: Glove material: Nitrile rubber Glove thickness: 0.11 mm Break through time: - 480 min splash contact: Glove material: Nitrile rubber Glove thickness: 0.11 mm Break through time: - 480 min The protective gloves to be used must comply with the specifications of EC Directive 89/686/EEC and the related standard EN374, for example KCL 741 Dermatril L (full contact), KCL 741 Dermatril L (splash contact). The breakthrough times stated above were determined by KCL in laboratory tests acc. to EN374 with samples of the recommended glove types. This recommendation applies only to the product stated in the safety data sheet, supplied by us and for the designated use. When dissolving in or mixing with other substances and under conditions deviating from those stated in EN374 please contact the supplier of CE-approved gloves (e.g. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).
Safety glasses
required when dusts are generated. Recommended Filter type: Filter P 1 (acc. to DIN 3181) for solid particles of inert substances The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
Protective clothing needs to be selected specifically for the workplace, depending on concentrations and quantities of the hazardous substances handled. The chemical resistance of the protective equipment should be enquired at the respective supplier.
Do not let product enter drains.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Tris(hydroxymethyl)aminomethane GR for analysis buffer substance ACS,Reag. Ph Eur?
The signal word is no signal word.
What is the physical form of Tris(hydroxymethyl)aminomethane GR for analysis buffer substance ACS,Reag. Ph Eur?
Tris(hydroxymethyl)aminomethane GR for analysis buffer substance ACS,Reag. Ph Eur is a solid with white color. It has odourless odor.
What is Tris(hydroxymethyl)aminomethane GR for analysis buffer substance ACS,Reag. Ph Eur used for?
Reagent for analysis For additional information on uses please refer to the Merck Chemicals portal (www.merckgroup.com).
What is the melting point of Tris(hydroxymethyl)aminomethane GR for analysis buffer substance ACS,Reag. Ph Eur?
The melting point is 168 - 172 C and the boiling point is 219 - 220 C at 13.3 hPa.