NextSDS Logo
Ka

Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600

NO SIGNAL WORD Solid SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600
Product Form
Substance

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial use Manufacture of plastic materials

Overview

Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600 is a powder. substance commonly used industrial use manufacture of plastic materials.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P501: Dispose of contents and container to an approved waste disposal plant.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Kaneka Belgium NV

undefined

Nijverheidsstraat 16 2260 Westerlo-Oevel - Belgium

BE

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32-14-25 78 00

BE

24 hours per day, 7 days per week.

Emergency Contact

+32-14-25 78 10

BE

24 hours per day, 7 days per week.

National Poisons Information Centre Beaumont Hospital

+353 1 809 2566

IE

Healthcare professionals- 24/7

National Poisons Information Centre Beaumont Hospital

+353 1 809 2166

IE

public, 8am - 10pm, 7/7

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Substance name : Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Acrylic polymer N/A 96% Non-hazardous
Sulfuric acid, mono-C12-14-alkyl esters, sodium salts
EC: 287-809-4
85586-07-8 0.5-4% Hazardous
ethylenebis(oxyethylene) bis[3-(5-tert-butyl-4-hydroxy-m-tolyl)propionate]
EC: 253-039-2
36443-68-2 0.025-0.25% Hazardous

Composition Notes

Full text of H- and EUH-statements: see section 16

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Remove person to fresh air. If signs/symptoms continue, get medical attention.

Symptoms:

May cause nose, throat, and lung irritation. (dust).

Skin Contact

After contact with skin, wash immediately with plenty of water and soap. In case of doubt or persistent symptoms, consult always a physician.

Symptoms:

Contact with dust may cause mechanical irritation or drying of the skin.

Eye Contact

Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. In case of doubt or persistent symptoms, consult always a physician.

Symptoms:

Dust may cause painful eye irritation and tearing.

Ingestion/Swallowing

Get immediate medical advice/attention. Rinse mouth. Induce vomiting if person is conscious. Never give anything by mouth to an unconscious person.

Symptoms:

This product has no known adverse effect on human health. Non-hazardous substance .

Immediate Medical Attention Required

Get immediate medical advice/attention. Treat symptomatically.

Medical Treatment

Treat symptomatically.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Molecular Weight
Not available
Lower Explosive Limit
Not available
Solubility
miscible with most organic solvents.
Solubility In Fat
Not available
Solubility In Water
Not available
Odor Threshold
No data available
Auto Ignition Temperature
> 370 °C
Bulk Density
+/- 500 g/l
Solidification Point
Not available
Relative Density
+/- 1
Boiling Point
Decomposes below the boiling point.
Critical Property
Explosive Limits
Not available
Flammability
Not fulfilling criteria for hazard class "Flammable Solids".
Freezing Point
No data available
Metal Corrosion
Not available
Evaporation Rate
No data available
Flash Point
No data available
Critical Property
Upper Explosive Limit
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
No data available
Form
Not available
Softening Point
Not available
Partition Coefficient
Not applicable
Vapor Pressure
Negligible
Cloud Point
Not available
Properties Status
Not available
Vapor Density
Negligible
Density
Not available
Ph
No data available
Colour Intensity
Not available
Decomposition Temperature
200 °C
State Under Standard Conditions
Not available
Colour
White.
Physical State Data
solid
Physical State
Solid
Critical Property
Appearance
Powder.
Voc Content
Not available
Melting Point
No data available
Critical Property
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Odor
Slight. acrylic-like.
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Use only in area provided with appropriate exhaust ventilation. Apply measures to prevent dust explosions. Provide adequate precautions, such as electrical grounding and bonding, or inert atmospheres. Organisational measures to prevent/limit releases, dispersion and exposure. See also section 7 .

Hand Protection

The selection of specific gloves for a specific application and time of use in a working area, should also take into account other factors on the working space, such as (but not limited to): other chemicals that are possibly used, physical requirements (protection against cutting/drilling, skill, thermal protection), and the instructions/specification of the supplier of gloves. (EN388). Impervious gloves : . All types

Eye Protection

Safety glasses with side-shields (EN166)

Respiratory Protection

In case of insufficient ventilation, wear suitable respiratory equipment. Effective dust mask (EN149). Filter type: type P1

Skin/Body Protection

Wear suitable protective clothing. Overall. Chemical resistant safety shoes .

Environmental Exposure Controls

Avoid release to the environment. Comply with applicable Community environmental protection legislation.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600?

The signal word for this substance is "no signal word".

What is the physical form of Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600?

Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600 is a solid appearing as powder. with white. color. It has slight. acrylic-like. odor.

What is the solubility of Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600?

miscible with most organic solvents.

What is Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600 used for?

Industrial use Manufacture of plastic materials

What are the hazard statements for Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600?

This substance has 1 hazard statements: H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Kane Ace™ FM22, FM50, FM56, FM57, UF100, UF600?

The melting point is No data available and the boiling point is Decomposes below the boiling point..