NextSDS Logo
Safety Data Sheet EN

Synfluid® mPAO 100 cSt

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Synfluid® mPAO 100 cSt
Product Code
1116564, 1106295, 1106303

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricant

Manufacturers & Suppliers

C

Chevron Phillips Chemical Company LP

manufacturer

10001 Six Pines Drive, The Woodlands, TX 77380

C

Chevron Phillips Chemicals International N.V.

local supplier

Airport Plaza (Stockholm Building), Leonardo Da Vincilaan 19, 1831 Diegem, Belgium

Emergency Contacts

Emergency Contact

866.442.9628

Emergency Contact

1.832.813.4984

CHEMTREC

800.424.9300

CHEMTREC

703.527.3887

CHEMWATCH

+612 9186 1132

Emergency Contact

0532 8388 9090

Mexico CHEMTREC

01-800-681-9531

SOS-Cotec

0800.111.767

SOS-Cotec

+55.19.3467.1600

Emergency Contact

+(54)-1159839431

BIG

+32.14.584545

VIZ

+43 1 406 43 43

Emergency Contact

070 245 245

Emergency Contact

+359 2 9154 233

Emergency Contact

+3851 2348 342

Emergency Contact

1401

Toxicological Information Center

+420 224 919 293

Toxicological Information Center

+420 224 915 402

Danish Poison Center (Giftlinjen)

+45 8212 1212

BIG

+32.14.584545

Emergency Contact

0800 147 111

Emergency Contact

09 471 977

ORFILA number (INRS)

+33 (0) 1 45 42 59 59

BIG

+32.14.584545

Emergency Contact

(0030) 2107793777

Emergency Contact

+36-80-201-199

Emergency Contact

543 2222

BIG

+32.14.584545

POISON CENTER MILAN

+39 02 66101029

POISON CENTER ROME

+39 06 3054343

POISON CENTER ROME

+39 06 68593726

POISON CENTER ROME

+39 06 4997 8000

POISON CENTER FOGGIA

+39 0881 732326

POISON CENTER NAPLES

+39 081 7472870

POISON CENTER FLORENCE

+39 055 7947819

POISON CENTER PAVIA

+39 0382 24444

POISON CENTER BERGAMO

800 883 300

POISON CENTER VERONA

800 011 858

State Fire and Rescue Service

112

Toxicology and Sepsis Clinic Poisoning and Drug Information Center

+371 67042473

BIG

+32.14.584545

Emergency Contact

+370 (85) 2362052

Emergency Contact

(+352) 8002 5500

Emergency Contact

+356 2395 2000

NVIC

+31 (0)88 755 8000

Emergency Contact

22 59 13 00

BIG

+32.14.584545

CIAV

+351 800 250 250

Emergency Contact

+40213183606

Emergency Contact

+421 2 5477 4166

Emergency Contact

112

National Emergency Telephone Number of Spanish Poison Centre

+34 91 562 04 20

Emergency Contact

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type substance

Synonyms : Polyalphaolefin; PAO Molecular formula : Polymer

Chemical Name CAS Number Concentration Hazardous
1-Octene Homopolymer, Hydrogenated 70693-43-5 100% No

Notes

Contains no hazardous ingredients according to GHS.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

If unconscious, place in recovery position and seek medical advice. If symptoms persist, call a physician.

Skin contact

Wash off with soap and water. Wash contaminated clothing before re-use.

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. Keep eye wide open while rinsing. If eye irritation persists, consult a specialist.

Symptoms: eye irritation

Ingestion

Keep respiratory tract clear. Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

Immediate Medical Attention

If symptoms persist, call a physician.

Medical Treatment

No information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

Unsuitable media

High volume water jet.

Specific hazards

Exposure to decomposition products may be a hazard to health.

Instructions

Standard procedure for chemical fires.

Firefighter Protection

Wear self-contained breathing apparatus for firefighting if necessary.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Material can create slippery conditions.

Environmental

Clean contaminated floors and objects thoroughly while observing environmental regulations.

Cleanup methods

Wipe up with absorbent material (e.g. cloth, fleece). Keep in suitable, closed containers for disposal.

Materials: cloth, fleece

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. Dispose of rinse water in accordance with local and national regulations.

Storage

Keep container tightly closed in a dry and well-ventilated place. Electrical installations / working materials must comply with the technological safety standards.

Hygiene

Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Normal measures for preventive fire protection.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Adequate ventilation to control airborne concentrations below the exposure guidelines/limits. Consider the potential hazards of this material (see Section 2), applicable exposure limits, job activities, and other substances in the work place when designing engineering controls and selecting personal protective equipment.

Hands

The suitability for a specific workplace should be discussed with the producers of the protective gloves. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion, and the contact time. Gloves should be discarded and replaced if there is any indication of degradation or chemical breakthrough.

Eyes

Eye wash bottle with pure water. Tightly fitting safety goggles.

Respiratory

If ventilation or other engineering controls are not adequate to maintain minimal oxygen content of 19.5% by volume under normal atmospheric pressure, a supplied-air NIOSH approved respirator may be appropriate.

Skin/Body

Choose body protection according to the amount and concentration of the substance and the task performed at the work place. Appropriate PPE may include: Lightweight protective clothing.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
clear, light
Colour Intensity
---
Form
Oil
Odor
---
Odor Threshold
---
Ph
No data available
Melting Point
---
Boiling Point
>250°C (>482°F)
Flash Point
255°C (491°F)
Freezing Point
-44°C (-47°F)
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
---
Vapor Pressure
---
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0,84 g/cm3
Flammability
---
Upper Explosive Limit
No data available
Lower Explosive Limit
No data available
Explosive Limits
---
Auto Ignition Temperature
310°C (590°F)
Decomposition Temperature
No data available
Solubility
Soluble in hydrocarbon solvents; insoluble in water.
Partition Coefficient
---
Solubility In Water
insoluble in water.
Solubility In Fat
---
Molecular Weight
Varies
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
1014 cSt at 40°C (104°F)
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

This material is considered stable under normal ambient and anticipated storage and handling conditions of temperature and pressure.

Reactivity

Stable at normal ambient temperature and pressure.

Hazardous reactions

No decomposition if stored and applied as directed.

Avoid

No data available.

Incompatible

No data available.

Decomposition

No data available.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Ecotoxicity effects Toxicity to fish : This material is not expected to be harmful to aquatic organisms. Information given is based on data obtained from similar substances. Toxicity to daphnia and other aquatic invertebrates : This material is not expected to be harmful to aquatic organisms. Information given is based on data obtained from similar substances. Toxicity to algae : This material is not expected to be harmful to aquatic organisms. Information given is based on data obtained from similar substances.

The material is not expected to be harmful to aquatic organisms based on data from similar substances.

12.2 Persistence and degradability

Biodegradability : This material is not expected to be readily biodegradable.

The material is not expected to be readily biodegradable.

12.3 Bioaccumulative potential

Elimination information (persistence and degradability)

12.4 Mobility in soil

Mobility : No data available

Results of PBT and vPvB assessment

Results of PBT assessment : This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

The substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.

Endocrine disrupting properties

Endocrine disrupting properties : The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher.

The substance/mixture does not contain components considered to have endocrine disrupting properties at levels of 0.1% or higher.

Other adverse effects

Additional ecological information : No data available
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Use material for its intended purpose or recycle if possible.

Disposal

Do not dispose of waste into sewer. Do not contaminate ponds, waterways or ditches with chemical or used container. Send to a licensed waste management company.

Waste Codes

40 CFR 261 RCRA
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Commission Regulation (EU) 2020/878 of 18 June 2020 amending Regulation (EC) No 1907/2006 of the European Parliament and of the Council on the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH)

Chemical Safety Assessment Not performed
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Synfluid® mPAO 100 cSt?

The signal word is no signal word.

What is the physical form of Synfluid® mPAO 100 cSt?

Synfluid® mPAO 100 cSt is a liquid with clear, light color.

What is the solubility of Synfluid® mPAO 100 cSt?

Soluble in hydrocarbon solvents; insoluble in water.

What is Synfluid® mPAO 100 cSt used for?

Lubricant