Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- PALMERA A1601
- Chemical Name
- Palmitic Acid
Regulatory Identifiers
- CAS Number
- 57-10-3 Check regulations →
- EC Number
- 200-312-9 Check regulations →
- REACH No.
- 01-2119538235-41-0000
Identified Uses
Additive, Tanning agents, Lubricant, Intermediate, Laboratory chemicals, Skin cosmetics, Cosmetic auxiliary
Manufacturers & Suppliers
KLK Emmerich GmbH
manufacturer
Steintor 9, 46446 Emmerich am Rhein GERMANY
+49 (0) 2822 72 0
KLK Emmerich GmbH
manufacturer
Henkelstr. 67 D-40589 Düesseldorf
+49 (0)2822 720
Emergency Contacts
Emergency Contact
+44 20 3885 0382
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
Manage your Safety Data Sheets
Organize and access chemical safety data with ease
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Palmitic Acid EC: 200-312-9 | 57-10-3 | --- | No |
Notes
The product is not classified as hazardous to health or environment, according to the CLP regulation.
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly.
Symptoms: skin irritation
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Do not induce vomiting; call for medical help immediately. Rinse out mouth and then drink plenty of water.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Sand CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam. Use fire extinguishing methods suitable to surrounding conditions.
Water with full jet
No further relevant information available.
Avoid breathing dust/fume/gas/mist/vapours/spray.
Firefighter Protection
In case of insufficient ventilation, wear suitable respiratory equipment.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Use respiratory protective device against the effects of fumes/dust/aerosol. Wear protective equipment. Keep unprotected persons away.
Do not allow product to reach sewage system or any water course.
Dispose of the material collected according to regulations.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and direct sunlight. Keep respiratory protective device available.
Store only in the original receptacle. Store away from oxidising agents. Keep container tightly sealed. Protect from heat and direct sunlight.
Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.
Safety glasses
Suitable respiratory protective device recommended.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable at environment temperature. No decomposition if used according to specifications.
No further relevant information available.
Risk of dust explosion if enriched with fine dust in the presence of air.
See Section 7 for information on safe handling.
See Section 7 for information on safe handling.
Irritant gases/vapours, Carbon monoxide and carbon dioxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- Not regulated
- Shipping Name
- Not regulated
- Transport Class
- Not regulated
- Packing Group
- Not regulated
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for PALMERA A1601?
The signal word is no signal word.
What is PALMERA A1601 used for?
Additive, Tanning agents, Lubricant, Intermediate, Laboratory chemicals, Skin cosmetics, Cosmetic auxiliary
What is the melting point of PALMERA A1601?
The melting point is ca. 62.5 °C and the boiling point is ca. 351 °C.