Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- ZEP 40 NEW
- Product Code
- 97770001
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- KH2N-Q49N-Y405-E42V
Identified Uses
Window cleaner. Sector of Use: SU3 Industrial uses, SU22 Professional uses. Product category: PC35 Washing and cleaning products. Process category: PROC7 Industrial spraying, PROC11 Non industrial spraying. Environmental release category: ERC8a, ERC8d.
Uses advised against
No further relevant information available.
Manufacturers & Suppliers
ZEP ITALIA SRL
manufacturer
Piazzale Luigi Cadorna, 2, 20123 Milano (MI) - Italy; Via Nettunense Km. 25.000, 04011 Aprilia (LT) - Italy
+39.06.926691
http://www.zep.it
ZEP Industries BV
manufacturer
Vierlinghweg 30, 4612 PN Bergen op Zoom, The Netherlands
+31 164 250 100
ZEP UK Ltd
distributor
Tanhouse Lane, Widnes Cheshire, WA8 0RD, United Kingdom
+44 (0)151 422 1000
http://www.zep.co.uk
Emergency Contacts
NHS
+44 0845 46 47
NHS
+44 08454 24 24 24
emergency number (europe)
112
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ammonia EC: 215-647-6 | 1336-21-6 | 0.1 - 0.25% | Yes |
| ethanol EC: 200-578-6 | 64-17-5 | 10 - 25% | Yes |
| Hydrocarbons, C4 Petroleum gas EC: 289-339-5 | 87741-01-3 | 2.5 - 5% | Yes |
| 1-butoxypropan-2-ol EC: 225-878-4 | 5131-66-8 | 2.5 - 5% | Yes |
| propane EC: 200-827-9 | 74-98-6 | 1 - 2.5% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Supply fresh air; consult doctor in case of complaints.
Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.
Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.
Seek immediate medical advice.
Immediate Medical Attention
Seek immediate medical advice.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.
During heating or in case of fire poisonous gases are produced.
Firefighter Protection
Do not inhale explosion gases or combustion gases. Wear fully protective suit. Wear self-contained respiratory protective device.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Wear protective equipment. Keep unprotected persons away.
Do not allow to enter sewers/ surface or ground water.
Related Products
Similar products with comparable safety profiles
ZEP 2000 NEW
UFI: 4TW1-N0VG-EV3K-SHE8
ZEP 45 AERO
UFI: 7J6T-1KST-RT8J-F7MX
ZEP SPRAY MOP REFILL & FLOOR CLEANER_1GL_4CT
---
ZEP FAST 505 DEGREASER & CLEANER_1GL_4CT
---
ZEP CONCENTRATED GLASS CLEANER 5GL
---
JEFFCAT® ZR 40
CAS: 3855-32-1
ZEP FOAMING WALL CLEANER 20N18_12CT
---
ZEP FOAMING COIL CLEANER 20N18 12CT
---
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Keep away from heat and direct sunlight. Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke. Pressurised container: protect from sunlight and do not expose to temperatures exceeding 50°C, i.e. electric lights. Do not pierce or burn, even after use.
Keep receptacle tightly sealed. Protect from heat and direct sunlight. Mechanical ventilation is not required for storage. Observe official regulations on storing packagings with pressurised containers.
Do not spray onto a naked flame or any incandescent material. Keep ignition sources away - Do not smoke.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No further data; see section 7.
Material of gloves: The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material cannot be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed. The determined penetration times according to EN 16523-1:2015 are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended. Not suitable are gloves made of the following materials: Strong material gloves
Not required.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
No decomposition if used according to specifications.
No further relevant information available.
No dangerous reactions known.
No further relevant information available.
Store away from flammable substances.
No dangerous decomposition products known.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1950
- Shipping Name
- AEROSOLS
- Transport Class
- 2.1
- Packing Group
- Void
Segregation groups (SGG18) Alkalis
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for ZEP 40 NEW?
The signal word is danger.
What is the physical form of ZEP 40 NEW?
ZEP 40 NEW is a aerosol with white color. It has characteristic odor.
What is ZEP 40 NEW used for?
Window cleaner. Sector of Use: SU3 Industrial uses, SU22 Professional uses. Product category: PC35 Washing and cleaning products. Process category: PROC7 Industrial spraying, PROC11 Non industrial spraying. Environmental release category: ERC8a, ERC8d.
What are the hazard statements for ZEP 40 NEW?
This substance has 1 hazard statement:
- H222: Extremely flammable aerosol. Pressurised container: May burst if heated.