Product Information

Product Name
Rustlick™ Sump-Side Defoamer
Product Code
78640

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Tank side additive for foam control

Uses advised against

None known.

Manufacturers & Suppliers

ITW Pro Brands logo

ITW Pro Brands

manufacturer

4647 Hugh Howell Rd Tucker, GA 30084 United States

1-800-241-8334 / 770-243-8800

http://www.lpslabs.com

Emergency Contacts

Chemtrec

1-800-424-9300

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified
Not Classified
Not Classified
Not Classified

GHS Pictograms

Hazard Statements

The mixture does not meet the criteria for classification.

Precautionary Statements

P234 Store away from incompatible materials.
P264 Wash hands after handling.
P501 Dispose of waste and residues in accordance with local authority requirements.
Observe good industrial hygiene practices.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The manufacturer lists no ingredients as hazardous to health according to OSHA 29 CFR 1910.1200.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. Call a physician if symptoms develop or persist.

Skin contact

Wash off with soap and water. Get medical attention if irritation develops and persists.

Eye contact

Rinse with water. Get medical attention if irritation develops and persists.

Symptoms: Direct contact with eyes may cause temporary irritation.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Immediate Medical Attention

Get medical attention if symptoms occur/develop/persist.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2).

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

During fire, gases hazardous to health may be formed.

Instructions

Move containers from fire area if you can do so without risk. Use standard firefighting procedures and consider the hazards of other involved materials.

Firefighter Protection

Self-contained breathing apparatus and full protective clothing must be worn in case of fire.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Keep unnecessary personnel away.

Small spill

Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.

Large spill

Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water.

Environmental

Avoid discharge into drains, water courses or onto the ground.

Cleanup methods

Absorb in vermiculite, dry sand or earth and place into containers. Following product recovery, flush area with water. Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination.

Materials: vermiculite, dry sand, earth, absorbent material (e.g. cloth, fleece)

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Do not get in eyes, on skin, or on clothing. Avoid prolonged exposure.

Storage

Store in tightly closed container.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Good general ventilation should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Wear suitable protective clothing.

Eyes

Wear safety glasses with side shields (or goggles).

Respiratory

In case of insufficient ventilation, wear suitable respiratory equipment.

Skin/Body

Wear appropriate chemical resistant gloves.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid.
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Opaque. White.
Colour
Opaque. White.
Colour Intensity
---
Form
Liquid.
Odor
Mild.
Odor Threshold
Not available.
Ph
8.5
Melting Point
Not available.
Boiling Point
>212 °F (>100 °C)
Flash Point
>399.2 °F (>204.0 °C) Cleveland Open Cup
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not available.
Vapor Pressure
< 1 mm Hg
Vapor Density
>1
Relative Density
1.05
Bulk Density
---
Density
---
Flammability
Not applicable.
Upper Explosive Limit
Not available.
Lower Explosive Limit
Not available.
Explosive Limits
---
Auto Ignition Temperature
Not available.
Decomposition Temperature
Not available.
Solubility
---
Partition Coefficient
Not available.
Solubility In Water
Dispersable
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

The product is stable and non-reactive under normal conditions of use, storage and transport.

Hazardous reactions

No dangerous reaction known under conditions of normal use.

Avoid

Avoid temperatures exceeding the decomposition temperature. Contact with incompatible materials.

Incompatible

Strong oxidizing agents.

Decomposition

Carbon oxides.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Rustlick™ Sump-Side Defoamer?

The signal word is no signal word.

What is the physical form of Rustlick™ Sump-Side Defoamer?

Rustlick™ Sump-Side Defoamer is a liquid. appearing as opaque. white. with opaque. white. color. It has mild. odor.

What is Rustlick™ Sump-Side Defoamer used for?

Tank side additive for foam control

What are the hazard statements for Rustlick™ Sump-Side Defoamer?

This substance has 1 hazard statement:

  • The mixture does not meet the criteria for classification.

What is the melting point of Rustlick™ Sump-Side Defoamer?

The melting point is Not available. and the boiling point is >212 °F (>100 °C).