NextSDS Logo
Safety Data Sheet EN

AGITAN® 295

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
AGITAN® 295

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Defoamers, Anti-foaming agent

Manufacturers & Suppliers

M

MÜNZING CHEMIE GmbH

manufacturer

Münzingstrasse 2 74232 Abstatt, Germany

+49 7131 987-100

Emergency Contacts

CHEMTREC

+1 703 741 5970

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

hydrocarbons, fatty derivates, hydrophobic silica, emulsifiers

Chemical Name CAS Number Concentration Hazardous
Distillates(petroleum), hydrotreated heavy naphthenic EC: 265-155-0 64742-52-5 20 - 50% Yes
Distillates(petroleum), hydrotreated light naphthenic EC: 265-156-6 64742-53-6 10 - 20% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Skin contact

Immediately wash with water and soap and rinse thoroughly.

Eye contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

Ingestion

Do not induce vomiting; call for medical help immediately.

Immediate Medical Attention

call for medical help immediately

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Unsuitable media

Water with full jet

Specific hazards

In case of fire, the following can be released: Carbon monoxide (CO)

Firefighter Protection

Do not inhale explosion gases or combustion gases.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Wear protective clothing. Particular danger of slipping on leaked/spilled product.

Environmental

Do not allow to enter sewers/ surface or ground water.

Cleanup methods

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Materials: sand, diatomite, acid binders, universal binders, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from heat and direct sunlight. Prevent formation of aerosols.

Storage

Store in a cool location. Store in cool, dry conditions in well sealed receptacles.

Fire prevention

Protect from heat. Keep ignition sources away - Do not smoke.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see section 7.

Hands

Only use chemical-protective gloves with CE-labelling of category III. The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation. Material of gloves: Nitrile rubber, NBR. Recommended thickness of the material: 0,4 mm. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: For the mixture of chemicals mentioned below the penetration time has to be at least 480 minutes (Permeation according to EN 16523-1:2015: Level 6). The determined penetration times according to EN 16523-1:2015 are not performed under practical conditions. Therefore a maximum wearing time, which corresponds to 50% of the penetration time, is recommended. The exact break through time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Goggles recommended during refilling

Respiratory

Use suitable respiratory protective device only when aerosol or mist is formed.

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Upper Explosive Limit
≈ 10 Vol % (01-2119467170-45)
Colour
Light brown
Solidification Point
---
Softening Point
---
State Under Standard Conditions
---
Colour Intensity
---
Partition Coefficient
Not applicable (mixture).
Bulk Density
---
Dynamic Viscosity
225 mPas (DIN EN ISO 3219)
Metal Corrosion
---
Crystallisation Point
---
Boiling Point
The value is above the measuring range of the method. Up to 250 °C no boiling point was observed.
Kinematic Viscosity
22 mm²/s (DIN EN ISO 51562)
Odor Threshold
Not available
Lower Explosive Limit
≈ 1 Vol % (01-2119467170-45)
Form
---
Vapor Pressure
<0,1 hPa (01-2119467170-45)
Vapor Density
Not applicable (mixture).
Physical State Data
liquid
Ph
Mixture is non-polar/aprotic.
Physical State
Liquid
Molecular Weight
---
Decomposition Temperature
Not applicable
Odor
Mineral-oil-like
Solubility In Water
Emulsifiable.
Voc Content
---
Freezing Point
---
Properties Status
---
Solubility
---
Appearance
---
Solubility In Fat
---
Flash Point
>140 °C (DIN EN ISO 2719)
Density
0,95 g/cm³ (DIN EN ISO 2811-1)
Relative Density
---
Explosive Limits
---
Relative Evaporation Rate
---
Flammability
The mixture is capable of catching fire or being set on fire.
Cloud Point
---
Melting Point
It is technically not possible to determine a value.
Auto Ignition Temperature
Not available for the mixture or its ingredients.
Evaporation Rate
Not determined.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Reactivity

No further relevant information available.

Hazardous reactions

No dangerous reactions known.

Avoid

No further relevant information available.

Incompatible

No further relevant information available.

Decomposition

No dangerous decomposition products known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for AGITAN® 295?

The signal word is no signal word.

What is the physical form of AGITAN® 295?

AGITAN® 295 is a liquid with light brown color. It has mineral-oil-like odor.

What is AGITAN® 295 used for?

Defoamers, Anti-foaming agent

What is the melting point of AGITAN® 295?

The melting point is It is technically not possible to determine a value. and the boiling point is The value is above the measuring range of the method. Up to 250 °C no boiling point was observed..