NextSDS Logo
Au

Automat XR Fixer concentrate

NO SIGNAL WORD liquid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Automat XR Fixer concentrate

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Special X-ray set for Drr developers. Product categories [PC]: PC30 - Photo-chemicals
Uses Advised Against
None, if handled according to order.

Overview

Automat XR Fixer concentrate is a liquid substance commonly used special x-ray set for drr developers. product categories [pc]: pc30 - photo-chemicals.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P280: Wear protective gloves and eye/face protection.
  • P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
  • P353: Rinse skin with water/shower.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

orochemie GmbH + Co. KG

manufacturer

๐Ÿ“

Max-Planck-Strae 27, 70806 Kornwestheim

๐ŸŒ

DE

๐Ÿ“ž

+49 7154 1308-0

๐Ÿ“ 

+49 7154 1308-40

DRR DENTAL AG

distributor

๐Ÿ“

Hpfigheimer Strae 17, 74321 Bietigheim-Bissingen, Germany

๐ŸŒ

DE

๐Ÿ“ž

+49 7142 705-0

๐Ÿ“ 

+49 7142 705-500

DRR DENTAL [Products] UK Ltd.

distributor

๐Ÿ“

14 Linnell Way - Telford Way Industrial Estate, Kettering Northants NN16 8PS, United Kingdom

๐ŸŒ

GB

๐Ÿ“ž

+44 1536 526740

๐Ÿ“ 

+44 1536 526749

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

+49 6132 84463

๐ŸŒ

DE

๐Ÿ•’

24 h/7 d

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Drr Automat XR Fixer concentrate contains ammonium thiosulfate, organic acids and auxiliary agents in aqueous solution.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
ACETIC ACID
EC: 200-580-7
64-19-7 5-8% โš ๏ธ Hazardous
SODIUM SULPHITE
EC: 231-821-4
7757-83-7 1-4% โš ๏ธ Hazardous
BORIC ACID
EC: 233-139-2
10043-35-3 1-2% โš ๏ธ Hazardous

Additional Information

Full text of R-, H- and EUH-phrases: see section 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Provide fresh air. In case of respiratory tract irritation, consult a physician.

๐Ÿ–๏ธ Skin Contact

Wash with plenty of water. When in doubt or if symptoms are observed, get medical advice.

๐Ÿ‘๏ธ Eye Contact

In case of contact with eyes flush immediately with plenty of flowing water for 10 to 15 minutes holding eyelids apart and consult an ophthalmologist.

๐Ÿฝ๏ธ Ingestion/Swallowing

If swallowed, immediately drink: Water Never give anything by mouth to an unconscious person or a person with cramps. Do not induce vomiting. Call a physician immediately.

๐Ÿšจ Immediate Medical Attention Required

Call a physician immediately (after ingestion).

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
liquid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
liquid
๐ŸŽจ Colour
colourless
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
Acetic acid
๐Ÿ“Š Odor Threshold
No data available
๐Ÿงช Ph
4 - 5
๐ŸงŠ Melting Point
( 1013 hPa ) No data available
Critical Property
๐Ÿ’จ Boiling Point
( 1013 hPa ) ca. 100 C
Critical Property
๐Ÿ”ฅ Flash Point
not applicable
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not available
๐Ÿ’จ Vapor Pressure
Not available
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
( 20 C ) 1,1 - 1,3 g/cm [3]
Critical Property
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
not applicable
๐Ÿ“Š Lower Explosive Limit
not applicable
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
not applicable
๐Ÿ“Š Decomposition Temperature
( 1013 hPa ) No data available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
No data available
๐Ÿ“Š Solubility In Water
( 20 C ) 100 Wt %
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not corrosive to metals.
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Provide adequate ventilation.

๐Ÿงค Hand Protection

Short-term exposure (Level 2: < 30 min): disposable gloves to EN374 category III, e.g., nitrile rubber, material thickness 0.1 mm. Long-term exposure (Level 6: < 480 min): protective gloves to EN374 category III, e.g., nitrile rubber, material thickness 0.7 mm. When handling with chemical substances, protective gloves must be worn with the CE-label including the four control digits.

๐Ÿ‘๏ธ Eye Protection

Eye glasses with side protection DIN EN 166

๐Ÿ˜ท Respiratory Protection

Usually no personal respirative protection necessary.

๐Ÿฆบ Skin/Body Protection

Body protection: not applicable.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Automat XR Fixer concentrate?

The signal word for this substance is "no signal word".

What is the physical form of Automat XR Fixer concentrate?

Automat XR Fixer concentrate is a liquid appearing as liquid with colourless color. It has acetic acid odor.

What is Automat XR Fixer concentrate used for?

Special X-ray set for Drr developers. Product categories [PC]: PC30 - Photo-chemicals

What is the melting point of Automat XR Fixer concentrate?

The melting point is ( 1013 hPa ) No data available and the boiling point is ( 1013 hPa ) ca. 100 C.