NextSDS Logo
Safety Data Sheet EN

Tandemol H 674 I-LV

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Tandemol H 674 I-LV
Product Code
60046741-M

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Rolling Additive

Uses advised against

Any other purpose.

Manufacturers & Suppliers

H

Houghton plc

manufacturer

Beacon Road, Trafford Park, Manchester, M17 1AF

+44 (0)161 874 5000

H

Houghton S.A.S.

manufacturer

604 Bd Albert Camus, BP 60041, 69652 Villefranche sur saone, France

(0) 4 74 65 65 00

H

Houghton Iberica S.A.

manufacturer

Pol. Ind. Can Salvatella-TorreMateu, 08210 Barbera del Valles, Barcelona, SPAIN

+(34 93) 718 85 00

H

Houghton Deutschland GmbH

manufacturer

Giselherstr. 57. D-44319. Dortmund, Deutschland

+49 (0) 231/9277-0

H

Houghton Italia S.p.A.

manufacturer

Via Postiglione, 30, 10024 Moncalieri (TO), ITALY

(+39) 011 6475811

H

Houghton Benelux B.V.

manufacturer

Hoogoorddreef 15, Unit 3, 1101BA Amsterdam, Holland

00800 1624 5840

H

Houghton Sverige AB

manufacturer

La Cours Gata 4, 252 31 Helsingborg, Sverige

+46 42 29 55 10

H

Houghton Polska SP z.o.o

manufacturer

UlKapelanka 17, 30-347 Krakow, Poland

+48 122665240

H

Houghton Ukraine Ltd

manufacturer

13, Prirechnaya St., Kiev 04213, Ukraine

+38 (044) 360-10-24

H

Houghton Danmark A/S

manufacturer

Energivej 3, DK-4180 Sorø, Danmark

+45 45 85 23 00

H

Houghton Magyarország Kft.

manufacturer

Noszlopy utca 2., 1103 Budapest, Hungary

+36 28 999 430

H

Houghton Kimya San. A.§

manufacturer

Kosuyolu Mah, Asma Dall Sok, No: 1434718 Kadıköy, Istanbul, Türkiye

+90 216 325 15 15

H

Houghton CZ s.r.o.

manufacturer

Bartošova 3, 602 00 Brno, Czech Republic

+420 542 213 332

Emergency Contacts

Carechem 24 International

+44 1235 239670

Notfall-Telefonnummer

+43 (0) 1 406 4343

Emergency Contact

+32 (0)70 245 245

Emergency Contact

+359 2 9154 409

Emergency Contact

+385 1 2348 342

Carechem 24 International

+420 228 882 830

Telefonní číslo pro naléhavé situace

+420 224 919 293

Carechem 24 International

+45 8988 2286

Giftlinjen

+45 82 12 12 12

Műrgistusteabekeskuse

+372 626 93 90

Carechem 24 International

+358 9 7479 0199

Hätäpuhelinnumero

+358 09 471 977

Carechem 24 International

+33 1 72 11 00 03

Numéro d'appel d'urgence

+33 (0)1 45 42 5959

Carechem 24 International

+44 1235 239670

Carechem 24 International

+30 21 1198 3182

Díjmentesen hívható zöld szám

+36 80 20 11 99

Carechem 24 International

+39 02 3604 2884

Numeri telefonici dei principali CAV (FI)

055 7947819

Numeri telefonici dei principali CAV (MI)

02 66101029

Numeri telefonici dei principali CAV (PV)

038 224444

Numeri telefonici dei principali CAV (RM)

06 3054343

Numeri telefonici dei principali CAV (NA)

081 7472870

Emergency telephone number

+353 1 809 2166

Valsts Toksikoloģijas centra Saindešanās un zāļu informācijas centrs

+371 6704 2473

Neatidēliotina informācija apsinuodijus

+370 5 236 20 52

Carechem 24 International

+31 10 713 8195

National Poisons Information Center (NL)

+31 30 274 88 88

Carechem 24 International

+47 2103 4452

Giftinformasjon

+47 22 59 13 00

Carechem 24 International

+48 22 307 3690

Emergency Contact

112

Carechem 24 International

+351 30880 4750

Número de telefone de emergência

+351 808 250 143

Număr de telefon care poate fi apelat în caz de urgență

+021 318 36 06

08:00-15:00

Národné toxikologické informačné centrum

+421 2 5477 4166

Carechem 24 International

+27 21 300 2732

Carechem 24 International

+34 91 114 2520

Carechem 24 International

+46 8 566 42573

Emergency Contact

112

Emergency Contact

145

Emergency Contact

+41 44 251 51 51

Carechem 24 International

+90 212 375 5231

Ulusal Zehir Danışma Merkezi (UZEM)

114

Acil Sağlık Hizmetleri

112

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Eye Dam. Cat. 1 H318

GHS Pictograms

GHS05 - Corrosive

GHS05

Hazard Statements

H318 Causes serious eye damage

Precautionary Statements

P280 Wear eye protection/ face protection
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
P310 Immediately call a POISON CENTER or doctor/physician
P501 Dispose of contents/ container to an approved waste disposal plant

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Highly refined base oil (Viscosity >20.5 cSt @40°C) --- 25 - 50% No
Highly refined, low viscosity mineral oils/hydrocarbons (Viscosity >7 - <20.5 cSt @40°C) --- 10 - 25% Yes
Fatty acids, C16-18 and C18-unsatd., compds. with triethanolamine EC: 270-279-3 68424-19-1 2.5 - 10% Yes
Alcohols, C12-15, ethoxylated, phosphates 68071-35-2 2.5 - 10% Yes
2-Amino-2-methylpropanol EC: 204-709-8 124-68-5 1 - 2.5% Yes
Alcohols, C12-13, ethoxylated (5 - 7EO) 66455-14-9 1% Yes
Alcohols, C12-15, ethoxylated EC: 500-195-7 68131-39-5 1% Yes
Alcohols, C12-13, ethoxylated (2.5 - 5EO) 66455-14-9 1% Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air.

Skin contact

Wash off immediately with soap and plenty of water. Remove and wash contaminated clothing before re-use.

Eye contact

Immediately flush with plenty of water. After initial flushing, remove any contact lenses and continue flushing for at least 15 minutes. Keep eye wide open while rinsing. Do not rub affected area. Seek immediate medical attention/advice.

Symptoms: Eye damage/irritation

Ingestion

Clean mouth with water. Drink plenty of water. Do not induce vomiting without medical advice.

Immediate Medical Attention

Immediate medical attention is required.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment; Use CO2, dry chemical, or foam, Water spray or fog, Cool containers / tanks with water spray

Unsuitable media

Do not use a solid water stream as it may scatter and spread fire

Specific hazards

In the event of fire and/or explosion do not breathe fumes. Carbon monoxide, carbon dioxide and unburned hydrocarbons (smoke). Thermal decomposition can lead to release of irritating gases and vapors.

Firefighter Protection

As in any fire, wear self-contained breathing apparatus pressure-demand, MSHA/NIOSH (approved or equivalent) and full protective gear

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Remove all sources of ignition. Ensure adequate ventilation. Use personal protective equipment. Avoid contact with skin, eyes and clothing. Evacuate personnel to safe areas.

Large spill

Dike to collect large liquid spills.

Environmental

Prevent further leakage or spillage if safe to do so.

Cleanup methods

Soak up with inert absorbent material

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from open flames, hot surfaces and sources of ignition. Handle in accordance with good industrial hygiene and safety practice. Ensure adequate ventilation. Do not eat, drink or smoke when using this product. Wear personal protective equipment. Avoid contact with skin, eyes and clothing.

Storage

Keep containers tightly closed in a dry, cool and well-ventilated place.

Hygiene

Handle in accordance with good industrial hygiene and safety practice. Do not eat, drink or smoke when using this product.

Fire prevention

Keep away from open flames, hot surfaces and sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Ensure adequate ventilation, especially in confined areas. Eyewash stations.

Hands

For operations where prolonged or repeated skin contact may occur, impervious gloves should be worn. The following glove type may be suitable for handling this product: Protective gloves complying with EN 374. Nitrile rubber Glove thickness => 0.38 mm Break through time => 480 min Butyl rubber Glove thickness => 0.64 mm Break through time => 480 min Glove material suitability will vary depending on specific use conditions. Consideration should be given to variables such as operational characteristics, anticipated contact time, task requirements and other factors relevant to the selection of PPE. Please observe the instructions regarding permeability and breakthrough time which are provided by the supplier of the gloves. Also take into consideration the specific local conditions under which the product is used, such as the danger of cuts, abrasion. Any specific glove information provided is based on published literature and glove manufacturer data. Barrier creams may help to protect the exposed areas of skin. Barrier creams should not be applied after exposure has occurred. Gloves should be replaced regularly and if there is any sign of damage to the glove material.

Eyes

Tightly fitting safety goggles. Eye protection must conform to standard EN 166.

Respiratory

No special protective equipment required. In case of mist, spray or aerosol exposure wear suitable personal respiratory protection and protective suit.

Skin/Body

Long sleeved clothing.

Environmental

No special environmental precautions required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
clear yellow
Colour
---
Colour Intensity
---
Form
---
Odor
Characteristic
Odor Threshold
Not Determined
Ph
~ 8.3
Melting Point
Not Determined
Boiling Point
Not Determined
Flash Point
>= 140 °C / >= 284 °F (ASTM D 93)
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not Determined
Vapor Pressure
Not Determined
Vapor Density
Not Determined
Relative Density
0.91 g/cm3 @20°C
Bulk Density
---
Density
---
Flammability
Not Determined
Upper Explosive Limit
Not Determined
Lower Explosive Limit
Not Determined
Explosive Limits
---
Auto Ignition Temperature
Not Determined
Decomposition Temperature
Not Determined
Solubility
---
Partition Coefficient
Not Determined
Solubility In Water
Emulsifies
Solubility In Fat
---
Molecular Weight
---
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
---
Kinematic Viscosity
~ 34 mm2/s @ 40 °C
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under normal conditions

Reactivity

None under normal use conditions

Hazardous reactions

None under normal use conditions

Avoid

Keep away from open flames, hot surfaces and sources of ignition. Extremes of temperature and direct sunlight.

Incompatible

Strong oxidizing agents, Strong acids, Strong bases

Decomposition

Incomplete combustion and thermolysis produces potentially toxic gases such as carbon monoxide and carbon dioxide.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Tandemol H 674 I-LV?

The signal word is danger.

What is the physical form of Tandemol H 674 I-LV?

Tandemol H 674 I-LV is a liquid appearing as clear yellow . It has characteristic odor.

What is Tandemol H 674 I-LV used for?

Rolling Additive

What are the hazard statements for Tandemol H 674 I-LV?

This substance has 1 hazard statement:

  • H318: Causes serious eye damage

What is the melting point of Tandemol H 674 I-LV?

The melting point is Not Determined and the boiling point is Not Determined.