NextSDS Logo
Safety Data Sheet EN

BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Lubricant

Uses advised against

None identified

Manufacturers & Suppliers

Henkel Corporation logo

Henkel Corporation

manufacturer

One Henkel Way, Rocky Hill, Connecticut 06067

+1 (860) 571-5100

http://www.henkelna.com

Emergency Contacts

Poison Control Center

1-877-671-4608

Poison Control Center

1-303-592-1711

CHEMTREC

1-800-424-9300

CHEMTREC

1-703-527-3887

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2
Eye Irrit. Cat. 2A
STOT SE Cat. 3

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 HIGHLY FLAMMABLE LIQUID AND VAPOUR.
H319 CAUSES SERIOUS EYE IRRITATION.
H336 MAY CAUSE DROWSINESS OR DIZZINESS.

Precautionary Statements

P210 Keep away from heat, sparks, open flames, hot surfaces - no smoking.
P233 Keep container tightly closed.
P240 Ground and bond container and receiving equipment.
P241 Use explosion-proof equipment.
P242 Use non-sparking tools.
P243 Take action to prevent static discharges.
P261 Avoid breathing mist/vapours.
P264 Wash affected area thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves, clothing, eye and face protection.
P303 + P361 + P353 If on skin (or hair): Take off immediately all contaminated clothing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337 + P313 If eye irritation persists: Get medical attention.
P370 + P378 In case of fire: Use foam, dry chemical or carbon dioxide to extinguish.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P403 + P235 Store in a well-ventilated place. Keep cool.
P405 Store locked up.
P501 Dispose of contents and/or container according to Federal, State/Provincial and local governmental regulations.
IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or physician if you feel unwell.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
2-Propanol 67-63-0 60 - 80% Yes
n-butyl acetate 123-86-4 1 - 5% Yes
Ethene, tetrafluoro-, homopolymer 9002-84-0 10 - 30% Yes

Notes

* Exact percentages may vary or are trade secret. Concentration range is provided to assist users in providing appropriate protections.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person immediately to fresh air. Seek medical attention if symptoms develop or persist.

Skin contact

Immediately wash skin thoroughly with soap and water. Seek medical advice.

Eye contact

Immediately flush eyes with water for at least 15 minutes, while holding eyelids open. Seek medical attention at once.

Ingestion

Get immediate medical attention. DO NOT induce vomiting unless directed to do so by medical personnel.

Immediate Medical Attention

Get immediate medical attention.

Medical Treatment

Treat symptomatically and supportively.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Water spray (fog), foam, dry chemical or carbon dioxide.

Unsuitable media

Not available.

Specific hazards

Fire and Explosion hazards are DANGEROUS when this material is exposed to heat or flame. May liberate large quantities of dense, foul-smelling smoke which may contain unidentified toxic gasses.

Instructions

Wear full protective clothing. Wear self-contained breathing apparatus.

Firefighter Protection

Wear full protective clothing. Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Use personal protection recommended in Section 8, isolate the hazard area and deny entry to unnecessary and unprotected personnel.

Environmental

Do not allow product to enter sewer or waterways.

Cleanup methods

Remove all sources of ignition. Ensure adequate ventilation. Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). Scrape up spilled material and place in a closed container for disposal.

Materials: sand, silica gel, acid binder, universal binder, sawdust

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid contact with eyes, skin and clothing. Wash thoroughly after handling. Avoid breathing vapors or mists of this product. Ground and bond all equipment as required (when transferring products). Keep away from heat, spark and flame. Use only with adequate ventilation. Do not take internally. For industrial use only.

Storage

Store in a cool, dry, well-ventilated area. Keep away from heat, spark and flame. Keep container closed. Store in original container until ready to use. Protect from direct sunlight.

Hygiene

Wash thoroughly after handling.

Fire prevention

Keep away from heat, spark and flame. Ground and bond all equipment as required (when transferring products). Ground and bond metal containers for liquid transfer to avoid static sparks.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
Off white
Colour Intensity
---
Form
---
Odor
Solvent
Odor Threshold
Not available.
Ph
Not applicable
Melting Point
Not available.
Boiling Point
82.3 °C (180.1 °F) calculated
Flash Point
11.6 °C (52.88 °F) calculated
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
1 (Butyl acetate = 1)
Vapor Pressure
33 mm hg
Vapor Density
---
Relative Density
---
Bulk Density
---
Density
0.864 - 0.924
Flammability
Not applicable
Upper Explosive Limit
12 %
Lower Explosive Limit
1.2 %
Explosive Limits
---
Auto Ignition Temperature
> 398 °C (> 748.4 °F)
Decomposition Temperature
Not available.
Solubility
Disperses in water as a suspension Water
Partition Coefficient
Not available.
Solubility In Water
---
Solubility In Fat
---
Molecular Weight
---
Voc Content
683 g/l
Metal Corrosion
---
Dynamic Viscosity
20 - 50 cp
Kinematic Viscosity
Not available.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable at normal conditions.

Reactivity

Not available.

Hazardous reactions

None under normal processing.

Avoid

Avoid excessive heat and ignition sources.

Incompatible

This product may react with oxidizing agents.

Decomposition

Upon decomposition, this product emits carbon monoxide, carbon dioxide and/or low molecular weight hydrocarbons.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1263
Shipping Name
Paint
Transport Class
3
Packing Group
II
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309?

The signal word is danger.

What is the physical form of BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309?

BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309 is a liquid with off white color. It has solvent odor.

What is the solubility of BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309?

Disperses in water as a suspension Water

What is BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309 used for?

Lubricant

What are the hazard statements for BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309?

This substance has 3 hazard statements:

  • H225: HIGHLY FLAMMABLE LIQUID AND VAPOUR.
  • H319: CAUSES SERIOUS EYE IRRITATION.
  • H336: MAY CAUSE DROWSINESS OR DIZZINESS.

What is the melting point of BONDERITE S-FN 309 DRYFILM COATING ACHESON known as EMRALON309?

The melting point is Not available. and the boiling point is 82.3 °C (180.1 °F) calculated.