Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SIGMADUR 520/550 HARDENER
- Product Form
- Liquid.
- Product Code
- O1500467483
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Hardener. Professional applications, Used by spraying, Application by non spray methods.
Manufacturers & Suppliers
PPG Industries (Singapore) Pte. Ltd.
manufacturer
No. 1 Tuas Basin Close, Singapore 638803.
+65 68653737
Emergency Contacts
CHEMTREC
+(65)-31581349
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
CAS number: Not applicable. EC number: Mixture.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| 1,2,4-trimethylbenzene | 95-63-6 | 1 - 3% | No |
| Hexamethylene diisocyanate, oligomers. | 28182-81-2 | 50 - 100% | No |
| xylene | 1330-20-7 | 10 - 20% | No |
| n-butyl acetate | 123-86-4 | 3 - 5% | No |
| ethylbenzene | 100-41-4 | 1 - 3% | No |
| Solvent naphtha (petroleum), light aromatic | 64742-95-6 | 1 - 3% | No |
Occupational exposure limits, if available, are listed in Section 8. SUB codes represent substances without registered CAS Numbers.
Notes
There are no additional ingredients present which, within the current knowledge of the supplier and in the concentrations applicable, are classified as hazardous to health or the environment and hence require reporting in this section.
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove to fresh air. Keep person warm and at rest. If not breathing, if breathing is irregular or if respiratory arrest occurs, provide artificial respiration or oxygen by trained personnel.
Symptoms: Harmful if inhaled. May cause respiratory irritation. Adverse symptoms may include the following: respiratory tract irritation, coughing.
Remove contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognized skin cleanser. Do NOT use solvents or thinners.
Symptoms: Causes skin irritation. Defatting to the skin. May cause an allergic skin reaction. Adverse symptoms may include the following: irritation, redness, dryness, cracking.
Remove contact lenses, irrigate copiously with clean, fresh water, holding the eyelids apart for at least 10 minutes and seek immediate medical advice.
Symptoms: Causes serious eye irritation. Adverse symptoms may include the following: pain or irritation, watering, redness.
If swallowed, seek medical advice immediately and show this container or label. Keep person warm and at rest. Do NOT induce vomiting.
Symptoms: No known significant effects or critical hazards.
Immediate Medical Attention
Seek immediate medical advice.
Medical Treatment
No specific treatment.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use dry chemical, CO₂, water spray (fog) or foam.
Do not use water jet.
Flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard. In a fire or if heated, a pressure increase will occur and the container may burst, with the risk of a subsequent explosion.
Promptly isolate the scene by removing all persons from the vicinity of the incident if there is a fire. No action shall be taken involving any personal risk or without suitable training. Move containers from fire area if this can be done without risk. Use water spray to keep fire-exposed containers cool.
Firefighter Protection
Fire-fighters should wear appropriate protective equipment and self-contained breathing apparatus (SCBA) with a full face-piece operated in positive pressure mode.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Shut off all ignition sources. No flares, smoking or flames in hazard area. Avoid breathing vapor or mist. Provide adequate ventilation.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Dilute with water and mop up if water-soluble. Alternatively, or if water-insoluble, absorb with an inert dry material and place in an appropriate waste disposal container. Dispose of via a licensed waste disposal contractor.
Stop leak if without risk. Move containers from spill area. Use spark-proof tools and explosion-proof equipment. Approach release from upwind. Prevent entry into sewers, water courses, basements or confined areas. Wash spillages into an effluent treatment plant or proceed as follows. Contain and collect spillage with non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth and place in container for disposal according to local regulations (see Section 13). Dispose of via a licensed waste disposal contractor.
Avoid dispersal of spilled material and runoff and contact with soil, waterways, drains and sewers.
The contaminated area should be cleaned immediately with a suitable decontaminant. Add the same decontaminant to the remnants and let stand for several days until no further reaction in an unsealed container. Once this stage is reached, close container and dispose of according to local regulations.
Materials: non-combustible, absorbent material e.g. sand, earth, vermiculite or diatomaceous earth
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Put on appropriate personal protective equipment (see Section 8). Persons with a history of skin sensitization problems should not be employed in any process in which this product is used. Do not get in eyes or on skin or clothing. Do not ingest. Avoid breathing vapor or mist. Use only with adequate ventilation. Wear appropriate respirator when ventilation is inadequate. Do not enter storage areas and confined spaces unless adequately ventilated. Keep in the original container or an approved alternative made from a compatible material, kept tightly closed when not in use. Store and use away from heat, sparks, open flame or any other ignition source. Use explosion-proof electrical (ventilating, lighting and material handling) equipment. Use only non-sparking tools. Take precautionary measures against electrostatic discharges. Empty containers retain product residue and can be hazardous. Do not reuse container.
Store between the following temperatures: 0 to 35°C (32 to 95°F). Store in accordance with local regulations. Store in a segregated and approved area. Store in original container protected from direct sunlight in a dry, cool and well-ventilated area, away from incompatible materials (see Section 10) and food and drink. Store locked up. Eliminate all ignition sources. Separate from oxidizing materials. Keep container tightly closed and sealed until ready for use. Containers that have been opened must be carefully resealed and kept upright to prevent leakage. Do not store in unlabeled containers. Use appropriate containment to avoid environmental contamination. Precautions should be taken to minimize exposure to atmospheric humidity or water. CO₂ will be formed, which, in closed containers, could result in pressurization.
Eating, drinking and smoking should be prohibited in areas where this material is handled, stored and processed. Workers should wash hands and face before eating, drinking and smoking. Remove contaminated clothing and protective equipment before entering eating areas.
Store and use away from heat, sparks, open flame or any other ignition source. Eliminate all ignition sources. Take precautionary measures against electrostatic discharges.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use only with adequate ventilation. Use process enclosures, local exhaust ventilation or other engineering controls to keep worker exposure to airborne contaminants below any recommended or statutory limits. The engineering controls also need to keep gas, vapor or dust concentrations below any lower explosive limits. Use explosion-proof ventilation equipment.
Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Considering the parameters specified by the glove manufacturer, check during use that the gloves are still retaining their protective properties. It should be noted that the time to breakthrough for any glove material may be different for different glove manufacturers. In the case of mixtures, consisting of several substances, the protection time of the gloves cannot be accurately estimated. Gloves : butyl rubber
Chemical splash goggles.
Use an air-fed respirator unless a site-specific assessment determines that an air-fed respirator is not necessary, in which case the results of the risk assessment should be utilized to determine whether respiratory protection is necessary and what type of protection is appropriate. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.
Personal protective equipment for the body should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product. When there is a risk of ignition from static electricity, wear anti-static protective clothing. For the greatest protection from static discharges, clothing should include anti-static overalls, boots and gloves. Other skin protection : Appropriate footwear and any additional skin protection measures should be selected based on the task being performed and the risks involved and should be approved by a specialist before handling this product.
Emissions from ventilation or work process equipment should be checked to ensure they comply with the requirements of environmental protection legislation. In some cases, fume scrubbers, filters or engineering modifications to the process equipment will be necessary to reduce emissions to acceptable levels.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable.
No specific test data related to reactivity available for this product or its ingredients.
Under normal conditions of storage and use, hazardous reactions will not occur.
In a fire, hazardous decomposition products may be produced.
Keep away from: oxidizing agents, strong alkalis, strong acids, amines, alcohols, water. Uncontrolled exothermic reactions occur with amines and alcohols.
Depending on conditions, decomposition products may include the following materials: Cyanate and isocyanate. carbon oxides nitrogen oxides hydrogen cyanide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
Toxicity
Toxicity
Toxicity
Toxicity
Persistence/degradability
Persistence/degradability
Persistence/degradability
Persistence/degradability
Persistence/degradability
Persistence/degradability
Bioaccumulative potential
Bioaccumulative potential
Bioaccumulative potential
Bioaccumulative potential
Bioaccumulative potential
Mobility in soil
Other adverse effects
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Dispose of surplus and non-recyclable products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction.
The generation of waste should be avoided or minimized wherever possible. Disposal of this product, solutions and any by-products should at all times comply with the requirements of environmental protection and waste disposal legislation and any regional local authority requirements.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1263
- Shipping Name
- PAINT
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SIGMADUR 520/550 HARDENER?
The signal word is warning.
What is the physical form of SIGMADUR 520/550 HARDENER?
SIGMADUR 520/550 HARDENER is a liquid. appearing as colorless, aromatic with colorless. color. It has aromatic. [slight] odor.
What is SIGMADUR 520/550 HARDENER used for?
Hardener. Professional applications, Used by spraying, Application by non spray methods.
What are the hazard statements for SIGMADUR 520/550 HARDENER?
This substance has 6 hazard statements:
- H226: Flammable liquid and vapor.
- H315: Causes skin irritation.
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
- H332: Harmful if inhaled.
- H335: May cause respiratory irritation.