Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- Kühlflüssigkeit ME-KM 21
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Coolant Industrial uses
Uses advised against
No information available.
Manufacturers & Suppliers
Merkle Schweißanlagen-Technik GmbH
manufacturer
Industriestraße 3, D-89359 Kötz
08221 915-0
Emergency Contacts
Emergency Contact
+49(0)8221 915-0
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
GHS08
Hazard Statements
Precautionary Statements
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| ethanediol, ethylene glycol EC: 203-473-3 | 107-21-1 | 25 - 30% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air and keep comfortable for breathing. If unconscious place in recovery position and seek medical advice. If breathing is irregular or stopped, administer artificial respiration.
After contact with skin, wash immediately with plenty of water and soap. Remove contaminated, saturated clothing immediately.
After contact with the eyes, rinse with water with the eyelids open for a sufficient length of time, then consult an ophthalmologist immediately. Remove contact lenses, if present and easy to do. Continue rinsing.
If accidentally swallowed rinse the mouth with plenty of water (only if the person is conscious) and obtain immediate medical attention. Let water be drunken in little sips (dilution effect). Do NOT induce vomiting.
Immediate Medical Attention
Seek medical advice immediately in case of accident or unwellness. Obtain immediate medical attention if swallowed. Consult an ophthalmologist immediately after eye contact.
Medical Treatment
First Aid, decontamination, treatment of symptoms.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Dry extinguishing powder, alcohol resistant foam, Carbon dioxide (CO2), Water spray jet
Full water jet
Carbon monoxide Carbon dioxide (CO2) Nitrogen oxides (NOx)
Firefighter Protection
In case of fire: Wear self-contained breathing apparatus.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Provide fresh air.
Do not allow to enter into surface water or drains. Do not allow to enter into soil/subsoil. Shafts and sewers must be protected from entry of the product.
Absorb with liquid-binding material
Materials: sand, diatomaceous earth, acid- or universal binding agents
Related Products
Similar products with comparable safety profiles
Kühlöl, Typ Isoflex PDP 38
---
MPM Coolant Premium Longlife -40°C G13 Ready to Use
UFI: QSKQ-5GAP-320Q-7KES
AUTOL SPEZIAL FLUID N15
UFI: CM90-V041-Y009-WUE4
FM HEAT TRANSFER FLUID 32
---
Eurol Antifreeze G11
UFI: HDYX-Y24E-EA0N-XWDF
Kroon-Oil Coolant SP 12 EVO
UFI: HP60-79J0-G000-MWMC
7795 - Coolant LL G11 VW 774C
---
METALUBE COOL FLUID AERO
UFI: F6H7-M05K-W000-888T
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
See
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Provide adequate ventilation as well as local exhaustion at critical locations. Ground and bond container and receiving equipment. Carry out filling operations only at stations with exhaust ventilation facilities. Make available sufficient washing facilities Provide eye shower and label its location conspicuously
Tested protective gloves must be worn: EN ISO 374 NBR (Nitrile rubber) NR (natural rubber, natural latex) Butyl caoutchouc (butyl rubber) Thickness of the glove material >= 0,4 mm Breakthrough times and swelling properties of the material must be taken into consideration. For special purposes, it is recommended to check the resistance to chemicals of the protective gloves mentioned above together with the supplier of these gloves. Wearing time with occasional contact (splashes): max. 480 min. (NBR (Nitrile rubber)) Wearing time with permanent contact 240 - 480 min (NBR (Nitrile rubber)) Observe the wear time limits as specified by the manufacturer. Wear cotton undermitten if possible.
Eye glasses with side protection, goggles
If technical exhaust or ventilation measures are not possible or insufficient, respiratory protection must be worn. Suitable respiratory protection apparatus: Full-/half-/quarter-face masks (DIN EN 136/140) ABEK-P3
Protective clothing. (liquid-tight) Wear anti-static footwear and clothing Street clothing should be stored separately from work clothing. Take off immediately all contaminated clothing and wash it before reuse.
No information available.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The product is stable under storage at normal ambient temperatures.
No information available.
Reacts with: Oxidising agent, strong, sulphuric acid
Keep away from sources of heat (e.g. hot surfaces), sparks and open flames.
Oxidising agent, strong; Strong acid; Strong alkali
Carbon dioxide, Carbon monoxide
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for Kühlflüssigkeit ME-KM 21?
The signal word is warning.
What is the physical form of Kühlflüssigkeit ME-KM 21?
Kühlflüssigkeit ME-KM 21 is a liquid with colourless color. It has characteristic odor.
What is Kühlflüssigkeit ME-KM 21 used for?
Coolant Industrial uses
What are the hazard statements for Kühlflüssigkeit ME-KM 21?
This substance has 2 hazard statements:
- H302: Harmful if swallowed.
- H373: May cause damage to organs through prolonged or repeated exposure.
What is the melting point of Kühlflüssigkeit ME-KM 21?
The melting point is not determined and the boiling point is not determined.