NextSDS Logo
Safety Data Sheet EN

Tectyl® MULTIPURPOSE AMBER RUST PREVENTATIVE

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Tectyl® MULTIPURPOSE AMBER RUST PREVENTATIVE
Product Code
887100

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Corrosion inhibitor.

Manufacturers & Suppliers

E

Ellis Enterprises B.V., an affiliate of Valvoline

manufacturer

Wieldrechtseweg 39 3316 BG Dordrecht Netherlands

+31 (0)78 654 3500

Emergency Contacts

Emergency Contact

00-800-825-8654

Emergency Contact

001-859-202-3865

Emergency Contact

+31 030 274 88 88

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Aerosol Cat. 1 H222
Aerosol Cat. 1 H229
STOT SE Cat. 3 H336

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H222 Extremely flammable aerosol.
H229 Pressurised container: May burst if heated.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P101 If medical advice is needed, have product container or label at hand.
P102 Keep out of reach of children.
P210 Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking.
P211 Do not spray on an open flame or other ignition source.
P251 Do not pierce or burn, even after use.
P271 Use only outdoors or in a well-ventilated area.
P405 Store locked up.
P410 + P412 Protect from sunlight. Do not expose to temperatures exceeding 50 °C/ 122 °F.
P501 Dispose of contents/ container to an approved waste disposal plant.

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
(2-Methoxymethylethoxy)propanol EC: 252-104-2 34590-94-8 1 - 2.5% No
Propane EC: 200-827-9 74-98-6 25 - 40% Yes
Hydrocarbons, C9-C11, n-alkanes, iso-alkanes, cyclenes, <2% aromatics EC: 919-857-5 64742-48-9 20 - 25% Yes
Butane EC: 203-448-7 106-97-8 15 - 25% Yes
Sulfonic acids, petroleum, sodium salts EC: 271-781-5 68608-26-4 1 - 2.5% Yes
2-(2-Heptadec-8-enyl-2-imidazolin-1-yl)ethanol EC: 202-414-9 95-38-5 0.1 - 0.25% Yes
(Z)-N-Methyl-N-(1-oxo-9-octadecenyl)glycine EC: 203-749-3 110-25-8 0.1 - 0.25% Yes
Distillates (petroleum), hydrotreated light naphthenic EC: 265-156-6 64742-53-6 1 - 2.5% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Move to fresh air. If unconscious, place in recovery position and seek medical advice. Consult a physician after significant exposure.

Symptoms: drowsiness or dizziness

Skin contact

First aid is not normally required. However, it is recommended that exposed areas be cleaned by washing with soap and water.

Eye contact

Flush eyes with water as a precaution. Remove contact lenses. Protect unharmed eye. If eye irritation persists, consult a specialist.

Ingestion

Do not give milk or alcoholic beverages. Never give anything by mouth to an unconscious person. If symptoms persist, call a physician.

Immediate Medical Attention

No hazards which require special first aid measures.

Medical Treatment

No hazards which require special first aid measures.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Water spray, Foam, Alcohol-resistant foam, Carbon dioxide (CO2), Dry chemical

Unsuitable media

High volume water jet

Specific hazards

Never use welding or cutting torch on or near drum (even empty) because product (even just residue) can ignite explosively. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas.

Instructions

Use a water spray to cool fully closed containers.

Firefighter Protection

In the event of fire, wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate personnel to safe areas. Remove all sources of ignition. Ensure adequate ventilation. Beware of vapours accumulating to form explosive concentrations. Vapours can accumulate in low areas. Persons not wearing protective equipment should be excluded from area of spill until clean-up has been completed.

Environmental

Prevent product from entering drains. Prevent further leakage or spillage if safe to do so.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Open drum carefully as content may be under pressure. Do not breathe vapours/dust. Do not smoke. Container hazardous when empty. Avoid exposure - obtain special instructions before use. For personal protection see section 8.

Storage

Keep container tightly closed in a dry and well-ventilated place. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Keep away from direct sun exposure and temperatures over 50 °C.

Hygiene

Wash hands before breaks and at the end of workday. Smoking, eating and drinking should be prohibited in the application area.

Fire prevention

Take necessary action to avoid static electricity discharge (which might cause ignition of organic vapours). Keep away from open flames, hot surfaces and sources of ignition.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Provide sufficient mechanical (general and/or local exhaust) ventilation to maintain exposure below exposure guidelines (if applicable) or below levels that cause known, suspected or apparent adverse effects.

Hands

Material: nitrile rubber; Break through time: 480 min; Glove thickness: 0,38 mm; Remarks: The selected protective gloves have to satisfy the specifications of Regulation (EU) 2016/425 and the standard EN 374 derived from it. The suitability for a specific workplace should be discussed with the producers of the protective gloves.

Eyes

Not required under normal conditions of use. Wear splash-proof safety goggles if material could be misted or splashed into eyes.

Respiratory

In the case of vapour formation use a respirator with an approved filter. In the case of dust or aerosol formation use respirator with an approved filter. Filter type: Combined particulates, organic gas and low boiling vapour type (AX-P)

Skin/Body

Wear as appropriate: Impervious clothing, Safety shoes, Flame-resistant clothing. Choose body protection according to the amount and concentration of the dangerous substance at the work place.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Bulk Density
---
Physical State
aerosol
State Under Standard Conditions
---
Evaporation Rate
No data available
Colour Intensity
---
Density
ca. 0,70 g/cm3 (20 °C)
Upper Explosive Limit
No data available
Crystallisation Point
---
Properties Status
---
Lower Explosive Limit
No data available
Solubility
---
Relative Density
No data available
Molecular Weight
---
Solidification Point
---
Cloud Point
---
Dynamic Viscosity
No data available
Kinematic Viscosity
No data available
Metal Corrosion
---
Flash Point
< 0 °C
Colour
amber
Voc Content
---
Appearance
aerosol
Explosive Limits
---
Physical State Data
aerosol
Flammability
No data available
Vapor Density
---
Ph
Not applicable
Auto Ignition Temperature
No data available
Partition Coefficient
No data available
Boiling Point
No data available
Solubility In Fat
---
Vapor Pressure
No data available
Freezing Point
---
Odor
solvent-like
Form
---
Odor Threshold
No data available
Melting Point
No data available
Decomposition Temperature
No data available
Relative Evaporation Rate
---
Softening Point
---
Solubility In Water
insoluble
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable under recommended storage conditions.

Reactivity

No decomposition if stored and applied as directed.

Hazardous reactions

Vapours may form explosive mixture with air.

Avoid

Heat, flames and sparks. excessive heat. Do not allow evaporation to dryness. Exposure to air.

Incompatible

Acids, Oxidizing agents, salts of strong bases, strong bases

Decomposition

No hazardous decomposition products are known.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
1950
Shipping Name
AEROSOLS
Transport Class
2
Packing Group
Not assigned by regulation
15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Tectyl® MULTIPURPOSE AMBER RUST PREVENTATIVE?

The signal word is danger.

What is the physical form of Tectyl® MULTIPURPOSE AMBER RUST PREVENTATIVE?

Tectyl® MULTIPURPOSE AMBER RUST PREVENTATIVE is a aerosol appearing as aerosol with amber color. It has solvent-like odor.

What is Tectyl® MULTIPURPOSE AMBER RUST PREVENTATIVE used for?

Corrosion inhibitor.

What are the hazard statements for Tectyl® MULTIPURPOSE AMBER RUST PREVENTATIVE?

This substance has 3 hazard statements:

  • H222: Extremely flammable aerosol.
  • H229: Pressurised container: May burst if heated.
  • H336: May cause drowsiness or dizziness.

What is the melting point of Tectyl® MULTIPURPOSE AMBER RUST PREVENTATIVE?

The melting point is No data available and the boiling point is No data available.