Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 3M Surface Preparation System
- Product Code
- DR-5000-0214-9
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
Surface cleaner.
Manufacturers & Suppliers
3M Ireland Limited
manufacturer
The Iveagh Building, The Park, Carrickmines, Dublin 18.
+353 1 280 3555
http://www.3M.com
Emergency Contacts
National Poisons Information Centre, Beaumont Hospital, Dublin 9 DOV2NO, Ireland
+353 (0)1 809 2166
8am-10pm (seven days)
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS02
GHS07
GHS08
GHS09
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Naphtha (petroleum), hydrotreated heavy EC: 265-150-3 | 64742-48-9 | 50 - 100% | Yes |
| (2-Methoxymethylethoxy)propanol EC: 252-104-2 | 34590-94-8 | 1 - 15% | No |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove person to fresh air. If you feel unwell, get medical attention.
Immediately flush skin with large amounts of cold water for at least 15 minutes. DO NOT ATTEMPT TO REMOVE MOLTEN MATERIAL. Cover affected area with a clean dressing. Get immediate medical attention.
Immediately flush eyes with large amounts of water for at least 15 minutes. DO NOT ATTEMPT TO REMOVE MOLTEN MATERIAL. Get immediate medical attention.
Do not induce vomiting. Get immediate medical attention.
Immediate Medical Attention
Get immediate medical attention.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
Use a fire fighting agent suitable for flammable liquids such as dry chemical or carbon dioxide to extinguish.
Water may not effectively extinguish fire
Closed containers exposed to heat from fire may build pressure and explode.
Water should be used to keep fire-exposed containers and surfaces cool and prevent explosive rupture.
Firefighter Protection
Wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Evacuate area. Eliminate all ignition sources if safe to do so. Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
For large spill, or spills in confined spaces, provide mechanical ventilation to disperse or exhaust vapours, in accordance with good industrial hygiene practice.
Avoid release to the environment.
Collect as much of the spilled material as possible using non-sparking tools. Place in a metal container approved for transportation by appropriate authorities. Clean up residue with an appropriate solvent selected by a qualified and authorised person. Ventilate the area with fresh air. Seal the container.
Materials: non-sparking tools, metal container, appropriate solvent
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid skin contact with hot material. For industrial/occupational use only. Not for consumer sale or use. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing dust/fume/gas/mist/vapours/spray. Do not get in eyes, on skin, or on clothing. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid release to the environment. Avoid contact with oxidising agents (eg. chlorine, chromic acid etc.) Wear low static or properly grounded shoes.
Store in a well-ventilated place. Keep cool. Keep container tightly closed. Store away from heat.
Do not eat, drink or smoke when using this product. Wash thoroughly after handling.
Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Take precautionary measures against static discharge. Ground/bond container and receiving equipment if there is potential for static electricity accumulation during transfer.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Use general dilution ventilation and/or local exhaust ventilation to control airborne exposures to below relevant Exposure Limits and/or control dust/fume/gas/mist/vapours/spray. If ventilation is not adequate, use respiratory protection equipment. Use explosion-proof ventilation equipment.
Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the results of an exposure assessment. Selection should be based on use factors such as exposure levels, concentration of the substance or mixture, frequency and duration, physical challenges such as temperature extremes, and other use conditions. Consult with your glove and/or protective clothing manufacturer for selection of appropriate compatible gloves/protective clothing. Note: Nitrile gloves may be worn over polymer laminate gloves to improve dexterity. Gloves made from the following material(s) are recommended: Polymer laminate. Use gloves tested to EN 374.
Full face shield. Indirect vented goggles. Use eye protection conforming to EN 166
Half facepiece or full facepiece air-purifying respirator suitable for organic vapours. Use a respirator conforming to EN 140 or EN 136: filter type A
Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the results of an exposure assessment.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Stable.
This material is considered to be non reactive under normal use conditions
Hazardous polymerisation will not occur.
Sparks and/or flames. Heat.
Strong oxidising agents.
None known. Refer to section 5.2 for hazardous decomposition products during combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- UN1268
- Shipping Name
- PETROLEUM DISTILLATES, N.O.S.(HYDROTREATED HEAVY NAPHTHA (PETROLEUM))
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 3M Surface Preparation System?
The signal word is danger.
What is the physical form of 3M Surface Preparation System?
3M Surface Preparation System is a liquid. with colourless color. It has slight odor odor.
What is the solubility of 3M Surface Preparation System?
No data available.
What is 3M Surface Preparation System used for?
Surface cleaner.
What are the hazard statements for 3M Surface Preparation System?
This substance has 5 hazard statements:
- H226: Flammable liquid and vapour.
- H304: May be fatal if swallowed and enters airways.
- H315: Causes skin irritation.
- H336: May cause drowsiness or dizziness.
- H411: Toxic to aquatic life with long lasting effects.
What is the melting point of 3M Surface Preparation System?
The melting point is Not applicable. and the boiling point is >179 °C.