Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- 605100 R11634A
Regulatory Identifiers
- CAS Number
- N/A
- UFI Code
- 0845-701W-000W-4SAC
Identified Uses
Heavy Duty Diesel
Uses advised against
None identified.
Manufacturers & Suppliers
LUBRIZOL FRANCE
manufacturer
25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173 FR
(33) 02.35.58.14.00
http://www.mylubrizol.com
Emergency Contacts
CHEMTREC
(+1) 703 527 3887
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
Hazard Classifications
GHS Pictograms
GHS07
Hazard Statements
Precautionary Statements
Still copying SDS data manually?Free
You don't have to. NextSDS reads this SDS and adds the information to your library automatically.
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Mineral oil | --- | 20 - 50% | Yes |
| Calcium branched alkyl phenate sulphide (overbased) | --- | 1 - 5% | Yes |
| zinc O,O,O',O'-tetrakis(1,3-dimethylbutyl) bis(phosphorodithioate) EC: 218-679-9 | --- | 1 - 3% | Yes |
| Butanedioic acid, 2,3-dihydroxy-, mixed C12-16-alkyl and C13-rich C11-14-isoalkyl diesters, (2R,3R)-rel- EC: 482-100-8 | --- | 1 - 3% | Yes |
| Reaction products of Benzeneamine, N-phenyl- with nonene (branched) EC: 253-249-4 | --- | 1 - 5% | Yes |
| Phenol, dodecyl-, branched EC: 310-154-3 | --- | 0.01 - 0.25% | Yes |
First Aid Measures
Emergency procedures for chemical exposure incidents
Remove exposed person to fresh air if adverse effects are observed.
Take off contaminated clothing and wash before re-use. Wash with soap and water. Launder contaminated clothing before reuse.
Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
Rinse mouth.
Immediate Medical Attention
If eye irritation persists: Get medical advice/attention. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur (ingestion).
Medical Treatment
Treat symptomatically.
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.
Do not use water jet as an extinguisher, as this will spread the fire.
No unusual fire or explosion hazards noted.
No data available.
Firefighter Protection
Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
Personal Protective Equipment must be worn, see Personal Protection Section for PPE recommendations.
Dike far ahead of larger spill for later recovery and disposal.
Avoid release to the environment. Prevent further leakage or spillage if safe to do so.
Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.
Materials: inert material
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
Avoid contact with eyes. Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Avoid environmental contamination. Keep container closed when not in use.
Keep container closed when not in use.
Observe good industrial hygiene practices. Wash hands thoroughly after handling.
Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
No special requirements under ordinary conditions of use and with adequate ventilation. Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. Supplementary local exhaust ventilation, closed systems, or respiratory and eye protection may be needed in special circumstances, such as poorly ventilated spaces, heating, evaporation of liquids from large surfaces, spraying of mists, mechanical generation of dusts, drying of solids, etc.
Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. The correct choice of protective gloves depends upon the chemicals being handled, and the conditions of work and use. Most gloves provide protection for only a limited time before they must be discarded and replaced. Gloves should be chosen in consultation with the supplier / manufacturer and taking account of a full assessment of the working conditions. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks involving thermal hazards, the standards set out in EN 407 should be considered. Breakthrough time: For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. Glove thickness: For general applications, we recommend gloves with a thickness typically greater than 0.35 mm.
Safety glasses. If potential for splash or mist exists, wear chemical goggles or faceshield. Eye protection should meet the standards set out in EN 166.
Use disposable dust/mist mask if the recommended exposure limit is exceeded. A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Under normal use conditions, respirator is not usually required. Use appropriate respiratory protection if exposure to dust particles, mist or vapors is likely. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment.
Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water.
No data available. See section 6 for details.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
Material is stable under normal conditions.
No data available.
Will not occur.
Do not expose to excessive heat, ignition sources, or oxidizing materials.
Strong mineral acids and strong oxidizing agents. Halogens and halogenated compounds. Strong acids. Strong oxidizing agents. Strong bases. Strong oxidizing agents.
Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, nitrogen oxides, and other products of incomplete combustion.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.1 Ecotoxicity
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.2 Persistence and Degradability
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.3 Bioaccumulative potential
12.4 Mobility:
12.5 Results of PBT and vPvB assessment
12.6 Endocrine Disruption:
No data available.
12.7 Other adverse effects
The product contains an alkylated phenol impurity that is highly toxic to aquatic organisms; however, testing of the calcium phenate component indicates long-lasting harmful effects (Aquatic Chronic 4), suggesting the impurity classification should not be used for the product.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
Treatment, storage, transportation, and disposal must be in accordance with applicable Federal, State/Provincial, and Local regulations.
Dispose of packaging or containers in accordance with local, regional, national and international regulations.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
Regulatory Information
Chemical regulations, safety assessments, and compliance status
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for 605100 R11634A?
The signal word is warning.
What is the physical form of 605100 R11634A?
605100 R11634A is a liquid with brown color. It has mild odor.
What is 605100 R11634A used for?
Heavy Duty Diesel
What are the hazard statements for 605100 R11634A?
This substance has 2 hazard statements:
- H319: Causes serious eye irritation.
- H412: Harmful to aquatic life with long lasting effects.