01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
606713 R14046A

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Passenger Car Oils

Uses advised against

None identified.

Manufacturers & Suppliers

LUBRIZOL FRANCE logo

LUBRIZOL FRANCE

25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173 FR

(33) 02.35.58.14.00

www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

Emergency Contact

09.75.18.14.07

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Eye Irrit. Cat. 2 H319
Skin Sens. Cat. 1 H317
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H317 May cause an allergic skin reaction.
H319 Causes serious eye irritation.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P261 Avoid breathing dust/fume/gas/mist/vapors/spray.
P264 Wash face, hands and any exposed skin thoroughly after handling.
P273 Avoid release to the environment.
P280 Wear protective gloves/protective clothing/eye protection/face protection.
P501 Dispose of contents/ container to an approved facility in accordance with local, regional, national and international regulations.
IF ON SKIN: Wash with plenty of water.
If skin irritation or rash occurs: Get medical advice/attention.
Take off contaminated clothing and wash it before reuse.
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
If eye irritation persists: Get medical advice/attention.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

The mineral oil contained may be described by one or more of the following: EC No. 265-157-1, Registration No. 01-2119484627-25, Distillates (petroleum), hydrotreated heavy paraffinic; EC No. 265-169-7, Registration No. 01-2119471299-27, Distillates (petroleum), solvent-dewaxed heavy paraffinic; EC No. 265-158-7, Registration No. 01-2119487077-29, Distillates (petroleum), hydrotreated light paraffinic; EC No. 265-159-2, Registration No. 01-2119480132-48, Distillates (petroleum), solvent-dewaxed light paraffinic.

Chemical Name CAS Number Concentration Hazardous
N/A --- 20 - 50% Yes
N/A --- 5 - 10% Yes
N/A --- 1 - 5% Yes
N/A --- 1 - 5% Yes
N/A --- 0.25 - 1% Yes

Notes

600, 700 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove exposed person to fresh air if adverse effects are observed.

Skin contact

Take off contaminated clothing and wash before re-use. Wash skin thoroughly with soap and water. Wash with soap and water. If skin irritation or rash occurs: Get medical attention. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.

Eye contact

Rinse cautiously with water for several minutes. Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical advice/attention.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Immediate Medical Attention

If irritation occurs, get medical assistance. If eye irritation persists: Get medical advice/attention. If skin irritation or rash occurs: Get medical attention. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.

Unsuitable media

Do not use water jet as an extinguisher, as this will spread the fire.

Specific hazards

A solid stream of water will spread the burning material. Material creates a special hazard because it floats on water. See section 10 for additional information.

Instructions

No data available.

Firefighter Protection

Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep unauthorized personnel away.

Large spill

Dike far ahead of larger spill for later recovery and disposal.

Environmental

Avoid release to the environment. Do not contaminate water sources or sewer. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Avoid breathing dust/fume/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Avoid contact with skin. Avoid contact with eyes. Observe good industrial hygiene practices. Provide adequate ventilation. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Launder contaminated clothing before reuse. Avoid environmental contamination. Keep container closed when not in use and use with adequate ventilation. In case of spills, beware of slippery floors and surfaces. Use grounding and bonding connection when transferring material. Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.

Storage

Store away from incompatible materials. Odorous and toxic fumes may form from the decomposition of this product if stored at temperatures in excess of 113 deg F (45 deg C) for extended periods of time or if heat sources in excess of 250 deg F (121 deg C) are used.

Hygiene

Observe good industrial hygiene practices. Wash hands thoroughly after handling. Contaminated work clothing should not be allowed out of the workplace. Launder contaminated clothing before reuse.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No special requirements under ordinary conditions of use and with adequate ventilation. Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. Because specific work environments and material handling practices vary, safety procedures should be specific for each intended application. The correct choice of protective gloves depends upon the chemicals being handled, and the conditions of work and use. Most gloves provide protection for only a limited time before they must be discarded and replaced (even the best chemically resistant gloves will break down after repeated chemical exposures). Gloves should be chosen in consultation with the supplier / manufacturer and taking account of a full assessment of the working conditions. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks involving thermal hazards, the standards set out in EN 407 should be considered. Breakthrough time data are generated by glove manufacturers under laboratory test conditions and represent how long a glove can be expected to provide effective permeation resistance. It is important when following breakthrough time recommendations that actual workplace conditions are taken into account. Always consult with your glove supplier for up-to-date technical information on breakthrough times for the recommended glove type. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or > 480 minutes if suitable gloves can be obtained. If suitable gloves are not available to offer that level of protection, gloves with shorter breakthrough times may be acceptable as long as appropriate glove maintenance and replacement regimes are determined and adhered to. For short-term, transient exposures and splash protection, gloves with shorter breakthrough times may commonly be used. Therefore, appropriate maintenance and replacement regimes must be determined and rigorously followed. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. It is important to note that glove thickness is not the only predictor of glove resistance to a specific chemical, as the permeation efficiency of the glove will be dependent on the exact composition of the glove material. Therefore, glove selection should also be based on consideration of the task requirements and knowledge of breakthrough times. Glove thickness may also vary depending on the glove manufacturer, the glove type and the glove model. Therefore, the manufacturers' technical data should always be taken into account to ensure selection of the most appropriate glove for the task. Note: Depending on the activity being conducted, gloves of varying thickness may be required for specific tasks. For example: Thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. However, these gloves are only likely to give short duration protection and would normally be just for single use applications, before being disposed of. Thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential.

Eyes

Wear tight-fitting goggles or face shield. Safety glasses. If potential for splash or mist exists, wear chemical goggles or faceshield. Eye protection should meet the standards set out in EN 166.

Respiratory

A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Use respirator with an organic vapor and dust/mist cartridge if the recommended exposure limit is exceeded. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Use disposable dust/mist mask if the recommended exposure limit is exceeded. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions. Please refer to the relevant EN standards for the RPE selected.

Skin/Body

Wear apron or protective clothing in case of contact. Do not wear rings, watches or similar apparel that could entrap the material. In case of skin contact, wash hands and arms with soap and water. Avoid contact with skin.

Environmental

No data available. See section 6 for details.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Density
---
Solidification Point
---
Bulk Density
---
Flammability
No data available.
Melting Point
---
Flash Point
169 °C
Physical State
liquid
Properties Status
---
Crystallisation Point
---
Relative Evaporation Rate
---
Odor
Characteristic
Evaporation Rate
No data available.
Metal Corrosion
---
Solubility
No data available.
Physical State Data
liquid
Dynamic Viscosity
---
Vapor Pressure
No data available.
Odor Threshold
No data available.
Lower Explosive Limit
No data available.
Colour Intensity
---
Boiling Point
No data available.
State Under Standard Conditions
---
Form
liquid
Upper Explosive Limit
No data available.
Solubility In Fat
---
Auto Ignition Temperature
No data available.
Appearance
---
Decomposition Temperature
No data available.
Molecular Weight
---
Partition Coefficient
No data available.
Cloud Point
---
Vapor Density
---
Ph
Not applicable
Freezing Point
No data available.
Voc Content
No data available.
Colour
Dark amber
Explosive Limits
---
Relative Density
0.943 - 0.983 (15.6 °C)
Kinematic Viscosity
4100 mm2/s (40 °C); 205 mm2/s (100 °C)
Solubility In Water
Insoluble in water
Softening Point
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

No data available.

Hazardous reactions

Will not occur.

Avoid

Do not expose to excessive heat, ignition sources, or oxidizing materials.

Incompatible

Strong mineral acids and strong oxidizing agents.

Decomposition

Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, nitrogen oxides, sulfur oxides, mercaptans, sulfides, including hydrogen sulfide and other products of incomplete combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 606713 R14046A?

The signal word is warning.

What is the physical form of 606713 R14046A?

606713 R14046A is a liquid with dark amber color. It has characteristic odor.

What is the solubility of 606713 R14046A?

No data available.

What is 606713 R14046A used for?

Passenger Car Oils

What are the hazard statements for 606713 R14046A?

This substance has 4 hazard statements:

  • H315: Causes skin irritation.
  • H317: May cause an allergic skin reaction.
  • H319: Causes serious eye irritation.
  • H412: Harmful to aquatic life with long lasting effects.

Compliance Scanner

Scan your compliance