NextSDS Logo
an

anhydrous

DANGER SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
anhydrous
Product Code
11860
Chemical Name
Cadmium chloride, anhydrous

Regulatory Identifiers

CAS Number

Chemical Abstracts Service registry number - unique identifier for chemical substances

EC Number

European Community number - used for regulatory compliance in EU/EEA

Uses Information

Identified Uses
SU24 Scientific research and development

Overview

anhydrous (CAS: 10108-64-2 ) commonly used su24 scientific research and development.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Acute Tox. Category 3 H301
Acute Tox. Category 2 H330
Muta. Category 1B H340
Carc. Category 1B H350
Repr. Category 1B H360
STOT RE Category 1 H372

GHS Hazard Pictograms & Safety Symbols

GHS06 GHS Hazard Pictogram: Acute toxicity hazard - Poisonous materials that can cause death or serious harm

GHS06

GHS08 GHS Hazard Pictogram: Serious health hazard - Carcinogenic, mutagenic, or toxic to organs

GHS08

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H301: Toxic if swallowed.
  • H330: Fatal if inhaled.
  • H340: May cause genetic defects.
  • H350: May cause cancer.
  • H360: May damage fertility or the unborn child.
  • H372: Causes damage to the lung, the kidneys, the liver, the heart, the digestive system, the blood, the brain, the endocrine system and the musculoskeletal through prolonged or repeated exposure. Route of exposure: Oral, Inhalative.

Precautionary Statements

  • P260: Do not breathe dust/fume/gas/mist/vapours/spray.
  • P284: [In case of inadequate ventilation] wear respiratory protection.
  • P301+P310: IF SWALLOWED: Immediately call a POISON CENTER/ doctor/ ...
  • P320: Specific treatment is urgent (see on this label).
  • P405: Store locked up.
  • P501: Dispose of contents/container in accordance with local/regional/national/international regulations.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc. company logo - Safety Data Sheet supplier organization

Alfa Aesar Thermo Fisher Scientific Chemicals, Inc.

manufacturer

๐Ÿ“

30 Bond Street, Ward Hill, MA 01835-8099

๐ŸŒ

US

๐Ÿ“ž

800-343-0660

๐Ÿ“ 

800-322-4757

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

(800) 343-0660

๐Ÿ•’

During normal business hours (Monday-Friday, 8am-7pm EST)

Carechem 24

๐Ÿ“ž

(866) 928-0789

๐Ÿ•’

After normal business hours

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Substances

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Cadmium chloride, anhydrous
EC: 233-296-7
10108-64-2 Not specified โœ“ Non-hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air. If required, provide artificial respiration. Keep patient warm. Seek immediate medical advice.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly. Seek immediate medical advice.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; immediately call for medical help.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Not available
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
White
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Various forms (powder/flake/crystalline/beads, etc.)
๐Ÿ‘ƒ Odor
Odorless
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
Not applicable.
๐ŸงŠ Melting Point
568 โ„ƒ (1054 ยฐF)
Critical Property
๐Ÿ’จ Boiling Point
960 โ„ƒ (1760 ยฐF)
Critical Property
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not applicable.
๐Ÿ’จ Vapor Pressure
0.0000013 hPa
๐Ÿ“Š Vapor Density
Not applicable.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
4.047 g/cm3 (33.772 lbs/gal)
Critical Property
๐Ÿ”ฅ Flammability
Not determined.
๐Ÿ“Š Upper Explosive Limit
Not determined
๐Ÿ“Š Lower Explosive Limit
Not determined
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not determined.
๐Ÿ“Š Decomposition Temperature
Not determined
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Soluble
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not applicable.
๐Ÿ“Š Kinematic Viscosity
Not applicable.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Properly operating chemical fume hood designed for hazardous chemicals and having an average face velocity of at least 100 feet per minute.

๐Ÿงค Hand Protection

Impervious gloves. Check protective gloves prior to each use for their proper condition. The selection of suitable gloves not only depends on the material, but also on quality. Quality will vary from manufacturer to manufacturer. Material of gloves Butyl rubber, BR. Penetration time of glove material (in minutes) Not determined.

๐Ÿ‘๏ธ Eye Protection

Safety glasses

๐Ÿ˜ท Respiratory Protection

Use self-contained respiratory protective device in emergency situations. Recommended filter device for short term use: Use a respirator with type P100 (USA) or P3 (EN 143) cartridges as a backup to engineering controls. Risk assessment should be performed to determine if air-purifying respirators are appropriate. 'Only use equipment tested and approved under appropriate government standards.

๐Ÿฆบ Skin/Body Protection

Protective work clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN2570

๐Ÿ“ฆ Proper Shipping Name

Cadmium compounds (Cadmium chloride, ultra dry)

โš ๏ธ Transport Hazard Class

6.1

๐Ÿ“‹ Packing Group

III

๐Ÿš› ADR Transport Precautions

Warning: Toxic substances

๐Ÿšข IMDG Maritime Transport Precautions

Warning: Toxic substances

โœˆ๏ธ IATA Air Transport Precautions

Warning: Toxic substances

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for anhydrous?

The signal word for this substance is "danger".

What is anhydrous used for?

SU24 Scientific research and development

What are the hazard statements for anhydrous?

This substance has 6 hazard statements: H301: Toxic if swallowed. H330: Fatal if inhaled. H340: May cause genetic defects. H350: May cause cancer. H360: May damage fertility or the unborn child. H372: Causes damage to the lung, the kidneys, the liver, the heart, the digestive system, the blood, the brain, the endocrine system and the musculoskeletal through prolonged or repeated exposure. Route of exposure: Oral, Inhalative.

What is the melting point of anhydrous?

The melting point is 568 โ„ƒ (1054 ยฐF) and the boiling point is 960 โ„ƒ (1760 ยฐF).