Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Temp - Bond Base & Accelerator is a amber paste substance commonly used dental product: temporary cement.
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
Hazard Classifications
GHS Hazard Pictograms & Safety Symbols
GHS07
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
- H317: May cause an allergic skin reaction.
- H319: Causes serious eye irritation.
Precautionary Statements
- P261: Avoid breathing dust.
- P264: Wash thoroughly after handling.
- P272: Contaminated work clothing should not be allowed out of the workplace.
- P280: Wear protective gloves and eye protection.
- P302+P352: IF ON SKIN: Wash with plenty of soap and water.
- P333+P313: If skin irritation or rash occurs: Get medical attention.
- P363: Wash contaminated clothing before reuse.
- P305+P351+P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
- P337+P313: If eye irritation persists: Get medical attention.
- P501: Dispose of contents and container in accordance with local and national regulations.
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Kerr Corporation
manufacturer
1717 W. Collins Ave., Orange, CA 92867-5422, U.S.A.
US
Kerr Australia Pty Limited
national supplier
Unit 6, 12 Mars Road, Lane Cove West, NSW 2066, Australia
AU
1 800 643 603
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
131126
AU
24 hours
CHEMTREC
1-800-424-9300
US
Chemical Emergency Phone Number (Chemical Spills, Leaks, Fire, Exposure or Accident only)
CHEMTREC
1-703-527-3887
US
Chemical Emergency Phone Number (Chemical Spills, Leaks, Fire, Exposure or Accident only)
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Eugenol | 97-53-0 | 30-60% | โ Non-hazardous |
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Remove victim to fresh air. If breathing is difficult or irritation persists, get medical attention.
๐๏ธ Skin Contact
Remove contaminated clothing and shoes. Flush skin thoroughly with water for several minutes. Get medical attention if irritation or rash occurs. Launder clothing before re-use.
Symptoms:
May cause skin sensitization.
๐๏ธ Eye Contact
Rinse thoroughly with water. Get medical attention if irritation occurs and persists.
Symptoms:
May cause moderate eye irritation.
๐ฝ๏ธ Ingestion/Swallowing
If conscious, rinse mouth with water. Do not induce vomiting unless directed by medical personnel. Never give anything by mouth to an unconscious person. Get medical attention.
๐จ Immediate Medical Attention Required
Immediate medical attention is not required.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
โ Suitable Extinguishing Media
Use any media appropriate for the surrounding fire.
โ ๏ธ Specific Fire Hazards
Combustion may produce carbon oxides.
๐ฅ Fire Fighting Instructions
Cool fire exposed containers with water.
๐ก๏ธ Firefighter Protection Equipment
Firefighters should wear positive pressure self-contained breathing apparatus and full protective clothing for fires in areas where chemicals are used or stored.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
๐จ Emergency Procedures
Wear appropriate protective clothing and equipment. Avoid contact with eyes, skin and clothing. Avoid breathing dust from dried product.
๐ง Small Spill Procedures
Wipe up with a paper towel.
๐ Environmental Precautions
Report spill as required by local and federal regulations.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
โ ๏ธ Handling Precautions
โข Avoid contact with eyes, skin and clothing.
โข Wear appropriate eye protection and gloves when handling (see Section 8).
โข Avoid breathing dust from dried product.
โข Use with adequate ventilation.
โข Wash thoroughly with soap and water after handling.
โข Remove and wash contaminated clothing before reuse.
โข Empty containers retain product residues which can be hazardous.
โข Follow all SDS precautions when handling empty containers.
๐ช Storage Conditions
โข Store in a cool, dry, well-ventilated area away from excessive heat.
โข Keep containers tightly closed and sealed until ready for use.
โข Containers that have been opened must be carefully resealed and kept upright to prevent leakage.
โข Do not store in unlabeled containers.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
Use with adequate general or local exhaust ventilation to minimize exposures levels.
๐งค Hand Protection
Impervious gloves are recommended if contact is possible.
๐๏ธ Eye Protection
Chemical safety goggles are recommended if contact is possible.
๐ท Respiratory Protection
None needed under normal use conditions. In operations where exposure levels are exceeded, an approved dust/mist respirator or supplied air respirator should be used. Equipment selection depends on contaminant type and concentration. Select in accordance with applicable regulations and good industrial hygiene practice. For firefighting, use self-contained breathing apparatus.
๐ฆบ Skin/Body Protection
Wear protective clothing as needed to avoid skin contact and contamination of personal clothing.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
โ Chemical Stability
Stable under normal storage and handling conditions.
โ๏ธ Reactivity
The product is not expected to be reactive.
โ ๏ธ Hazardous Reactions
None known.
๐ซ Conditions to Avoid
Avoid excessive heat.
๐งช Incompatible Materials
None known.
๐จ Hazardous Decomposition Products
Thermal decomposition will produce carbon oxides.
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
๐ฑ Toxicity
๐ฑ Persistence and degradability
๐ฑ Bioaccumulative Potential
๐ฑ Mobility in Soil
๐ฑ Other Adverse Effects
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
โป๏ธ Waste Treatment Methods
Dispose of in accordance with Federal and local regulations.
๐๏ธ Product Disposal Recommendations
For unused product, dispose of in accordance with Federal and local regulations. For used product, the waste solution must be characterized by the generator and disposed of in accordance with Federal and local regulations.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
๐ฆ Proper Shipping Name
Not Regulated
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
๐ Regulatory Summary
This product is regulated by the Therapeutic Goods Administration (TGA) and therefore, is exempt from the AICS regulation.
โ Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Temp - Bond Base & Accelerator?
The signal word for this substance is "warning".
What is the solubility of Temp - Bond Base & Accelerator?
Insoluble in water
What is Temp - Bond Base & Accelerator used for?
Dental product: Temporary cement
What are the hazard statements for Temp - Bond Base & Accelerator?
This substance has 2 hazard statements: H317: May cause an allergic skin reaction. H319: Causes serious eye irritation.
What is the melting point of Temp - Bond Base & Accelerator?
The melting point is Not available and the boiling point is Not available.