NextSDS Logo
Safety Data Sheet EN

Gearlube RPC 75W/80W

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Gearlube RPC 75W/80W
Product Code
02.10.32

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, SU21 Consumer uses: Private households / general public / consumers, PC24 Lubricants, greases, release products, PROC2 Use in closed, continuous process with occasional controlled exposure, PROC8a Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at non-dedicated facilities, PROC8b Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at dedicated facilities, PROC20 Heat and pressure transfer fluids in dispersive, professional use but closed systems, PROC9 Transfer of substance or preparation into small containers (dedicated filling line, including weighing), ERC9a Wide dispersive indoor use of substances in closed systems, ERC9b Wide dispersive outdoor use of substances in closed systems, ERC4 Industrial use of processing aids in processes and products, not becoming part of articles, ERC7 Industrial use of substances in closed systems, Lubricating oil

Manufacturers & Suppliers

K

Kroon Oil BV

manufacturer

Dollegoorweg 15, NL-7602 EC ALMELO

+0031-(0)546-818165

Emergency Contacts

Emergency Contact

+31 (0)546 818165

9 AM to 4 PM, Monday to Friday

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Mixture of substances listed below with nonhazardous additions.

Chemical Name CAS Number Concentration Hazardous
Polysulfides, di-tert-Bu EC: 273-103-3 68937-96-2 2.5 - 10% Yes
zinc-tetrakis(1,3-dimethylbutyl) bis(phosphorodithioate) EC: 218-679-9 2215-35-2 1 - 2.5% Yes
Interchangeable low viscosity base oil --- 1 - 2.5% Yes

* Contains one or more of the following CAS-numbers: 64741-88-4, 64741-89-5, 64741-95-3, 64741-96-4, 64741-97-5, 64742-01-4, 64742-52-5, 64742-53-6, 64742-54-7, 64742-55-8, 64742-56-9, 64742-57-0, 64742-58-1, 64742-62-7, 64742-65-0, 64742-71-8, 68037-01-4, 72623-83-7, 72623-85-9, 72623-86-0, 72623-87-1, 74869-22-0, 8042-47-5, 848301-69-9. For the wording of the listed risk phrases refer to section 16.

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of complaints.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

Do not induce vomiting; call for medical help immediately.

Symptoms: If swallowed or in case of vomiting, danger of entering the lungs.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

No further data; see item 7.

Hands

Wear gloves for the protection against chemicals according to EN 374. Oil resistant gloves. Material of gloves Penetration time of glove material: Nitrile rubber, NBR; PVC gloves; Neoprene gloves. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same, but recognise that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time may be acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Goggles recommended during refilling

Respiratory

Not required.

Skin/Body

Protective work clothing

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Melting Point
Undetermined.
Relative Density
---
Colour
Brown
Flash Point
> 110 ℃
Vapor Pressure
---
Vapor Density
---
Physical State Data
liquid
Auto Ignition Temperature
200 ℃
Dynamic Viscosity
---
Properties Status
---
Physical State
Fluid
Evaporation Rate
---
Odor
Characteristic
Explosive Limits
---
Flammability
Not applicable.
Solubility In Fat
---
Upper Explosive Limit
7.0 Vol %
Solubility
Not miscible or difficult to mix.
Density
0.881 g/cm3
Crystallisation Point
---
Boiling Point
Undetermined.
Lower Explosive Limit
0.6 Vol %
Form
Fluid
Voc Content
---
State Under Standard Conditions
---
Metal Corrosion
---
Decomposition Temperature
---
Cloud Point
---
Softening Point
---
Freezing Point
---
Solubility In Water
Not miscible or difficult to mix.
Bulk Density
---
Colour Intensity
---
Kinematic Viscosity
45,1 mm2/s (ASTM D445)
Partition Coefficient
Not determined.
Appearance
Fluid, Brown
Odor Threshold
---
Solidification Point
---
Molecular Weight
---
Relative Evaporation Rate
---
Ph
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Gearlube RPC 75W/80W?

The signal word is no signal word.

What is the physical form of Gearlube RPC 75W/80W?

Gearlube RPC 75W/80W is a fluid appearing as fluid, brown with brown color. It has characteristic odor.

What is the solubility of Gearlube RPC 75W/80W?

Not miscible or difficult to mix.

What is Gearlube RPC 75W/80W used for?

SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, SU21 Consumer uses: Private households / general public / consumers, PC24 Lubricants, greases, release products, PROC2 Use in closed, continuous process with occasional controlled exposure, PROC8a Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at non-dedicated facilities, PROC8b Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at dedicated facilities, PROC20 Heat and pressure transfer fluids in dispersive, professional use but closed systems, PROC9 Transfer of substance or preparation into small containers (dedicated filling line, including weighing), ERC9a Wide dispersive indoor use of substances in closed systems, ERC9b Wide dispersive outdoor use of substances in closed systems, ERC4 Industrial use of processing aids in processes and products, not becoming part of articles, ERC7 Industrial use of substances in closed systems, Lubricating oil

What is the melting point of Gearlube RPC 75W/80W?

The melting point is Undetermined. and the boiling point is Undetermined..