Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Gearlube RPC 75W/80W commonly used su22 professional uses: public domain (administration, education, entertainment, services, craftsmen), su3 industrial uses: uses of substances as such or in preparations at industrial sites, su21 consumer uses: private households / general public / consumers, pc24 lubricants, greases, release products proc2 use in closed, continuous process with occasional controlled exposure proc8a transfer of substance or preparation (charging/discharging) from/to vessels/large containers at non-dedicated facilities proc8b transfer of substance or preparation (charging/discharging) from/to vessels/large containers at dedicated facilities proc20 heat and pressure transfer fluids in dispersive, professional use but closed systems proc9 transfer of substance or preparation into small containers (dedicated filling line, including weighing).
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Kroon Oil BV
manufacturer
Dollegoorweg 15 NL-7602 EC ALMELO
NL
+0031-(0)546-818165
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
+31 (0)546 818165
NL
9 AM to 4 PM, Monday to Friday
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Mixture of substances listed below with nonhazardous additions.
Chemical Components & Hazardous Substances
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| Polysulfides, di-tert-Bu EC: 273-103-3 | 68937-96-2 | 2.5-10% | โ ๏ธ Hazardous |
| zinc-tetrakis(1,3-dimethylbutyl) bis(phosphorodithioate) EC: 218-679-9 | 2215-35-2 | 1-2.5% | โ ๏ธ Hazardous |
| Interchangeable low viscosity base oil | N/A | 1-2.5% | โ ๏ธ Hazardous |
Additional Information
* Contains one or more of the following CAS-numbers: 64741-88-4, 64741-89-5, 64741-95-3, 64741-96-4, 64741-97-5, 64742-01-4, 64742-52-5, 64742-53-6, 64742-54-7, 64742-55-8, 64742-56-9, 64742-57-0, 64742-58-1, 64742-62-7, 64742-65-0, 64742-71-8, 68037-01-4, 72623-83-7, 72623-85-9, 72623-86-0, 72623-87-1, 74869-22-0, 8042-47-5, 848301-69-9. For the wording of the listed risk phrases refer to section 16.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
๐ซ Inhalation Exposure
Supply fresh air; consult doctor in case of complaints.
๐๏ธ Eye Contact
Rinse opened eye for several minutes under running water.
๐ฝ๏ธ Ingestion/Swallowing
Do not induce vomiting; call for medical help immediately.
Symptoms:
If swallowed or in case of vomiting, danger of entering the lungs.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
โ Suitable Extinguishing Media
CO2, dry chemical, or foam. Water can be used to cool and protect exposed material.
โ ๏ธ Specific Fire Hazards
Formation of toxic gases is possible during heating or in case of fire.
๐ก๏ธ Firefighter Protection Equipment
Wear self-contained respiratory protective device. Wear fully protective suit.
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
๐ Environmental Precautions
Do not allow to enter sewers/ surface or ground water.
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
โ ๏ธ Handling Precautions
โข No special measures required.
โข Avoid the formation of oil haze.
๐ช Storage Conditions
โข Store only in the original receptacle.
โข Store in cool, dry conditions in well sealed receptacles.
๐ฅ Fire Prevention Measures
No special measures required.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
๐ญ Engineering Controls
No further data; see item 7.
๐งค Hand Protection
Wear gloves for the protection against chemicals according to EN 374. Oil resistant gloves. Material of gloves Penetration time of glove material: Nitrile rubber, NBR; PVC gloves; Neoprene gloves. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same, but recognise that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time may be acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed.
๐๏ธ Eye Protection
Goggles recommended during refilling
๐ท Respiratory Protection
Not required.
๐ฆบ Skin/Body Protection
Protective work clothing
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
โ๏ธ Reactivity
Reacts with strong oxidising agents.
๐ซ Conditions to Avoid
To avoid thermal decomposition do not overheat.
๐จ Hazardous Decomposition Products
No dangerous decomposition products known.
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
๐ฑ Toxicity
๐ฑ Persistence and degradability
๐ฑ Bioaccumulative potential
๐ฑ Mobility in soil
๐ฑ Results of PBT and vPvB assessment
๐ฑ Endocrine disrupting properties
๐ฑ Other adverse effects
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
โป๏ธ Waste Treatment Methods
Must not be disposed together with household garbage. Do not allow product to reach sewage system.
๐๏ธ Product Disposal Recommendations
Disposal must be made according to official regulations.
๐ท๏ธ Waste Classification Codes
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
๐ Regulatory Summary
Water hazard class 1 (Self-assessment): slightly hazardous for water.
โ Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the solubility of Gearlube RPC 75W/80W?
Not miscible or difficult to mix.
What is Gearlube RPC 75W/80W used for?
SU22 Professional uses: Public domain (administration, education, entertainment, services, craftsmen), SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, SU21 Consumer uses: Private households / general public / consumers, PC24 Lubricants, greases, release products PROC2 Use in closed, continuous process with occasional controlled exposure PROC8a Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at non-dedicated facilities PROC8b Transfer of substance or preparation (charging/discharging) from/to vessels/large containers at dedicated facilities PROC20 Heat and pressure transfer fluids in dispersive, professional use but closed systems PROC9 Transfer of substance or preparation into small containers (dedicated filling line, including weighing)
What is the melting point of Gearlube RPC 75W/80W?
The melting point is Undetermined. Undetermined. .