NextSDS Logo
Sh

Shell Omala S2 GX 150

NO SIGNAL WORD Liquid at room temperature. SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Shell Omala S2 GX 150
Product Code
001F1174

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Gear lubricant.

Overview

Shell Omala S2 GX 150 is a liquid at room temperature. substance commonly used gear lubricant..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word (No signal word)

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Shell Oil Products US

manufacturer

📍

PO Box 4427, Houston TX 77210-4427 USA

🌍

US

📞

(+1) 877-276-7285

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

📞

877-504-9351

🌍

US

💡

Spill Information

Emergency Contact

📞

877-242-7400

🌍

US

💡

Health Information

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Highly refined mineral oils and additives. The highly refined mineral oil contains <3% (w/w) DMSO- extract, according to IP346.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Interchangeable low viscosity base oil (<20,5 cSt @40℃) Not Assigned 90% ⚠️ Hazardous
Alkyl polyamide 68784-17-8 Not specified ⚠️ Hazardous

Composition Notes

contains one or more of the following CAS-numbers: 64742- 53-6, 64742-54-7, 64742-55-8, 64742-56-9, 64742-65-0, 68037-01-4, 72623-86-0, 72623-87-1, 8042-47-5, 848301-69- 9, 68649-12-7, 151006-60-9, 163149-28-8.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

No treatment necessary under normal conditions of use.

🖐️ Skin Contact

Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention.

Symptoms:

persistent irritation

👁️ Eye Contact

Flush eye with copious quantities of water. Remove contact lenses, if present and easy to do. Continue rinsing. If persistent irritation occurs, obtain medical attention.

Symptoms:

persistent irritation

🍽️ Ingestion/Swallowing

In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.

Symptoms:

nausea, vomiting and/or diarrhoea.

🚨 Immediate Medical Attention Required

Treat symptomatically.

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only.

Unsuitable Extinguishing Media

Do not use water in a jet.

⚠️ Specific Fire Hazards

Hazardous combustion products may include: A complex mixture of airborne solid and liquid particulates and gases (smoke). Carbon monoxide may be evolved if incomplete combustion occurs. Unidentified organic and inorganic compounds.

🔥 Fire Fighting Instructions

Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.

🛡️ Firefighter Protection Equipment

Proper protective equipment including chemical resistant gloves are to be worn; chemical resistant suit is indicated if large contact with spilled product is expected. Self-Contained Breathing Apparatus must be worn when approaching a fire in a confined space. Select fire fighter's clothing approved to relevant Standards (e.g. Europe: EN469).

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

🌍 Environmental Precautions

Use appropriate containment to avoid environmental contamination. Prevent from spreading or entering drains, ditches or rivers by using sand, earth, or other appropriate barriers.

🧹 Cleanup Methods

Reclaim liquid directly or in an absorbent. Soak up residue with an absorbent such as clay, sand or other suitable material and dispose of properly.

Cleanup Materials:

absorbent such as clay, sand or other suitable material

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

🧪 Physical State
Liquid at room temperature.
Critical Property
📊 Physical State Data
liquid
📊 State Under Standard Conditions
Not available
👁️ Appearance
Liquid at room temperature.
🎨 Colour
brown
📊 Colour Intensity
Not available
📊 Form
Not available
👃 Odor
Not available
📊 Odor Threshold
Data not available
🧪 Ph
Not applicable
🧊 Melting Point
Data not available
Critical Property
💨 Boiling Point
> 280 °C / 536 °F estimated value(s)
Critical Property
🔥 Flash Point
Typical 240 °C / 464 ºF
Critical Property
📊 Freezing Point
Not available
📊 Softening Point
Not available
📊 Solidification Point
Not available
📊 Cloud Point
Not available
📊 Crystallisation Point
Not available
📊 Relative Evaporation Rate
Not available
💨 Evaporation Rate
Data not available
💨 Vapor Pressure
< 0.5 Pa (20 ℃ / 68 °F)
📊 Vapor Density
Not available
📊 Relative Density
0.897 (15 °C / 59 ºF)
📊 Bulk Density
Not available
⚖️ Density
897 kg/m3 (15.0 ℃ / 59.0 °F) Method: ISO 12185
Critical Property
🔥 Flammability
Data not available
📊 Upper Explosive Limit
Typical 10 %(V)
📊 Lower Explosive Limit
Typical 1 %(V)
📊 Explosive Limits
Not available
📊 Auto Ignition Temperature
> 320 °C / 608 °F
📊 Decomposition Temperature
Data not available
💧 Solubility
Not available
📊 Partition Coefficient
> 6
📊 Solubility In Water
negligible
📊 Solubility In Fat
Not available
📊 Molecular Weight
Not available
📊 Voc Content
Not available
📊 Metal Corrosion
Not available
📊 Dynamic Viscosity
Not available
📊 Kinematic Viscosity
Not available
📊 Properties Status
Not available

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

⚠️ Handling Precautions

• Avoid prolonged or repeated contact with skin.

• Avoid inhaling vapour and/or mists.

• When handling product in drums, safety footwear should be worn and proper handling equipment should be used.

• Properly dispose of any contaminated rags or cleaning materials in order to prevent fires.

🏪 Storage Conditions

• Keep container tightly closed and in a cool, well-ventilated place.

• Use properly labeled and closable containers.

• Store at ambient temperature.

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Select controls based on a risk assessment of local circumstances. Appropriate measures include: Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated. Define procedures for safe handling and maintenance of controls. Educate and train workers in the hazards and control measures relevant to normal activities associated with this product. Ensure appropriate selection, testing and maintenance of equipment used to control exposure, e.g. personal protective equipment, local exhaust ventilation. Drain down system prior to equipment break-in or maintenance. Retain drain downs in sealed storage pending disposal or subsequent recycle.

🧤 Hand Protection

Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves. Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model. It is good practice to wear chemical resistant gloves.

👁️ Eye Protection

If material is handled such that it could be splashed into eyes, protective eyewear is recommended.

😷 Respiratory Protection

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for the combination of organic gases and vapours and particles [Type A/Type P boiling point >65°℃ (149ºF)].

🦺 Skin/Body Protection

Skin protection is not ordinarily required beyond standard work clothes.

🌍 Environmental Exposure Controls

Take appropriate measures to fulfill the requirements of relevant environmental protection legislation. Avoid contamination of the environment by following advice given in Section 6. If necessary, prevent undissolved material from being discharged to waste water. Waste water should be treated in a municipal or industrial waste water treatment plant before discharge to surface water. Local guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing vapour.

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Chemical Stability

Stable.

⚗️ Reactivity

The product does not pose any further reactivity hazards in addition to those listed in the following sub-paragraph.

⚠️ Hazardous Reactions

Reacts with strong oxidising agents.

🚫 Conditions to Avoid

Extremes of temperature and direct sunlight.

🧪 Incompatible Materials

Strong oxidising agents.

💨 Hazardous Decomposition Products

No decomposition if stored and applied as directed.

Ecological Information & Environmental Impact

Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data

🌱 Toxicity to fish (Acute toxicity)

Remarks: LL/EL/IL50 > 100 mg/l Practically non toxic: Based on available data, the classification criteria are not met.

🌱 Toxicity to daphnia and other aquatic invertebrates (Acute toxicity)

Remarks: LL/EL/IL50 > 100 mg/l Practically non toxic: Based on available data, the classification criteria are not met.

🌱 Toxicity to algae (Acute toxicity)

Remarks: LL/EL/IL50 > 100 mg/l Practically non toxic: Based on available data, the classification criteria are not met.

🌱 Biodegradability

Remarks: Not readily biodegradable. Major constituents are inherently biodegradable, but contains components that may persist in the environment.

🌱 Bioaccumulation

Remarks: Contains components with the potential to bioaccumulate.

🌱 Mobility

Remarks: Liquid under most environmental conditions. If it enters soil, it will adsorb to soil particles and will not be mobile. Remarks: Floats on water.

🌱 Additional ecological information

Remarks: Does not have ozone depletion potential, photochemical ozone creation potential or global warming potential. Product is a mixture of non-volatile components, which will not be released to air in any significant quantities under normal conditions of use. Poorly soluble mixture. Causes physical fouling of aquatic organisms. Mineral oil does not cause chronic toxicity to aquatic organisms at concentrations less than 1 mg/l.

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

♻️ Waste Treatment Methods

Recover or recycle if possible. It is the responsibility of the waste generator to determine the toxicity and physical properties of the material generated to determine the proper waste classification and disposal methods in compliance with applicable regulations.

🗂️ Product Disposal Recommendations

Waste product should not be allowed to contaminate soil or ground water, or be disposed of into the environment. Waste, spills or used product is dangerous waste.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Regulatory Information & Compliance

Chemical regulations, safety assessments, and regulatory compliance status

📋 Regulatory Summary

This material does not contain any components with a CERCLA RQ. Shell classifies this material as an 'oil' under the CERCLA Petroleum Exclusion, therefore releases to the environment are not reportable under CERCLA.

Chemical Safety Assessment

No chemical safety assessment has been performed for this substance.

ℹ️ Additional Regulatory Information

This product does not contain any Hazardous Chemicals listed under the U.S. Clean Water Act, Section 311, Table 117.3.

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Shell Omala S2 GX 150?

The signal word for this substance is "no signal word".

What is the physical form of Shell Omala S2 GX 150?

Shell Omala S2 GX 150 is a liquid at room temperature. appearing as liquid at room temperature. with brown color.

What is Shell Omala S2 GX 150 used for?

Gear lubricant.

What is the melting point of Shell Omala S2 GX 150?

The melting point is Data not available and the boiling point is > 280 °C / 536 °F estimated value(s).