Chemical Product Identification & Regulatory Data
Official chemical identifiers, CAS numbers, and regulatory compliance information
Basic Product Information
Regulatory Identifiers
Chemical Abstracts Service registry number - unique identifier for chemical substances
Uses Information
Overview
Shell Omala S2 GX 150 is a liquid at room temperature. substance commonly used gear lubricant..
Manage Your Safety Data Sheets
Organize and access your chemical safety data with ease.
GHS Hazard Classification & Safety Warnings
Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications
Classification Status
Signal Word
GHS Hazard Pictograms & Safety Symbols
GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions
Hazard Statements
Precautionary Statements
Chemical Manufacturers & Supply Chain
Authorized suppliers, manufacturers, and distribution network information
Shell Oil Products US
manufacturer
PO Box 4427, Houston TX 77210-4427 USA
US
(+1) 877-276-7285
24/7 Emergency Response & Poison Control
Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies
Emergency Contact
877-504-9351
US
Spill Information
Emergency Contact
877-242-7400
US
Health Information
Chemical Composition & Hazardous Ingredients
Detailed component analysis, concentration ranges, and hazardous substance identification
Product Type
mixtureGeneral Composition
Highly refined mineral oils and additives. The highly refined mineral oil contains <3% (w/w) DMSO- extract, according to IP346.
Chemical Components & Hazardous Substances
Chemical Name | CAS Number | Concentration | Hazardous |
---|---|---|---|
Interchangeable low viscosity base oil (<20,5 cSt @40℃) | Not Assigned | 90% | ⚠️ Hazardous |
Alkyl polyamide | 68784-17-8 | Not specified | ⚠️ Hazardous |
Composition Notes
contains one or more of the following CAS-numbers: 64742- 53-6, 64742-54-7, 64742-55-8, 64742-56-9, 64742-65-0, 68037-01-4, 72623-86-0, 72623-87-1, 8042-47-5, 848301-69- 9, 68649-12-7, 151006-60-9, 163149-28-8.
Emergency First Aid Measures
Critical first aid procedures for chemical exposure incidents and medical emergencies
🫁 Inhalation Exposure
No treatment necessary under normal conditions of use.
🖐️ Skin Contact
Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention.
Symptoms:
persistent irritation
👁️ Eye Contact
Flush eye with copious quantities of water. Remove contact lenses, if present and easy to do. Continue rinsing. If persistent irritation occurs, obtain medical attention.
Symptoms:
persistent irritation
🍽️ Ingestion/Swallowing
In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.
Symptoms:
nausea, vomiting and/or diarrhoea.
🚨 Immediate Medical Attention Required
Treat symptomatically.
Fire Fighting Measures & Emergency Response
Fire suppression methods, extinguishing media, and firefighting safety procedures
✅ Suitable Extinguishing Media
Foam, water spray or fog. Dry chemical powder, carbon dioxide, sand or earth may be used for small fires only.
❌ Unsuitable Extinguishing Media
Do not use water in a jet.
⚠️ Specific Fire Hazards
Hazardous combustion products may include: A complex mixture of airborne solid and liquid particulates and gases (smoke). Carbon monoxide may be evolved if incomplete combustion occurs. Unidentified organic and inorganic compounds.
🔥 Fire Fighting Instructions
Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
🛡️ Firefighter Protection Equipment
Proper protective equipment including chemical resistant gloves are to be worn; chemical resistant suit is indicated if large contact with spilled product is expected. Self-Contained Breathing Apparatus must be worn when approaching a fire in a confined space. Select fire fighter's clothing approved to relevant Standards (e.g. Europe: EN469).
Accidental Release Measures & Spill Response
Emergency spill cleanup procedures, containment methods, and environmental protection
🌍 Environmental Precautions
Use appropriate containment to avoid environmental contamination. Prevent from spreading or entering drains, ditches or rivers by using sand, earth, or other appropriate barriers.
🧹 Cleanup Methods
Reclaim liquid directly or in an absorbent. Soak up residue with an absorbent such as clay, sand or other suitable material and dispose of properly.
Cleanup Materials:
absorbent such as clay, sand or other suitable material
Related Chemical Substances & Alternative Products
Similar chemicals with comparable safety profiles and industrial applications
Technical Specifications & Material Properties
Physical state, chemical properties, melting point, boiling point, and material characteristics
Safe Handling & Storage Procedures
Industrial handling precautions, storage conditions, and workplace safety requirements
⚠️ Handling Precautions
• Avoid prolonged or repeated contact with skin.
• Avoid inhaling vapour and/or mists.
• When handling product in drums, safety footwear should be worn and proper handling equipment should be used.
• Properly dispose of any contaminated rags or cleaning materials in order to prevent fires.
🏪 Storage Conditions
• Keep container tightly closed and in a cool, well-ventilated place.
• Use properly labeled and closable containers.
• Store at ambient temperature.
Exposure Controls & Personal Protective Equipment (PPE)
Occupational exposure limits, engineering controls, and required safety equipment
🏭 Engineering Controls
The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Select controls based on a risk assessment of local circumstances. Appropriate measures include: Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated. Define procedures for safe handling and maintenance of controls. Educate and train workers in the hazards and control measures relevant to normal activities associated with this product. Ensure appropriate selection, testing and maintenance of equipment used to control exposure, e.g. personal protective equipment, local exhaust ventilation. Drain down system prior to equipment break-in or maintenance. Retain drain downs in sealed storage pending disposal or subsequent recycle.
🧤 Hand Protection
Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves. Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model. It is good practice to wear chemical resistant gloves.
👁️ Eye Protection
If material is handled such that it could be splashed into eyes, protective eyewear is recommended.
😷 Respiratory Protection
No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for the combination of organic gases and vapours and particles [Type A/Type P boiling point >65°℃ (149ºF)].
🦺 Skin/Body Protection
Skin protection is not ordinarily required beyond standard work clothes.
🌍 Environmental Exposure Controls
Take appropriate measures to fulfill the requirements of relevant environmental protection legislation. Avoid contamination of the environment by following advice given in Section 6. If necessary, prevent undissolved material from being discharged to waste water. Waste water should be treated in a municipal or industrial waste water treatment plant before discharge to surface water. Local guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing vapour.
Chemical Stability & Reactivity Data
Chemical stability, hazardous reactions, and incompatible materials information
✅ Chemical Stability
Stable.
⚗️ Reactivity
The product does not pose any further reactivity hazards in addition to those listed in the following sub-paragraph.
⚠️ Hazardous Reactions
Reacts with strong oxidising agents.
🚫 Conditions to Avoid
Extremes of temperature and direct sunlight.
🧪 Incompatible Materials
Strong oxidising agents.
💨 Hazardous Decomposition Products
No decomposition if stored and applied as directed.
Ecological Information & Environmental Impact
Environmental toxicity, biodegradation, bioaccumulation, and ecological effects data
🌱 Toxicity to fish (Acute toxicity)
🌱 Toxicity to daphnia and other aquatic invertebrates (Acute toxicity)
🌱 Toxicity to algae (Acute toxicity)
🌱 Biodegradability
🌱 Bioaccumulation
🌱 Mobility
🌱 Additional ecological information
Waste Disposal & Treatment Methods
Waste disposal procedures, treatment methods, and regulatory compliance requirements
♻️ Waste Treatment Methods
Recover or recycle if possible. It is the responsibility of the waste generator to determine the toxicity and physical properties of the material generated to determine the proper waste classification and disposal methods in compliance with applicable regulations.
🗂️ Product Disposal Recommendations
Waste product should not be allowed to contaminate soil or ground water, or be disposed of into the environment. Waste, spills or used product is dangerous waste.
Transportation & Shipping Information
UN numbers, shipping names, transport classes, and regulatory transport requirements
Regulatory Information & Compliance
Chemical regulations, safety assessments, and regulatory compliance status
📋 Regulatory Summary
This material does not contain any components with a CERCLA RQ. Shell classifies this material as an 'oil' under the CERCLA Petroleum Exclusion, therefore releases to the environment are not reportable under CERCLA.
❌ Chemical Safety Assessment
No chemical safety assessment has been performed for this substance.
ℹ️ Additional Regulatory Information
This product does not contain any Hazardous Chemicals listed under the U.S. Clean Water Act, Section 311, Table 117.3.
Chemical Safety FAQ & Common Questions
Most frequently asked questions about safety, handling, storage, and regulatory compliance
What is the hazard signal word for Shell Omala S2 GX 150?
The signal word for this substance is "no signal word".
What is the physical form of Shell Omala S2 GX 150?
Shell Omala S2 GX 150 is a liquid at room temperature. appearing as liquid at room temperature. with brown color.
What is Shell Omala S2 GX 150 used for?
Gear lubricant.
What is the melting point of Shell Omala S2 GX 150?
The melting point is Data not available and the boiling point is > 280 °C / 536 °F estimated value(s).