NextSDS Logo
Safety Data Sheet EN

Shell Gadus S2 V220 2

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report.

Get Free Audit
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Shell Gadus S2 V220 2
Product Code
001D8451

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Automotive and industrial grease.

Manufacturers & Suppliers

V

Viva Energy Australia Pty Ltd

national supplier

720 Bourke Street, Docklands, Victoria 3008, Australia

+61 (0)3 8823 4444

Emergency Contacts

Australia

1800 651 818

POISONS INFORMATION CENTRE

13 11 26

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

GHS Pictograms

Get a free compliance audit

Upload your SDS inventory and get a detailed compliance report

Free Audit
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type Mixture

A lubricating grease containing highly-refined mineral oils and additives. The highly refined mineral oil contains <3% (w/w) DMSOextract, according to IP346. Classification based on DMSO extract content < 3% (Regulation (EC) 1272/2008, Annex VI, Part 3, Note L).

Chemical Name CAS Number Concentration Hazardous
Bismuth Naphthenate 85736-59-0 0.1 - 0.99% Yes
Naphthenic acid 1338-24-5 --- Yes
Zinc naphthenate 12001-85-3 --- Yes
Alkyl thiadiazole 13539-13-4 --- Yes
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

No treatment necessary under normal conditions of use. If symptoms persist, obtain medical advice.

Skin contact

Remove contaminated clothing. Flush exposed area with water and follow by washing with soap if available. If persistent irritation occurs, obtain medical attention. When using high pressure equipment, injection of product under the skin can occur. If high pressure injuries occur, the casualty should be sent immediately to a hospital. Do not wait for symptoms to develop. Obtain medical attention even in the absence of apparent wounds.

Symptoms: Oil acne/folliculitis signs and symptoms may include formation of black pustules and spots on the skin of exposed areas. Local necrosis is evidenced by delayed onset of pain and tissue damage a few hours following injection.

Eye contact

Flush eye with copious quantities of water. Remove contact lenses, if present and easy to do. Continue rinsing. If persistent irritation occurs, obtain medical attention.

Ingestion

In general no treatment is necessary unless large quantities are swallowed, however, get medical advice.

Symptoms: Ingestion may result in nausea, vomiting and/or diarrhoea.

Immediate Medical Attention

If symptoms persist (inhalation), if persistent irritation occurs (skin/eye), if large quantities are swallowed (ingestion), or if high pressure injuries occur, obtain medical advice/attention immediately. For high pressure injuries, the casualty should be sent immediately to a hospital; do not wait for symptoms to develop, and obtain medical attention even in the absence of apparent wounds.

Medical Treatment

Treat symptomatically. High pressure injection injuries require prompt surgical intervention and possibly steroid therapy, to minimise tissue damage and loss of function. Because entry wounds are small and do not reflect the seriousness of the underlying damage, surgical exploration to determine the extent of involvement may be necessary. Prompt surgical decompression, debridement and evacuation of foreign material should be performed under general anaesthetics, and wide exploration is essential.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

The data for this section has not been processed yet.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

The data for this section has not been processed yet.

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

The data for this section has not been processed yet.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The level of protection and types of controls necessary will vary depending upon potential exposure conditions. Select controls based on a risk assessment of local circumstances. Appropriate measures include: Adequate ventilation to control airborne concentrations. Where material is heated, sprayed or mist formed, there is greater potential for airborne concentrations to be generated. Due to the product's semi-solid consistency, generation of mists and dusts is unlikely to occur.

Hands

Where hand contact with the product may occur the use of gloves approved to relevant standards (e.g. Europe: EN374, US: F739) made from the following materials may provide suitable chemical protection. PVC, neoprene or nitrile rubber gloves Suitability and durability of a glove is dependent on usage, e.g. frequency and duration of contact, chemical resistance of glove material, dexterity. Always seek advice from glove suppliers. Contaminated gloves should be replaced. Personal hygiene is a key element of effective hand care. Gloves must only be worn on clean hands. After using gloves, hands should be washed and dried thoroughly. Application of a non-perfumed moisturizer is recommended. For continuous contact we recommend gloves with breakthrough time of more than 240 minutes with preference for > 480 minutes where suitable gloves can be identified. For short-term/splash protection we recommend the same but recognize that suitable gloves offering this level of protection may not be available and in this case a lower breakthrough time maybe acceptable so long as appropriate maintenance and replacement regimes are followed. Glove thickness is not a good predictor of glove resistance to a chemical as it is dependent on the exact composition of the glove material. Glove thickness should be typically greater than 0.35 mm depending on the glove make and model.

Eyes

If material is handled such that it could be splashed into eyes, protective eyewear is recommended.

Respiratory

No respiratory protection is ordinarily required under normal conditions of use. In accordance with good industrial hygiene practices, precautions should be taken to avoid breathing of material. If engineering controls do not maintain airborne concentrations to a level which is adequate to protect worker health, select respiratory protection equipment suitable for the specific conditions of use and meeting relevant legislation. Check with respiratory protective equipment suppliers. Where air-filtering respirators are suitable, select an appropriate combination of mask and filter. Select a filter suitable for the combination of organic gases and vapours and particles [Type A/Type P boiling point >65C (149F)].

Skin/Body

Skin protection is not ordinarily required beyond standard work clothes. It is good practice to wear chemical resistant gloves.

Environmental

Take appropriate measures to fulfill the requirements of relevant environmental protection legislation. Avoid contamination of the environment by following advice given in Section 6. If necessary, prevent undissolved material from being discharged to waste water. Waste water should be treated in a municipal or industrial waste water treatment plant before discharge to surface water. Local guidelines on emission limits for volatile substances must be observed for the discharge of exhaust air containing vapour.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Melting Point
180 C / 356 F (Dropping point)
Odor Threshold
Data not available
Properties Status
---
Crystallisation Point
---
Auto Ignition Temperature
> 320 °C / 608 °F
Partition Coefficient
log Pow: > 6
Cloud Point
---
Flash Point
Not applicable
Colour Intensity
---
Evaporation Rate
Data not available
Boiling Point
Data not available
Voc Content
---
Density
1,000 kg/m3 (15.0 °C / 59.0 °F)
Odor
Slight hydrocarbon
Solubility In Water
negligible
Upper Explosive Limit
Typical 10 %(V)
Vapor Pressure
< 0.5 Pa (20 °C / 68 °F)
Relative Evaporation Rate
---
Molecular Weight
---
State Under Standard Conditions
---
Explosive Limits
---
Lower Explosive Limit
Typical 1 %(V)
Bulk Density
---
Solubility
---
Colour
brown
Solidification Point
---
Physical State
Semi-solid
Freezing Point
Data not available
Ph
Not applicable
Dynamic Viscosity
Data not available
Kinematic Viscosity
Not applicable
Solubility In Fat
---
Softening Point
---
Relative Density
1.000 (15 °C / 59 °F)
Appearance
Semi-solid at ambient temperature.
Decomposition Temperature
Data not available
Physical State Data
solid
Form
Semi-solid
Flammability
Not classified as flammable but will burn.
Vapor Density
---
Metal Corrosion
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

The data for this section has not been processed yet.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Shell Gadus S2 V220 2?

The signal word is no signal word.

What is the physical form of Shell Gadus S2 V220 2?

Shell Gadus S2 V220 2 is a semi-solid appearing as semi-solid at ambient temperature. with brown color. It has slight hydrocarbon odor.

What is Shell Gadus S2 V220 2 used for?

Automotive and industrial grease.

What is the melting point of Shell Gadus S2 V220 2?

The melting point is 180 C / 356 F (Dropping point) and the boiling point is Data not available.