NextSDS Logo
Me

Metpump IPSX AL

NO SIGNAL WORD Solid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Metpump IPSX AL

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Industrial Furnace Lining Material

Overview

Metpump IPSX AL is a dark grey granular mixture substance commonly used industrial furnace lining material.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

  • P264: Wash thoroughly after handling.
  • P273: Avoid release to the environment.
  • P281: Wear proper personal protective equipment.
  • P402: Store in a dry place.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Magneco/Metrel, Inc.

manufacturer

๐Ÿ“

740 Waukegan Road Deerfield, IL 60015 USA

๐ŸŒ

US

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Magneco/Metrel, Inc.

๐Ÿ“ž

+1 (630) 543-6660

๐ŸŒ

US

Emergency Contact

๐Ÿ“ž

+44 1388 777484

๐ŸŒ

GB

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

The product is a mixture containing Mullite (50-60%), Aluminum Oxide (20-30%), Silicon Dioxide (10-20%), Fumes, Silica (2-4%), and Cristobalite (<0.1%).

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Mullite
EC: 215-113-2
1302-93-8 50-60% โœ“ Non-hazardous
Aluminum Oxide
EC: 215-691-6
1344-28-1 20-30% โœ“ Non-hazardous
Silicon Dioxide
EC: 231-545-4
7631-86-9 10-20% โœ“ Non-hazardous
Fumes, Silica
EC: 273-761-1
69012-64-2 2-4% โœ“ Non-hazardous
Cristobalite
EC: 238-455-4
14464-46-1 0.1% โœ“ Non-hazardous

Composition Notes

The cristobalite and silicon dioxide are chemically combined within the base aggregate. The cristobalite is not present as free crystalline silica.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Remove person to fresh air. If necessary, use artificial respiration to support vital functions.

Symptoms:

respiratory irritant.

๐Ÿ–๏ธ Skin Contact

Wash thoroughly with soap and water. Remove exposed or contaminated clothing, taking care not to contaminate eyes.

Symptoms:

skin irritant

๐Ÿ‘๏ธ Eye Contact

Immediately flush eyes with copious amounts of water continuously for a minimum of 15 minutes.

Symptoms:

Eye irritant

๐Ÿฝ๏ธ Ingestion/Swallowing

DO NOT attempt to induce vomiting. Have the individual rinse mouth with water thoroughly. NEVER give anything to an unconscious person. Call a physician or your local Poison Control Center and immediately have the person transported to a medical facility.

๐Ÿšจ Immediate Medical Attention Required

Seek immediate medical attention if adverse effect occurs. For ingestion, call a physician or your local Poison Control Center and immediately have the person transported to a medical facility.

Medical Treatment

Treat symptomatically.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Solid
Critical Property
๐Ÿ“Š Physical State Data
solid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Dark grey granular mixture
๐ŸŽจ Colour
Dark grey
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Solid
๐Ÿ‘ƒ Odor
Not available
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
ND
๐ŸงŠ Melting Point
>3000F >1650C
Critical Property
๐Ÿ’จ Boiling Point
>3000F >1650C
Critical Property
๐Ÿ”ฅ Flash Point
Not available
๐Ÿ“Š Freezing Point
ND
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
ND
๐Ÿ’จ Vapor Pressure
ND
๐Ÿ“Š Vapor Density
ND
๐Ÿ“Š Relative Density
Not available
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
ND
Critical Property
๐Ÿ”ฅ Flammability
Non-flammable
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
ND
๐Ÿ“Š Decomposition Temperature
ND
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
ND
๐Ÿ“Š Solubility In Water
Negligible
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Ventilation must be adequate to maintain the ambient workplace atmosphere below the exposure limit(s) outlined in the SDS. When engineering controls are not feasible, or while they are being implemented, appropriate respiratory protection must be used. Exposure limits vary between Countries and Local jurisdictions; check which exposure limits apply.

๐Ÿงค Hand Protection

Use abrasive resistant gloves.

๐Ÿ‘๏ธ Eye Protection

Splash goggles or safety glasses with side shields should be worn.

๐Ÿ˜ท Respiratory Protection

If respiratory protection is needed, use a dust mask/respirator certified to NIOSH, ANSI (Z88.2), OSHA (29 CFR 1910.134), MSHA (30 CFR Parts 56 and 57), EN 149, AS 1715, Canadian CSA Standard Z94.4-93, European (E.U.), or individual country standards.

๐Ÿฆบ Skin/Body Protection

Feet: Use approved safety footwear. Body: Use suitable protective clothing.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Metpump IPSX AL?

The signal word for this substance is "no signal word".

What is the physical form of Metpump IPSX AL?

Metpump IPSX AL is a solid appearing as dark grey granular mixture with dark grey color.

What is Metpump IPSX AL used for?

Industrial Furnace Lining Material

What is the melting point of Metpump IPSX AL?

The melting point is >3000F >1650C and the boiling point is >3000F >1650C.