NextSDS Logo
Safety Data Sheet EN

IR Medium

How compliant is your chemical safety?

Free 2-minute compliance assessment

Check Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
IR Medium
Product Code
DISPEX N40 RM.7049

Regulatory Identifiers

CAS Number
N/A

Identified Uses

SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, PC9a Coatings and paints, thinners, paint removers, Rheology additive

Manufacturers & Suppliers

F

Fenzi AGT Netherlands B.V.

manufacturer

Fregatweg 38 6222 NZ Maastricht, The Netherlands

+31 43 3525400

Emergency Contacts

Emergency Contact

+31 43 3525408

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified no signal word

Hazard Classifications

Not Classified

GHS Pictograms

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Solution of resins and additives in a mixture of solvents

For the wording of the listed hazard phrases refer to section 16.

Notes

Hazardous components: Void

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Supply fresh air; consult doctor in case of symptoms.

Eye contact

Rinse opened eye for several minutes under running water.

Ingestion

In case of persistent symptoms consult doctor.

Immediate Medical Attention

No further relevant information available.

Medical Treatment

No further relevant information available.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, extinguishing powder or water spray. Fight larger fires with water jet or alcohol-resistant foam. CO2, extinguishing powder or water spray. Fight larger fire with alcohol-resistant foam.

Unsuitable media

Water with a full water jet.

Specific hazards

No further relevant information available.

Firefighter Protection

Wear self-contained breathing apparatus.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Not required.

Environmental

Do not allow product to reach sewage system or water bodies.

Cleanup methods

Absorb with liquid-binding material

Materials: liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).

Related Substances

Similar chemicals with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

No special measurement required

Storage

None.

Fire prevention

No special measures required.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

The application of this product requires well exhausted firing kilns and efficient ventilation of working areas.

Hands

Use gloves of stable material (e.g. Nitrile) - if necessary tricoted to improve the wearability. Material of gloves: Nitrile rubber, NBR. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation of several substances, the resistance of the glove material can not be calculated in advance and has therefore to be checked prior to the application. Penetration time of glove material: The exact breakthrough time has to be found out by the manufacturer of the protective gloves and has to be observed.

Eyes

Safety glasses recommended during refilling.

Respiratory

Not required.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Physical State
---
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
---
Colour
According to product specification
Colour Intensity
---
Form
Oily
Odor
Characteristic
Odor Threshold
Not determined.
Ph
7.5
Melting Point
Not determined
Boiling Point
100 °C
Flash Point
Not applicable
Freezing Point
Not determined
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
Not determined.
Vapor Pressure
Not determined.
Vapor Density
Not determined.
Relative Density
Not determined.
Bulk Density
---
Density
1.3 g/cm³
Flammability
Not applicable.
Upper Explosive Limit
Not determined.
Lower Explosive Limit
Not determined.
Explosive Limits
---
Auto Ignition Temperature
Product is not selfigniting.
Decomposition Temperature
Not determined.
Solubility
Partly miscible
Partition Coefficient
Not determined.
Solubility In Water
Partly miscible
Solubility In Fat
---
Molecular Weight
---
Voc Content
0.00 %
Metal Corrosion
Void
Dynamic Viscosity
Not determined.
Kinematic Viscosity
Not determined.
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

No decomposition if used according to specifications.

Hazardous reactions

No dangerous reactions known

Decomposition

No dangerous decomposition products known

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Treatment

Must not be disposed of together with household garbage.

Disposal

Must not be disposed of together with household garbage.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

UN Number
Not regulated
Shipping Name
Not regulated
Transport Class
Not regulated
Packing Group
Not regulated
?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for IR Medium?

The signal word is no signal word.

What is the solubility of IR Medium?

Partly miscible

What is IR Medium used for?

SU3 Industrial uses: Uses of substances as such or in preparations at industrial sites, PC9a Coatings and paints, thinners, paint removers, Rheology additive

What is the melting point of IR Medium?

The melting point is Not determined and the boiling point is 100 °C.

Compliance Scan

Free compliance check