NextSDS Logo
Lu

Lumipulse G NfL CSF IRC

WARNING Fluid SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Lumipulse G NfL CSF IRC
Product Form
Particle solution
Product Code
60528

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Laboratory use. For product use see insert.
Uses Advised Against
Not to be used for any purpose other than those mentioned below.

Overview

Lumipulse G NfL CSF IRC commonly used laboratory use. for product use see insert..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Warning)

Hazard Classifications

Skin Sens. Category 1 H317
Aquatic Chronic Category 3 H412

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: May cause an allergic skin reaction.
  • H412: Harmful to aquatic life with long lasting effects.

Precautionary Statements

  • P273: Avoid release to the environment.
  • P280: Wear protective gloves/protective clothing/eye protection/face protection.
  • P302+P352: IF ON SKIN: Wash with plenty of soap and water.
  • P333+P313: If skin irritation or rash occurs: Get medical advice/attention.
  • P362+P364: Take off contaminated clothing and wash it before reuse.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

FUJIREBIO EUROPE N.V.

manufacturer

๐Ÿ“

Technologiepark 6, 9052 Gent, Belgium

๐ŸŒ

BE

๐Ÿ“ž

+32-9-329-13-29

๐Ÿ“ 

+32-9-329-19-11

Fujirebio Europe N.V.

undefined

๐Ÿ“

Technologiepark 6, 9052 Zwijnaarde, Belgium

๐ŸŒ

BE

๐Ÿ“ž

+32-9-329.13.29

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Fujirebio Europe N.V.

๐Ÿ“ž

+32-9-329-13-29

๐ŸŒ

BE

๐Ÿ•’

Mon - Fri 9:00am to 5:30pm

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
saccharose
EC: 200-334-9
57-50-1 Not specified โœ“ Non-hazardous
4-Morpholinopropanesulphonic acid
EC: 214-478-5
1132-61-2 Not specified โš ๏ธ Hazardous
Reaction mass of: 5-chloro-2- methyl-4-isothiazolin-3-one [EC no. 247-500-7] and 2-methyl-2H- isothiazol-3-one [EC no. 220-239- 6] (3:1) 55965-84-9 Not specified โš ๏ธ Hazardous

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Supply fresh air; consult doctor in case of complaints.

๐Ÿ–๏ธ Skin Contact

Immediately wash with water and soap and rinse thoroughly. If skin irritation continues, consult a doctor.

๐Ÿ‘๏ธ Eye Contact

Rinse opened eye for several minutes under running water. If symptoms persist, consult a doctor.

๐Ÿฝ๏ธ Ingestion/Swallowing

Do not induce vomiting; call for medical help immediately.

๐Ÿšจ Immediate Medical Attention Required

No further relevant information available.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Fluid
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
Brownish-red
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Liquid 23-27 , Gel-like solid @2-8
๐Ÿ‘ƒ Odor
Odourless
๐Ÿ“Š Odor Threshold
Not determined.
๐Ÿงช Ph
7.2
๐ŸงŠ Melting Point
Undetermined.
Critical Property
๐Ÿ’จ Boiling Point
Undetermined.
Critical Property
๐Ÿ”ฅ Flash Point
Not applicable.
Critical Property
๐Ÿ“Š Freezing Point
Undetermined.
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Not determined.
๐Ÿ’จ Vapor Pressure
Not determined.
๐Ÿ“Š Vapor Density
Not determined.
๐Ÿ“Š Relative Density
Not determined.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not determined.
Critical Property
๐Ÿ”ฅ Flammability
Product is not flammable.
๐Ÿ“Š Upper Explosive Limit
Not determined.
๐Ÿ“Š Lower Explosive Limit
Not determined.
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Not determined.
๐Ÿ“Š Decomposition Temperature
Not determined.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
Not determined.
๐Ÿ“Š Solubility In Water
Soluble.
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
void
๐Ÿ“Š Dynamic Viscosity
Not determined.
๐Ÿ“Š Kinematic Viscosity
Not determined.
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

No further data; see item 7.

๐Ÿงค Hand Protection

Wear protective gloves in order to be protected against chemical risks according to EN 420 and EN 374. The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. As the product is a preparation consisting of different substances, no specific information can be given about breakthrough times. The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. As protection from splashes gloves made of the following materials are suitable: Nitrile rubber, NBR. Recommended thickness of the material: 0.11 mm

๐Ÿ‘๏ธ Eye Protection

Wear safety glasses in order to protect your eyes against chemical splashes according to EN 166.

๐Ÿ˜ท Respiratory Protection

Not necessary if room is well-ventilated.

๐Ÿฆบ Skin/Body Protection

Wear a laboratory coat for your protection against chemical splashes according to EN 340 and EN 369.

๐ŸŒ Environmental Exposure Controls

Comply with the current local and national environmental regulations.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Lumipulse G NfL CSF IRC?

The signal word for this substance is "warning".

What is the physical form of Lumipulse G NfL CSF IRC?

Lumipulse G NfL CSF IRC is a fluid with brownish-red color. It has odourless odor.

What is Lumipulse G NfL CSF IRC used for?

Laboratory use. For product use see insert.

What are the hazard statements for Lumipulse G NfL CSF IRC?

This substance has 2 hazard statements: H317: May cause an allergic skin reaction. H412: Harmful to aquatic life with long lasting effects.

What is the melting point of Lumipulse G NfL CSF IRC?

The melting point is Undetermined. and the boiling point is Undetermined..