NextSDS Logo
Safety Data Sheet EN

606337 R13093A

Scan your chemical compliance

Free 10-second scan. Upload a document and check compliance instantly.

Scan Now
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
606337 R13093A

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Heavy duty diesel engine oil additive.

Uses advised against

None identified.

Manufacturers & Suppliers

LUBRIZOL FRANCE logo

LUBRIZOL FRANCE

25 QUAI DE FRANCE CS 61062 76173 ROUEN CEDEX, 76173 FR

(33) 02.35.58.14.00

www.mylubrizol.com

Emergency Contacts

CHEMTREC

(+1) 703 527 3887

Emergency Contact

09.75.18.14.07

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified warning

Hazard Classifications

Skin Irrit. Cat. 2 H315
Aquatic Chronic Cat. 3 H412

GHS Pictograms

GHS07 - Health hazard

GHS07

Hazard Statements

H315 Causes skin irritation.
H412 Harmful to aquatic life with long lasting effects.

Precautionary Statements

P264 Wash face, hands and any exposed skin thoroughly after handling.
P273 Avoid release to the environment.
P280 Wear protective gloves/ protective clothing/ eye protection/ face protection.
P302 + P352 IF ON SKIN: Wash with plenty of water.
P362 + P364 Take off contaminated clothing and wash it before reuse.
P501 Dispose of contents/ container to an approved facility in accordance with local, regional, national and international regulations.

Manage your Safety Data Sheets

Organize and access chemical safety data with ease

Manage SDS
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture

Regulation No. 1272/2008. 600, 700 and 900 ECHA List Numbers do not have any legal significance; rather they are purely technical identifiers and are displayed for informational purposes only. The mineral oil contained may be described by one or more of the following: EC No. 265-157-1, Registration No. 01-2119484627-25, Distillates (petroleum), hydrotreated heavy paraffinic; EC No. 265-169-7, Registration No. 01-2119471299-27, Distillates (petroleum), solvent-dewaxed heavy paraffinic; EC No. 265-158-7, Registration No. 01-2119487077-29, Distillates (petroleum), hydrotreated light paraffinic; EC No. 265-159-2, Registration No. 01-2119480132-48, Distillates (petroleum), solvent-dewaxed light paraffinic.

Chemical Name CAS Number Concentration Hazardous
N/A --- 20 - 50% Yes
N/A --- 1 - 10% Yes
N/A --- 6.25 - 10% Yes
N/A --- 1 - 5% Yes
N/A --- 1 - 5% Yes
N/A --- 1 - 5% Yes
N/A --- 0.1 - 1% Yes
N/A --- 0.01 - 0.25% Yes
N/A --- 0.1 - 0.25% Yes
N/A --- 0.1 - 0.25% Yes

EU. REACH Candidate List of Substances of Very High Concern for Authorization (SVHC) Endocrine Disruption-Toxicity Phenol, dodecyl-, branched The substance is considered to have endocrine disrupting properties according to REACH Article 57(f) for human health. Endocrine Disruption-Ecotoxicity Phenol, dodecyl-, branched The substance is considered to have endocrine disrupting properties according to REACH Article 57(f) for the environment.

Notes

The full text for all H-phrases is displayed in section 16. See Section 15 for Regulation (EC) No. 1907/2006 REACH Article 59(1). Candidate List (Substances of Very High Concern (SVHC))

04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove exposed person to fresh air if adverse effects are observed.

Skin contact

Take off contaminated clothing and wash before re-use. Wash skin thoroughly with soap and water. Wash with soap and water. If skin irritation occurs, get medical attention. Get medical attention if symptoms occur. Launder contaminated clothing before reuse.

Eye contact

Flush thoroughly with water. If irritation occurs, get medical assistance. Remove contact lenses, if present and easy to do. Continue rinsing.

Ingestion

Rinse mouth. Get medical attention if symptoms occur.

Immediate Medical Attention

IF exposed or concerned: Get medical advice/attention.

Medical Treatment

Treat symptomatically.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

CO2, Dry chemical or Foam. Water can be used to cool and protect exposed material.

Unsuitable media

Not determined.

Specific hazards

See section 10 for additional information.

Instructions

No data available.

Firefighter Protection

Wear full protective firegear including self-containing breathing apparatus operated in the positive pressure mode with full facepiece, coat, pants, gloves and boots.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep unauthorized personnel away.

Large spill

Dike far ahead of larger spill for later recovery and disposal.

Environmental

Avoid release to the environment. Do not contaminate water sources or sewer. Prevent further leakage or spillage if safe to do so.

Cleanup methods

Pick up free liquid for recycle and/or disposal. Residual liquid can be absorbed on inert material.

Materials: inert material

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep container closed when not in use and use with adequate ventilation. Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material. In case of spills, beware of slippery floors and surfaces. Do not handle until all safety precautions have been read and understood. Obtain special instructions before use. Avoid contact with skin. Observe good industrial hygiene practices. Provide adequate ventilation. Use personal protective equipment as required. Wash hands thoroughly after handling. Launder contaminated clothing before reuse. Avoid environmental contamination.

Storage

Store away from incompatible materials. Odorous and toxic fumes may form from the decomposition of this product. Do not store product at temperature in excess of 45°C (113°F) for extended periods of time, 1 week or more; or, using a heat source, such as steam, at a temperature in excess of 100°C (212°F).

Hygiene

Observe good industrial hygiene practices. Wash hands thoroughly after handling. Launder contaminated clothing before reuse.

Fire prevention

Material can accumulate static charges which may cause an electrical spark (ignition source). Use proper bonding and/or grounding procedures. Use grounding and bonding connection when transferring material.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use material in well ventilated area only. Material should be handled in enclosed vessels and equipment, in which case general (mechanical) room ventilation should be sufficient. Local exhaust ventilation should be used at points where dust, mist, vapors or gases can escape into the room air. Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level.

Hands

Use nitrile or neoprene gloves. Use good industrial hygiene practices. In case of skin contact, wash hands and arms with soap and water. For typical use and handling of chemical substances, gloves should meet the standards set out in EN 374. For applications involving mechanical risks with potential for abrasion or puncture, the standards set out in EN 388 should be considered. For tasks involving thermal hazards, the standards set out in EN 407 should be considered. For continuous contact, we suggest gloves with a minimum breakthrough time of 240 minutes, or >480 minutes if suitable gloves can be obtained. If suitable gloves are not available to offer that level of protection, gloves with shorter breakthrough times may be acceptable as long as appropriate glove maintenance and replacement regimes are determined and adhered to. For short-term, transient exposures and splash protection, gloves with shorter breakthrough times may commonly be used. Therefore, appropriate maintenance and replacement regimes must be determined and rigorously followed. For general applications, we recommend gloves with a thickness typically greater than 0.35 mm. It is important to note that glove thickness is not the only predictor of glove resistance to a specific chemical, as the permeation efficiency of the glove will be dependent on the exact composition of the glove material. Therefore, glove selection should also be based on consideration of the task requirements and knowledge of breakthrough times. Glove thickness may also vary depending on the glove manufacturer, the glove type and the glove model. Therefore, the manufacturers' technical data should always be taken into account to ensure selection of the most appropriate glove for the task. Note: Depending on the activity being conducted, gloves of varying thickness may be required for specific tasks. For example: Thinner gloves (down to 0.1 mm or less) may be required where a high degree of manual dexterity is needed. However, these gloves are only likely to give short duration protection and would normally be just for single use applications, before being disposed of. Thicker gloves (up to 3 mm or more) may be required where there is a mechanical (as well as a chemical) risk i.e. where there is abrasion or puncture potential.

Eyes

Wear tight-fitting goggles or face shield. Eye protection should meet the standards set out in EN 166.

Respiratory

A respiratory protection program compliant with all applicable regulations must be followed whenever workplace conditions require the use of a respirator. Use respirator with an organic vapor and dust/mist cartridge if the recommended exposure limit is exceeded. Use self-contained breathing apparatus for entry into confined space, for other poorly ventilated areas and for large spill clean-up sites. Respiratory Protective Equipment (RPE) is not normally required where there is adequate natural or local exhaust ventilation to control exposure. In case of insufficient ventilation, wear suitable respiratory equipment. The correct choice of respiratory protection depends upon the chemicals being handled, the conditions of work and use, and the condition of the respiratory equipment. Safety procedures should be developed for each intended application. Respiratory protection equipment should therefore be chosen in consultation with the supplier/manufacturer and with a full assessment of the working conditions. Please refer to the relevant EN standards for the RPE selected.

Skin/Body

Wear apron or protective clothing in case of contact. Do not wear rings, watches or similar apparel that could entrap the material. Chemical resistant boots.

Environmental

No data available. See section 6 for details.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Solubility In Fat
---
Solubility In Water
No data available.
Cloud Point
---
Melting Point
---
Relative Evaporation Rate
---
Odor
Mild
Freezing Point
No data available.
Relative Density
0.932 - 0.972 (15.6 °C)
Crystallisation Point
---
Softening Point
---
Vapor Pressure
No data available.
Ph
Not applicable
Odor Threshold
No data available.
Kinematic Viscosity
1305 mm2/s (40 °C); 80 mm2/s (100 °C); 3714 mm2/s (25 °C)
Form
liquid
Physical State Data
liquid
Metal Corrosion
---
Upper Explosive Limit
No data available.
Evaporation Rate
No data available.
Boiling Point
No data available.
Voc Content
No data available.
Explosive Limits
---
Bulk Density
7.93 lb/gal (15.6 °C)
Molecular Weight
---
Lower Explosive Limit
No data available.
Solubility
No data available.
Flash Point
154 °C
Appearance
Dark brown
Flammability
No data available.
Properties Status
---
Colour
Dark brown
Partition Coefficient
No data available.
Physical State
liquid
Auto Ignition Temperature
No data available.
Dynamic Viscosity
---
Solidification Point
---
Density
---
Colour Intensity
---
State Under Standard Conditions
---
Vapor Density
---
Decomposition Temperature
No data available.
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Material is stable under normal conditions.

Reactivity

No data available.

Hazardous reactions

Will not occur.

Avoid

Do not expose to excessive heat, ignition sources, or oxidizing materials.

Incompatible

Strong oxidizing agents. Halogens and halogenated compounds.

Decomposition

Thermal decomposition or combustion may generate smoke, carbon monoxide, carbon dioxide, nitrogen oxides, and other products of incomplete combustion. Diphenylamine and alkenes may also be released.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

The data for this section has not been processed yet.

13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

The data for this section has not been processed yet.

14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

The data for this section has not been processed yet.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for 606337 R13093A?

The signal word is warning.

What is the physical form of 606337 R13093A?

606337 R13093A is a liquid appearing as dark brown with dark brown color. It has mild odor.

What is the solubility of 606337 R13093A?

No data available.

What is 606337 R13093A used for?

Heavy duty diesel engine oil additive.

What are the hazard statements for 606337 R13093A?

This substance has 2 hazard statements:

  • H315: Causes skin irritation.
  • H412: Harmful to aquatic life with long lasting effects.

Compliance Scanner

Scan your compliance