NextSDS Logo
Safety Data Sheet EN

Curos™ Disinfecting Port Protectors

Keep this SDS organized and up to date

Add this SDS to your NextSDS library and keep all its safety information in one place.

Add to my SDS library for free
01

Identification

Product identifiers, regulatory numbers, and supplier information

Product Information

Product Name
Curos™ Disinfecting Port Protectors
Product Code
CM5-200, CFJ1-270, CFJ5-250, CSA1-270, CSA1-270R, CSA5-250, CSV1-270, CSV5-250, 70-2007-8983-5, 70-2007-9016-3, 70-2007-9283-9, 70-2007-9286-2, 70-2007-9287-0, 70-2007-9288-8, 70-2007-9289-6, 70-2007-9385-2, 70-2007-9386-0, 70-2007-9389-4, 70-2011-7308-8, 70-2011-7309-6, 70-2011-7522-4, 70-2011-8775-7, 70-2011-8776-5, 70-2011-8777-3, 70-2011-8782-3, 7100069150, 7100085563, 7100102598, 7100102601, 7100102602, 7100102603, 7100102604, 7100104336, 7100104567, 7100101997, 7100101993, 7100101994, 7100141836, 7100233028, 7100233024, 7100233025, 7100232900

Regulatory Identifiers

CAS Number
N/A

Identified Uses

Port Protector, Industrial use

Manufacturers & Suppliers

3

3M

manufacturer

3M Center, St. Paul, MN 55144-1000, USA

1-888-364-3577

Emergency Contacts

Emergency Contact

1-800-364-3577

24 hours

Emergency Contact

(651) 737-6501

24 hours

02

Hazard Identification

GHS classification, signal word, pictograms, and hazard statements

Classified danger

Hazard Classifications

Flam. Liq. Cat. 2
Eye Irrit. Cat. 2A
STOT SE Cat. 3

GHS Pictograms

GHS02 - Flammable

GHS02

GHS07 - Health hazard

GHS07

Hazard Statements

H225 Highly flammable liquid and vapor.
H319 Causes serious eye irritation.
H336 May cause drowsiness or dizziness.

Precautionary Statements

P210 Keep away from heat/sparks/open flames/hot surfaces. - No smoking.
P235 Keep cool.
P240 Ground/bond container and receiving equipment.
P241 Use explosion-proof electrical/ventilating/lighting equipment.
P242 Use only non-sparking tools.
P243 Take precautionary measures against static discharge.
P261 Avoid breathing dust/fume/gas/mist/vapors/spray.
P264 Wash thoroughly after handling.
P271 Use only outdoors or in a well-ventilated area.
P280 Wear protective gloves and eye/face protection.
P303 + P361 + P353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower.
P304 + P340 IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P312 Call a POISON CENTER or doctor/physician if you feel unwell.
P337 + P313 If eye irritation persists: Get medical advice/attention.
P370 + P378 In case of fire: Use a fire fighting agent suitable for flammable liquids such as dry chemical or carbon dioxide to extinguish.
P403 + P233 Store in a well-ventilated place. Keep container tightly closed.
P405 Store locked up.
P501 Dispose of contents/container in accordance with applicable local/regional/national/international regulations.

Still copying SDS data manually?Free

You don't have to. NextSDS reads this SDS and adds the information to your library automatically.

Let NextSDS do it for me
03

Composition / Information on Ingredients

Chemical components, concentration ranges, and hazardous substance identification

Type mixture
Chemical Name CAS Number Concentration Hazardous
Isopropyl Alcohol 67-63-0 65 - 75% No
Water 7732-18-5 25 - 35% No
04

First Aid Measures

Emergency procedures for chemical exposure incidents

Inhalation

Remove person to fresh air. If you feel unwell, get medical attention.

Skin contact

Immediately wash with soap and water. Remove contaminated clothing and wash before reuse. If signs/symptoms develop, get medical attention.

Eye contact

Immediately flush with large amounts of water. Remove contact lenses if easy to do. Continue rinsing. Get medical attention.

Ingestion

Rinse mouth. If you feel unwell, get medical attention.

05

Firefighting Measures

Extinguishing media, specific hazards, and firefighter protection

Suitable media

Use a fire fighting agent suitable for flammable liquids such as dry chemical or carbon dioxide to extinguish.

Specific hazards

Closed containers exposed to heat from fire may build pressure and explode.

Instructions

Water may not effectively extinguish fire; however, it should be used to keep fire-exposed containers and surfaces cool and prevent explosive rupture.

Firefighter Protection

Wear full protective clothing, including helmet, self-contained, positive pressure or pressure demand breathing apparatus, bunker coat and pants, bands around arms, waist and legs, face mask, and protective covering for exposed areas of the head.

06

Accidental Release Measures

Spill cleanup procedures, containment, and environmental protection

Emergency procedures

Evacuate area. Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Ventilate the area with fresh air.

Large spill

provide mechanical ventilation to disperse or exhaust vapors, in accordance with good industrial hygiene practice.

Environmental

Avoid release to the environment.

Cleanup methods

Collect as much of the spilled material as possible using non-sparking tools. Place in a metal container approved for transportation by appropriate authorities. Clean up residue with water. Seal the container.

—

Related Products

Similar products with comparable safety profiles

07

Handling and Storage

Safe handling precautions, storage conditions, and workplace requirements

Handling

Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Take precautionary measures against static discharge. Avoid breathing dust/fume/gas/mist/vapors/spray. Do not get in eyes, on skin, or on clothing. Do not eat, drink or smoke when using this product. Wash thoroughly after handling. Avoid release to the environment. Avoid contact with oxidizing agents (eg. chlorine, chromic acid etc.) Keep away from reactive metals (eg. Aluminum, zinc etc.) to avoid the formation of hydrogen gas that could create an explosion hazard. Wear low static or properly grounded shoes.

Storage

Store in a well-ventilated place. Keep cool. Keep container tightly closed.

Hygiene

Do not eat, drink or smoke when using this product. Wash thoroughly after handling.

Fire prevention

Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use only non-sparking tools. Take precautionary measures against static discharge. Ground/bond container and receiving equipment if there is potential for static electricity accumulation during transfer.

08

Exposure Controls / PPE

Occupational exposure limits, engineering controls, and protective equipment

Engineering

Use explosion-proof ventilation equipment.

Hands

Gloves made from the following material(s) are recommended: Nitrile Rubber

Eyes

Safety Glasses with side shields, Indirect Vented Goggles

Respiratory

Half facepiece or full facepiece air-purifying respirator suitable for organic vapors

Skin/Body

Select and use gloves and/or protective clothing approved to relevant local standards to prevent skin contact based on the results of an exposure assessment.

09

Physical and Chemical Properties

Appearance, physical state, melting point, boiling point, and material characteristics

Language Code
---
Physical State
Liquid
Physical State Data
liquid
State Under Standard Conditions
---
Appearance
Colorless
Colour
Colorless
Colour Intensity
---
Form
---
Odor
Solvent
Odor Threshold
No Data Available
Ph
No Data Available
Melting Point
No Data Available
Boiling Point
181 °F [Details: for IPA]
Flash Point
64.9 °F [Test Method: Closed Cup] [Details: for IPA]
Freezing Point
---
Softening Point
---
Solidification Point
---
Cloud Point
---
Crystallisation Point
---
Relative Evaporation Rate
---
Evaporation Rate
1.7 [Ref Std: BUOAC=1] [Details: for IPA]
Vapor Pressure
32.4 mmHg [@ 68 °F] [Details: for IPA]
Vapor Density
2.1 [Ref Std: AIR=1] [Details: for IPA]
Relative Density
0.877 [Ref Std: WATER=1] [Details: for IPA]
Bulk Density
---
Density
0.877 g/ml [Details: for IPA]
Flammability
---
Upper Explosive Limit
12.7 % [Details: for IPA]
Lower Explosive Limit
2 % [Details: for IPA]
Explosive Limits
---
Auto Ignition Temperature
750 °F [Details:for IPA]
Decomposition Temperature
No Data Available
Solubility
---
Partition Coefficient
0.05
Solubility In Water
Complete
Solubility In Fat
---
Molecular Weight
Not Applicable
Voc Content
---
Metal Corrosion
---
Dynamic Viscosity
2.2 mPa·s [Details:for IPA]
Kinematic Viscosity
---
Properties Status
---
10

Stability and Reactivity

Chemical stability, hazardous reactions, and incompatible materials

Stability

Stable.

Reactivity

This material may be reactive with certain agents under certain conditions - see the remaining headings in this section.

Hazardous reactions

Hazardous polymerization will not occur.

Avoid

Sparks and/or flames

Incompatible

Reactive metals, Strong acids, Strong oxidizing agents

Decomposition

None known. Refer to section 5.2 for hazardous decomposition products during combustion.

12

Ecological Information

Environmental toxicity, biodegradation, and bioaccumulation data

12.1 Toxicity

Please contact the address or phone number listed on the first page of the SDS for additional ecotoxicological information on this material and/or its components.

12.2 Persistence and degradability

Please contact the address or phone number listed on the first page of the SDS for additional chemical fate information on this material and/or its components.

12.3 Bioaccumulative potential

Please contact the address or phone number listed on the first page of the SDS for additional chemical fate information on this material and/or its components.

12.4 Mobility in soil

Please contact the address or phone number listed on the first page of the SDS for additional chemical fate information on this material and/or its components.

12.5 Results of PBT and vPvB assessment

Please contact the address or phone number listed on the first page of the SDS for additional chemical fate information on this material and/or its components.

12.6 Endocrine disrupting properties

Please contact the address or phone number listed on the first page of the SDS for additional chemical fate information on this material and/or its components.

12.7 Other adverse effects

Please contact the address or phone number listed on the first page of the SDS for additional chemical fate information on this material and/or its components.
13

Disposal Considerations

Waste treatment methods, disposal recommendations, and waste codes

Disposal

Dispose of contents/ container in accordance with the local/regional/national/international regulations.

Waste Codes

D001 Ignitable RCRA
14

Transport Information

UN numbers, shipping names, transport classes, and regulatory requirements

15

Regulatory Information

Chemical regulations, safety assessments, and compliance status

Chemical Safety Assessment Not performed

Contact 3M for more information.

?

Frequently Asked Questions

Common questions about safety, handling, and properties

What is the hazard signal word for Curos™ Disinfecting Port Protectors?

The signal word is danger.

What is the physical form of Curos™ Disinfecting Port Protectors?

Curos™ Disinfecting Port Protectors is a liquid appearing as colorless with colorless color. It has solvent odor.

What is Curos™ Disinfecting Port Protectors used for?

Port Protector, Industrial use

What are the hazard statements for Curos™ Disinfecting Port Protectors?

This substance has 3 hazard statements:

  • H225: Highly flammable liquid and vapor.
  • H319: Causes serious eye irritation.
  • H336: May cause drowsiness or dizziness.

What is the melting point of Curos™ Disinfecting Port Protectors?

The melting point is No Data Available and the boiling point is 181 °F [Details: for IPA].