NextSDS Logo
YA

YACHT VERNIS SATIN INCOLORE

WARNING Liquide. SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
YACHT VERNIS SATIN INCOLORE

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Peinture en phase solvant à usage extérieur.

Overview

YACHT VERNIS SATIN INCOLORE commonly used peinture en phase solvant à usage extérieur..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Flam. Liq. Category 3 H226
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Liquide et vapeurs inflammables.
  • H336: Peut provoquer somnolence ou vertiges.

Precautionary Statements

  • P101: En cas de consultation d'un médecin, garder à disposition le récipient ou l'étiquette.
  • P102: Tenir hors de portée des enfants.
  • P210: Tenir à l'écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d'inflammation. Ne pas fumer.
  • P261: Éviter de respirer les vapeurs.
  • P271: Utiliser seulement en plein air ou dans un endroit bien ventilé.
  • P304 + P312: EN CAS D'INHALATION: Appeler un CENTRE ANTIPOISON ou un médecin en cas de malaise.
  • P403 + P233: Stocker dans un endroit bien ventilé. Maintenir le récipient fermé de manière étanche.
  • P403 + P235: Tenir au frais.
  • P405: Garder sous clef.
  • P501: Eliminer le contenu et le récipient conformément aux réglementations locales, régionales, nationales ou internationales.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Akzo Nobel Paints Belgium NV/SA

manufacturer

Everest Office Park - Leuvensesteenweg 248 B, B 1800 Vilvoorde - Belgium

BE

+32 (0) 2 254 2211

+32 (0) 2 254 2335

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antipoisoncenter/Antigifcentrum/Centre Antipoisons/Antigiftzentrum

+32 (0) 70 245 245

BE

Emergency Contact

+32 2 254 22 11

BE

8.00 - 16.30

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbures, C9-C11, n- alcanes, isoalcanes, cycliques, <2 % aromatiques
EC: 919-857-5
N/A 20-25% Hazardous
Hydrocarbures,C10-C13, n- alcanes,isoalcanes, cycliques,<2%aromatiques
EC: 918-481-9
N/A 10-15% Hazardous
XYLENE; MELANGE ISOMERES O,M,P
EC: 215-535-7
1330-20-7 1% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Transporter la victime à l'extérieur et la maintenir au repos dans une position où elle peut confortablement respirer. Si l'on soupçonne que des fumées sont encore présentes, le sauveteur devra porter un masque adéquat ou un appareil de protection respiratoire autonome. Si elle ne respire pas, en cas de respiration irrégulière ou d'arrêt respiratoire, que le personnel qualifié pratique la respiration artificielle ou administre de l'oxygène. Consulter un médecin. Si nécessaire, appeler un centre antipoison ou un médecin. En cas d'évanouissement, placez la personne en position latérale de sécurité et appelez un médecin immédiatement. Assurez-vous d'une bonne circulation d'air. Détacher tout ce qui pourrait être serré, comme un col, une cravate, une ceinture ou un ceinturon. En cas d'inhalation de produits de décomposition lors d'un incendie, les symptômes peuvent être différés. La personne exposée peut avoir besoin de rester sous surveillance médicale pendant 48 heures.

Symptoms:

Nausées, vomissements, migraine, somnolence/fatigue, étourdissements/vertiges, évanouissement.

Skin Contact

Laver soigneusement la peau au savon et à l'eau ou utiliser un nettoyant cutané reconnu. Retirer les vêtements et les chaussures contaminés. Consulter un médecin si des symptômes se développent. Laver les vêtements avant de les réutiliser. Laver les chaussures à fond avant de les remettre.

Symptoms:

Irritation, sécheresse, gerçure.

Eye Contact

Rincer immédiatement les yeux à grande eau, en soulevant de temps en temps les paupières supérieures et inférieures. Vérifier si la victime porte des verres de contact et dans ce cas, les lui enlever. Continuez de rincer pendant 10 minutes au moins. Consulter un médecin.

Symptoms:

Aucune donnée spécifique.

Ingestion/Swallowing

Rincez la bouche avec de l'eau. Enlever les prothèses dentaires s'il y a lieu. Si une personne a avalé de ce produit et est consciente, lui faire boire de petites quantités d'eau. Si la personne est indisposée, cesser de la faire boire car des vomissements pourraient entraîner un risque supplémentaire. Ne pas faire vomir sauf indication contraire émanant du personnel médical. En cas de vomissement, maintenez la tête vers le bas pour empêcher le passage des vomissures dans les poumons. Consulter un médecin. Si nécessaire, appeler un centre antipoison ou un médecin. Ne rien faire ingérer à une personne inconsciente. En cas d'évanouissement, placez la personne en position latérale de sécurité et appelez un médecin immédiatement. Assurez-vous d'une bonne circulation d'air. Détacher tout ce qui pourrait être serré, comme un col, une cravate, une ceinture ou un ceinturon.

Symptoms:

Aucune donnée spécifique.

Immediate Medical Attention Required

La personne exposée peut avoir besoin de rester sous surveillance médicale pendant 48 heures.

Medical Treatment

Pas de traitement particulier.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solubility In Fat
Not available
State Under Standard Conditions
Not available
Ph
Non applicable. [DIN EN 1262]
Freezing Point
Not available
Flash Point
Vase clos: 39℃ (102.2ºF) [Pensky-Martens]
Critical Property
Dynamic Viscosity
Not available
Molecular Weight
Not available
Vapor Pressure
Not available
Crystallisation Point
Not available
Melting Point
Non disponible.
Critical Property
Physical State
Liquide.
Critical Property
Bulk Density
Not available
Solidification Point
Not available
Solubility In Water
Non soluble [OESO (TG 105)]
Colour Intensity
Not available
Auto Ignition Temperature
Not available
Cloud Point
Not available
Density
0.901 g/cm3 [DIN EN ISO 2811-1]
Critical Property
Odor
Non disponible.
Form
Not available
Boiling Point
149°C (300.2ºF)
Critical Property
Voc Content
Not available
Flammability
Non disponible.
Lower Explosive Limit
Non disponible.
Properties Status
Not available
Softening Point
Not available
Relative Density
Not available
Decomposition Temperature
Non disponible.
Appearance
Not available
Vapor Density
Non disponible.
Colour
Incolore.
Evaporation Rate
Not available
Partition Coefficient
Non applicable.
Odor Threshold
Non disponible.
Physical State Data
liquid
Kinematic Viscosity
610 mm2/s [DIN EN ISO 3219]
Metal Corrosion
Not available
Explosive Limits
Not available
Relative Evaporation Rate
Not available
Upper Explosive Limit
Non disponible.
Solubility
Non soluble [OESO (TG 105)]
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Utiliser uniquement dans un environnement bien aéré. Utiliser des enceintes fermées, une ventilation par aspiration à la source, ou d'autres systèmes de contrôle automatique intégrés afin de maintenir le seuil d'exposition du technicien aux contaminants en suspension dans l'air inférieur aux limites recommandées ou légales. Les moyens de contrôle automatiques intégrés devront permettre de maintenir les concentrations en gaz, en vapeur ou en poussière en dessous de tout seuil d'explosion. Utiliser un équipement de ventilation antidéflagrant.

Hand Protection

Le port de gants imperméables et résistants aux produits chimiques conformes à une norme approuvée, est obligatoire en tout temps lors de la manutention de produits chimiques si une évaluation des risques le préconise. En prenant en compte les paramètres indiqués par le fabricant de gants, vérifier pendant l'utilisation que les gants conservent leurs propriétés protectrices. Il est noté que le temps de claquage des gants peut différer d'un fabricant à l'autre. En cas de mélanges constitués de plusieurs substances, il est impossible d'estimer de façon précise le délai de sécurité des gants. Pour un contact prolongé ou fréquemment répété, des gants de classe de protection 6 (temps de rupture supérieur à 480 minutes selon la norme EN 374) sont recommandés. Gants recommandés : Viton ® ou Nitrile, épaisseur ≥ 0.38 mm. Pour un contact bref, des gants de classe de protection 2 ou classe supérieure (temps de rupture > 30 minutes selon la norme EN 374) sont recommandés. Gants recommandés : Nitrile, épaisseur ≥ 0.12 mm. Remplacer les gants à intervalles réguliers et en cas de signes de détérioration du matériau des gants. La performance et l'efficacité des gants peut être diminuée par des dommages physiques/chimiques et une conservation inadéquate. L'utilisateur doit vérifier que les types de gants qu'il choisit de porter pour la manipulation de ce produit est le plus approprié et prend en compte les conditions d'utilisation particulières, conformément aux indications stipulées dans l'évaluation des risques de l'utilisateur.

Eye Protection

Utiliser une protection oculaire conforme à une norme approuvée dès lors qu'une évaluation du risque indique qu'il est nécessaire d'éviter l'exposition aux projections de liquides, aux fines particules pulvérisées, aux gaz ou aux poussières. Si le contact est possible, porter les protections suivantes à moins que l'évaluation n'indique un degré supérieur de protection : lunettes de sécurité avec protections latérales.

Respiratory Protection

En fonction du danger et du risque d'exposition, choisir un appareil respiratoire conforme aux normes ou à la certification appropriées. Les appareils respiratoires doivent être utilisés conformément au programme de protection respiratoire afin de veiller à la pose conforme, la formation et d'autres aspects importants de l'utilisation.

Skin/Body Protection

Pour un contact prolongé ou fréquemment répété, des gants de classe de protection 6 (temps de rupture supérieur à 480 minutes selon la norme EN 374) sont recommandés. Gants recommandés : Viton ® ou Nitrile, épaisseur ≥ 0.38 mm. Pour un contact bref, des gants de classe de protection 2 ou classe supérieure (temps de rupture > 30 minutes selon la norme EN 374) sont recommandés. Gants recommandés : Nitrile, épaisseur ≥ 0.12 mm. Remplacer les gants à intervalles réguliers et en cas de signes de détérioration du matériau des gants. La performance et l'efficacité des gants peut être diminuée par des dommages physiques/chimiques et une conservation inadéquate. L'utilisateur doit vérifier que les types de gants qu'il choisit de porter pour la manipulation de ce produit est le plus approprié et prend en compte les conditions d'utilisation particulières, conformément aux indications stipulées dans l'évaluation des risques de l'utilisateur. L'équipement de protection personnel pour le corps devra être choisi en fonction de la tâche à réaliser ainsi que des risques encourus, et il est recommandé de le faire valider par un spécialiste avant de procéder à la manipulation du produit. En cas de risque d'inflammation lié à l'électricité statique, porter des vêtements de protection antistatiques. Pour une protection maximale contre les décharges d'électricité statique, les vêtements doivent inclure une combinaison, des chaussures et des gants antistatiques. Pour plus d'informations sur les exigences et les méthodes d'essais des matières et des modèles, consulter la norme européenne EN 1149. Des chaussures adéquates et toutes mesures de protection corporelle devraient être déterminées en fonction de l'opération effectuée et des risques impliqués, et devraient être approuvées par un spécialiste avant toute manipulation de ce produit.

Environmental Exposure Controls

Il importe de tester les émissions provenant des systèmes de ventilation ou du matériel de fabrication pour vous assurer qu'elles sont conformes aux exigences de la législation sur la protection de l'environnement. Dans certains cas, il sera nécessaire d'équiper le matériel de fabrication d'un épurateur de gaz ou d'un filtre ou de le modifier techniquement afin de réduire les émissions à des niveaux acceptables.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1263

Proper Shipping Name

PEINTURES

Transport Hazard Class

3

Packing Group

III

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for YACHT VERNIS SATIN INCOLORE?

The signal word for this substance is "warning".

What is the physical form of YACHT VERNIS SATIN INCOLORE?

YACHT VERNIS SATIN INCOLORE is a liquide. with incolore. color. It has non disponible. odor.

What is the solubility of YACHT VERNIS SATIN INCOLORE?

Non soluble [OESO (TG 105)]

What is YACHT VERNIS SATIN INCOLORE used for?

Peinture en phase solvant à usage extérieur.

What are the hazard statements for YACHT VERNIS SATIN INCOLORE?

This substance has 2 hazard statements: H226: Liquide et vapeurs inflammables. H336: Peut provoquer somnolence ou vertiges.

What is the melting point of YACHT VERNIS SATIN INCOLORE?

The melting point is Non disponible. and the boiling point is 149°C (300.2ºF).