NO SIGNAL WORD pte SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
silicone actate sanitaire-Blanc carrelage
Product Code
08925608

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Mastic

Overview

silicone actate sanitaire-Blanc carrelage is a pte substance commonly used mastic.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Wrth Belux N.V - S.A.

national supplier

Everdongenlaan 29 2300 Turnhout

BE

+32 (0)14 44 55 66

+32 (0)14 44 55 67

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+32 (0)70 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hydrocarbures, C13-C23, nalcanes, isoalcanes, cycliques, <0,03% aromatiques
EC: 265-148-2
N/A 10-20% Hazardous
triacetoxyethylsilane
EC: 241-677-4
17689-77-9 1-3% Hazardous
thyle oligomrique et actoxysilanes de mthyle N/A 1-3% Hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

En cas d'inhalation, dplacer l'air frais. Faire appel une assistance mdicale si des symptmes apparaissent.

Skin Contact

Laver l'eau et au savon par prcaution. Faire appel une assistance mdicale si des symptmes apparaissent.

Eye Contact

Rincer les yeux l'eau par mesure de prcaution. Si une irritation se dveloppe et persiste, consulter un mdecin.

Symptoms:

Si une irritation se dveloppe et persiste.

Ingestion/Swallowing

En cas d'ingestion, NE PAS faire vomir. Faire appel une assistance mdicale si des symptmes apparaissent. Rincer soigneusement la bouche avec de l'eau.

Immediate Medical Attention Required

Faire appel une assistance mdicale si des symptmes apparaissent. Si une irritation oculaire se dveloppe et persiste, consulter un mdecin.

Medical Treatment

Effectuer un traitement symptomatique et d'appoint.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Evaporation Rate
Donne non disponible
Decomposition Temperature
Donne non disponible
Kinematic Viscosity
Donne non disponible
Melting Point
Donne non disponible
Critical Property
Upper Explosive Limit
Donne non disponible
Voc Content
Not available
Relative Density
Not available
Physical State
pte
Critical Property
Density
1,01 g/cm (23 C)
Critical Property
Appearance
pte
Freezing Point
Donne non disponible
Properties Status
Not available
Cloud Point
Not available
Metal Corrosion
Not available
Flash Point
- 250 C
Critical Property
Colour
de couleur /color(e)
Crystallisation Point
Not available
Solubility In Water
insoluble
Solubility In Fat
Not available
Relative Evaporation Rate
Not available
Physical State Data
solid
Colour Intensity
Not available
Solubility
insoluble
Ph
Donne non disponible
Flammability
Inflammable (voir point d'ignition)
Form
Not available
Softening Point
Not available
Boiling Point
Donne non disponible
Critical Property
Auto Ignition Temperature
env. 400 C
Bulk Density
Not available
Solidification Point
Not available
Dynamic Viscosity
env. 800.000 mPa.s
State Under Standard Conditions
Not available
Vapor Density
Not available
Partition Coefficient
Non applicable
Molecular Weight
Not available
Odor Threshold
Donne non disponible
Explosive Limits
Not available
Vapor Pressure
Donne non disponible
Lower Explosive Limit
Donne non disponible
Odor
nausabonde
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Des substances dangereuses peuvent se former lors de l'utilisation (voir chapitre 10). Assurer une ventilation adquate, surtout dans les endroits clos. Rduire au minimum les concentrations d'exposition au travail.

Hand Protection

Matriel : caoutchouc butyle, Dlai de rupture : - 480 min, paisseur du gant : - 0,3 mm. Matriel : Caoutchouc nitrile, Dlai de rupture : 60 - 120 min, paisseur du gant : - 0,1 mm. Remarques : Le choix du type de gants de protection contre les produits chimiques doit tre effectu en fonction de la concentration et de la quantit des substances dangereuses propres aux postes de travail. Dans le cas d'applications spciales, il est recommand de se renseigner auprs du fabricant de gants sur la rsistance aux produits chimiques des gants de protection indiqus ci-dessus. Se laver les mains avant les pauses et la fin de la journe de travail.

Eye Protection

Veillez respecter toutes les exigences locales et/ou nationales applicables en slectionnant des mesures de protection destines un travail spcifique. Porter les quipements de protection individuelle suivants: Lunettes de scurit. Veuillez toujours porter des lunettes de protection lorsqu'on ne peut exclure un risque de contact du produit avec les yeux par inadvertance. L'quipement doit tre conforme la norme EN NBN 166

Respiratory Protection

Utiliser une protection respiratoire adquate sauf en prsence d'une ventilation locale par aspiration ou s'il est dmontr que l'exposition est dans les limites prconises par les directives d'exposition. L'quipement doit tre conforme la norme EN NBN 133. Filtre de type : Type mixte protgeant des particules et des vapeurs organiques (A-P)

Skin/Body Protection

Nettoyer soigneusement la peau aprs tout contact avec le produit.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for silicone actate sanitaire-Blanc carrelage?

The signal word for this substance is "no signal word".

What is the physical form of silicone actate sanitaire-Blanc carrelage?

silicone actate sanitaire-Blanc carrelage is a pte appearing as pte with de couleur /color(e) color. It has nausabonde odor.

What is the solubility of silicone actate sanitaire-Blanc carrelage?

insoluble

What is silicone actate sanitaire-Blanc carrelage used for?

Mastic

What is the melting point of silicone actate sanitaire-Blanc carrelage?

The melting point is Donne non disponible and the boiling point is Donne non disponible.