NextSDS Logo
We

Weller Pyropen Refill, 75 ml / 42g

DANGER Gas: gaz comprimé SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Weller Pyropen Refill, 75 ml / 42g
Product Form
gaz
Product Code
T00516160 99_49 / T0051605999 / T00516160 90

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

UFI Code
5JK0-G0US-500S-Q60P

Unique Formula Identifier - for poison centres and emergency response

Uses Information

Identified Uses
gaz combustible

Overview

Weller Pyropen Refill, 75 ml / 42g is a gas substance commonly used gaz combustible.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Danger)

Hazard Classifications

Flam. Gas Category 1A H220
Contient un gaz sous pression H280

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H220: Gaz extrêmement inflammable.
  • H280: Contient un gaz sous pression; peut exploser sous l'effet de la chaleur.

Precautionary Statements

  • P102: Tenir hors de portée des enfants.
  • P210: Tenir à l’écart de la chaleur, des surfaces chaudes, des étincelles, des flammes nues et de toute autre source d’ignition. Ne pas fumer.
  • P377: Fuite de gaz enflammé: Ne pas éteindre si la fuite ne peut pas être arrêtée sans danger.
  • P381: En cas de fuite, éliminer toutes les sources d'ignition.
  • P403: Stocker dans un endroit bien ventilé.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Weller Tools GmbH

undefined

Carl-Benz-Strasse 2 Germany-74354 Besigheim

DE

+49 7143 580-0

+49 7143 580-108

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

GIZ Mainz

+49 6131 - 19240

DE

Languages: DE, EN, FR

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

mixture / Gemisch / mélange / mezcla / mistura / mengsel / Blandning / Blanding / seos / mieszanina / segu / maisijums / misinys / zmes / mesanica / karisim / amestec / keverék / μίγμα

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
propane
EC: 200-827-9
74-98-6 10-25% Hazardous
isobutane
EC: 200-857-2
75-28-5 25-50% Hazardous
butane
EC: 203-448-7
106-97-8 50-100% Hazardous

Composition Notes

Indications diverses Isobutane & Butane (<0.1% Butadien)

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Veiller à un apport d'air frais. En cas d'irritation des voies respiratoires, consulter un médecin.

Symptoms:

irritation des voies respiratoires

Skin Contact

Après contact avec la peau, se laver immédiatement et abondamment avec eau et savon.

Eye Contact

en cas de contact avec les yeux, paupière ouverte rincer immédiatement à l'eau courante 10 à 15 minutes et consulter un ophtamologiste.

Immediate Medical Attention Required

En cas de doute ou s'il y a des symptômes, demander un conseil médical. En cas d'irritation des voies respiratoires, consulter un médecin. En cas de contact avec les yeux, consulter un ophtamologiste.

Fire Safety

Fire Fighting Measures & Emergency Response

Fire suppression methods, extinguishing media, and firefighting safety procedures

Suitable Extinguishing Media

Dioxyde de carbone (CO2), Poudre d'extinction, mousse résistante à l'alcool, Jet d'eau pulvérisée

Unsuitable Extinguishing Media

Jet d'eau à grand débit

Specific Fire Hazards

Aucune donnée disponible

Fire Fighting Instructions

Utiliser un jet d'eau dans le périmètre de danger pour la protection des personnes et le refroidissement des récipients.

Firefighter Protection Equipment

ne pas respirer les gaz d'explosion et d'incendie. Porter une combinaison de protection contre les substances chimiques.

Spill Response

Accidental Release Measures & Spill Response

Emergency spill cleanup procedures, containment methods, and environmental protection

Emergency Procedures

Eloigner toute source d'ignition. Assurer une aération suffisante. Evacuer les personnes en lieu sûr.

Environmental Precautions

Ne nécessite aucune mesure de prévention particulière pour la protection de l'environnement.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Appearance
Gas
Crystallisation Point
Not available
Odor
SOUFRE
Ph
non déterminé
Dynamic Viscosity
Not available
Solubility In Fat
non déterminé
Bulk Density
Not available
Vapor Density
Not available
Metal Corrosion
Not available
Kinematic Viscosity
non déterminé
Decomposition Temperature
non déterminé
State Under Standard Conditions
Not available
Density
ca.0,56 g/cm³
Critical Property
Colour
incolore
Physical State
Gas: gaz comprimé
Critical Property
Molecular Weight
Not available
Solidification Point
Not available
Voc Content
100%
Evaporation Rate
Not available
Boiling Point
-44 °C
Critical Property
Form
Not available
Upper Explosive Limit
10,9 Vol-%
Lower Explosive Limit
1,5 Vol-%
Odor Threshold
non déterminé
Properties Status
Not available
Colour Intensity
Not available
Cloud Point
Not available
Softening Point
Not available
Solubility In Water
insoluble
Partition Coefficient
non déterminé
Flammability
non déterminé
Flash Point
-97 °C
Critical Property
Freezing Point
non dtermin
Melting Point
non déterminé
Critical Property
Physical State Data
gas
Auto Ignition Temperature
365 °C
Relative Density
ca.0,56 g/cm
Vapor Pressure
2 - 3,5 bar
Solubility
Not available
Explosive Limits
Not available
Relative Evaporation Rate
Not available
Handling & Storage

Safe Handling & Storage Procedures

Industrial handling precautions, storage conditions, and workplace safety requirements

Handling Precautions

Après usage, refermer aussitôt la capsule de fermeture.

Storage Conditions

Conserver les récipients bien fermés dans un endroit frais bien ventilé.

Protéger contre: Forte chaleur, Radiations UV/rayonnement solaire.

Fire Prevention Measures

Conserver à l'écart de toute flamme ou source d'étincelles - Ne pas fumer. Tenir à l'écart de toute source de chaleur (p. ex. surfaces chaudes), des étincelles et des flammes directes. Ne pas vaporiser sur des flammes ou des objets incandescents.

Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Adequate ventilation to prevent insufficient ventilation.

Hand Protection

Matériau approprié: NBR (Caoutchouc nitrile) EN374. Caractéristiques exigées: imperméable au gaz. Temps de pénétration >480 min. Le modèle des gants spécial chimie doit être choisi en fonction des concentrations et quantités des substances chimiques spécifiques au poste.

Eye Protection

Protection oculaire: non indispensable.

Respiratory Protection

Une protection respiratoire est nécessaire lors de: ventilation insuffisante.

Environmental Exposure Controls

Voir rubrique 7. D'autres mesures complémentaires ne sont pas nécessaires.

Section 10

Chemical Stability & Reactivity Data

Chemical stability, hazardous reactions, and incompatible materials information

Conditions to Avoid

Évitez les températures élevées ou la lumière directe du soleil.

Section 13

Waste Disposal & Treatment Methods

Waste disposal procedures, treatment methods, and regulatory compliance requirements

Waste Treatment Methods

Les emballages entièrement vides peuvent être revalorisés. Revaloriser en se conformant aux dispositions administratives.

Waste Classification Codes

160500 gaz en récipients à pression et produits chimiques mis au rebut EWC
160000 DÉCHETS NON DÉCRITS AILLEURS DANS LA LISTE EWC
160505 gaz en récipients à pression autres que ceux visés à la rubrique 16 05 04 EWC
Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

2037

Proper Shipping Name

Receptacles, small, containing gas

Transport Hazard Class

2

ADR Transport Precautions

non applicable

IMDG Maritime Transport Precautions

non applicable

IATA Air Transport Precautions

non applicable

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Weller Pyropen Refill, 75 ml / 42g?

The signal word for this substance is "danger".

What is the physical form of Weller Pyropen Refill, 75 ml / 42g?

Weller Pyropen Refill, 75 ml / 42g is a gas: gaz comprimé appearing as gas with incolore color. It has soufre odor.

What is Weller Pyropen Refill, 75 ml / 42g used for?

gaz combustible

What are the hazard statements for Weller Pyropen Refill, 75 ml / 42g?

This substance has 2 hazard statements: H220: Gaz extrêmement inflammable. H280: Contient un gaz sous pression; peut exploser sous l'effet de la chaleur.

What is the melting point of Weller Pyropen Refill, 75 ml / 42g?

The melting point is non déterminé and the boiling point is -44 °C.