Basic Product Information

Product Name
LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C
Product Code
SN62 362 5C

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Fil braser

Overview

LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C commonly used fil braser.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

warning (Attention)

Hazard Classifications

Skin Sens. Category 1 H317

GHS Hazard Pictograms & Safety Symbols

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H317: Peut provoquer une allergie cutane.

Precautionary Statements

  • P261: viter de respirer les manations.
  • P280: Porter des gants de protection.
  • P333+P313: En cas dirritation ou d'ruption cutane: consulter un mdecin.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Henkel Westerlo AE Belgium

national supplier

πŸ“

Nijverheidsstraat 7 2260 Westerlo Belgique

🌍

BE

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

πŸ“ž

+32 70 222 076

🌍

BE

πŸ•’

24 h

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
tain
EC: 231-141-8
7440-31-5 50-100% βœ“ Non-hazardous
Plomb
EC: 231-100-4
7439-92-1 25-50% βœ“ Non-hazardous
Colophane
EC: 232-475-7
8050-09-7 1-3% ⚠️ Hazardous
Argent
EC: 231-131-3
7440-22-4 1-3% βœ“ Non-hazardous

Composition Notes

Voir texte complet des phrases H et autres abrviations dans paragraphe 16 "Autres informations". Les substances non classifies peuvent avoir une valeur limite d'exposition sur le lieu de tavail.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

🫁 Inhalation Exposure

Amener au grand air. Si les symptomes persistent, faire appel un mΓ©decin.

Symptoms:

Les fumes de flux peuvent Γͺtre irritantes pour le nez, la gorge et les organes respiratoires.

πŸ–οΈ Skin Contact

Rincer Γ  l'eau courante et au savon. Si l'irritation persiste, consulter un mΓ©decin.

Symptoms:

Eruption cutanΓ©e, urticaire.

πŸ‘οΈ Eye Contact

Rincer les yeux Γ  grande eau pendant au moins 5 minutes. Si l'irritation persiste consulter un mΓ©decin.

Symptoms:

irritation

🍽️ Ingestion/Swallowing

Rincer l'intΓ©rieur de la bouche, boire 1 Γ  2 verres d'eau, ne pas faire vomir, consulter un mΓ©decin.

🚨 Immediate Medical Attention Required

Consulter un mΓ©decin si les symptΓ΄mes persistent (inhalation, peau, yeux) ou en cas d'ingestion.

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

πŸ§ͺ Physical State
solide
Critical Property
πŸ“Š Physical State Data
solid
πŸ“Š State Under Standard Conditions
Not available
πŸ‘οΈ Appearance
Not available
🎨 Colour
Gris
πŸ“Š Colour Intensity
Not available
πŸ“Š Form
Not available
πŸ‘ƒ Odor
Pas
πŸ“Š Odor Threshold
Il n'y a pas de donnes / Non applicable
πŸ§ͺ Ph
Non applicable
🧊 Melting Point
Alliage de soudure
Critical Property
πŸ’¨ Boiling Point
Indtermin
Critical Property
πŸ”₯ Flash Point
- 100 C (> 212 F)
Critical Property
πŸ“Š Freezing Point
Not available
πŸ“Š Softening Point
Not available
πŸ“Š Solidification Point
Il n'y a pas de donnes / Non applicable
πŸ“Š Cloud Point
Not available
πŸ“Š Crystallisation Point
Not available
πŸ“Š Relative Evaporation Rate
Not available
πŸ’¨ Evaporation Rate
Il n'y a pas de donnes / Non applicable
πŸ’¨ Vapor Pressure
Non applicable
πŸ“Š Vapor Density
Non disponible
πŸ“Š Relative Density
Not available
πŸ“Š Bulk Density
Il n'y a pas de donnes / Non applicable
βš–οΈ Density
8,5 g/cm3
Critical Property
πŸ”₯ Flammability
Il n'y a pas de donnes / Non applicable
πŸ“Š Upper Explosive Limit
Il n'y a pas de donnes / Non applicable
πŸ“Š Lower Explosive Limit
Il n'y a pas de donnes / Non applicable
πŸ“Š Explosive Limits
Not available
πŸ“Š Auto Ignition Temperature
Il n'y a pas de donnes / Non applicable
πŸ“Š Decomposition Temperature
Il n'y a pas de donnes / Non applicable
πŸ’§ Solubility
Insoluble
πŸ“Š Partition Coefficient
Indtermin
πŸ“Š Solubility In Water
Not available
πŸ“Š Solubility In Fat
Not available
πŸ“Š Molecular Weight
Not available
πŸ“Š Voc Content
Not available
πŸ“Š Metal Corrosion
Not available
πŸ“Š Dynamic Viscosity
Il n'y a pas de donnes / Non applicable
πŸ“Š Kinematic Viscosity
Il n'y a pas de donnes / Non applicable
πŸ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

🏭 Engineering Controls

Extraction ncessaire des fumes mises pendant le brasage. Lorsque raisonnablement faisable, ceci devrait se faire par aspiration aux postes de travail et une extraction gnrale convenable. Veiller une bonne ventilation/aspiration.

🧀 Hand Protection

Gants de protection rsistant aux produits chimiques (EN 374) Matires appropries un contact de courte dure ou des projections (recommandation: indice de protection au moins 2, soit > 30 minutes de temps de permation selon EN 374): Caoutchouc nitrile (NBR; >= 0,4 mm d'paisseur de couche) Matires appropries galement un contact direct et plus long (recommandation: indice de protection 6, soit > 480 minutes de temps de permation selon EN 374): Caoutchouc nitrile (NBR; >= 0,4 mm d'paisseur de couche) Les indications faites sont bases sur la littrature et sur les informations fournies par les fabricants de gants ou sont dduites par analogie de matires similaires. Il faut tenir compte que la dure d'utilisation d'un gant de protection contre les produits chimiques dans la pratique peut tre sensiblement plus courte que le temps de permation dtermin selon EN 374 en raison de multiples facteurs d'influence (comme la temprature p. ex.). Le gant doit tre remplac s'il prsente des signes d'usure.

πŸ‘οΈ Eye Protection

Des lunettes de scurit avec protections latrales ou des lunettes descurit pour produits chimiques devraient tre portes s'il y un riqued'claboussures.

😷 Respiratory Protection

Assurer une aration et une ventilation suffisantes. Il convient de porter un masque agr ou un respirateur avec unecartouche de vapeur organique si le produit est utilis dans un endroitmal ventil. En cas de formation d'arosol, nous recommandons de porter un quipement de protection respiratoire appropri avec un filtre ABEK P2. Cette recommandation devra tre adapte en fonction des conditions locales.

🦺 Skin/Body Protection

Porter un vtement de protection appropri.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C?

The signal word for this substance is "warning".

What is the physical form of LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C?

LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C is a solide with gris color. It has pas odor.

What is the solubility of LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C?

Insoluble

What is LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C used for?

Fil braser

What are the hazard statements for LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C?

This substance has 1 hazard statements: H317: Peut provoquer une allergie cutane.

What is the melting point of LOCTITE 362 SN62 5C 0.56MM R known as SN62 362 5C?

The melting point is Alliage de soudure and the boiling point is Indtermin.