Identification
Product identifiers, regulatory numbers, and supplier information
Product Information
- Product Name
- SIGMADUR 580 HARDENER
Regulatory Identifiers
- CAS Number
- N/A
Identified Uses
verf
Manufacturers & Suppliers
PPG Coatings Nederland B.V.
manufacturer
Amsterdamseweg 14, 1422 AD Uithoorn
+31 (0)297 541234
Emergency Contacts
Emergency Contact
+31 (0)20 4075210
Hazard Identification
GHS classification, signal word, pictograms, and hazard statements
GHS Pictograms
Get a free compliance audit
Upload your SDS inventory and get a detailed compliance report
Composition / Information on Ingredients
Chemical components, concentration ranges, and hazardous substance identification
De producent verklaart dat voor de in hoofdstuk 3 niet vermelde R-zinnen, de totale hoeveelheid gevaarlijke componenten beneden de grens liggen. Het benzeengehalte van dit product is minder dan 0,1%. Nota P en H zijn van toepassing.
| Chemical Name | CAS Number | Concentration | Hazardous |
|---|---|---|---|
| n-butylacetaat EC: 204-658-1 | 123-86-4 | 2.5 - 10% | Yes |
| solvent-nafta (aardolie), licht aromatisch EC: 265-199-0 | 64742-95-6 | 2.5 - 10% | Yes |
| hexamethyleen-1,6-diisocyanaat EC: 212-485-8 | 822-06-0 | 0.1 - 0.5% | Yes |
| alifatisch polyisocyanaat | --- | 75 - 100% | Yes |
Notes
Indien meerdere ingredienten met gelijke namen of nummers verschijnen hebben deze verschillende gevaren eigenschappen, bijvoorbeeld vlampunt.
First Aid Measures
Emergency procedures for chemical exposure incidents
Verse lucht toedienen. Betreffende persoon in rusttoestand brengen en warm houden. Bij onregelmatige ademhaling of ademstilstand kunstmatige beademing toepassen. Bij bewusteloosheid stabiele zijligging toepassen.
Verontreinigde kleding onmiddellijk uittrekken. De huid grondig wassen met water en zeep of een erkende huidreiniger. Als gemorst product op de kleding vlam vat, spoelen met ruim water. Verwijder loszittende kleding.
Oogleden openhouden en minstens 10 minuten lang rijkelijk met zuiver, vloeiend water spoelen. Contactlenzen uitdoen.
Het slachtoffer laten rusten.
Immediate Medical Attention
Als de ziekteverschijnselen niet van voorbijgaande aard zijn en in geval van twijfel dient medische hulp te worden ingeroepen. Medisch advies inwinnen (na oogcontact en inademing). Bij inslikken direkt arts raadplegen. Medische hulp inroepen (bij verbranding).
Firefighting Measures
Extinguishing media, specific hazards, and firefighter protection
The data for this section has not been processed yet.
Accidental Release Measures
Spill cleanup procedures, containment, and environmental protection
The data for this section has not been processed yet.
Related Products
Similar products with comparable safety profiles
Handling and Storage
Safe handling precautions, storage conditions, and workplace requirements
The data for this section has not been processed yet.
Exposure Controls / PPE
Occupational exposure limits, engineering controls, and protective equipment
Ventilation must be present in spray booths for spray particles and solvent vapors. If dry sanding cannot be avoided, respiratory protection with fresh air supply must be used. Minimum ventilation required for 1 liter product to reach MAC: 570 m3/l (Basis: MAC (NL)); to reach 10% OEG: 22 m3/l.
For prolonged or repeated contact, use chemical-resistant gloves, as indicated in standard EN 374: Protective gloves against chemicals and microorganisms. Recommended gloves: Nitrile rubber. Minimum breakthrough time: 30 min. For prolonged and regular contact, a glove with protection class 6 (breakthrough time more than 480 minutes according to EN 374) is recommended. For short contact, a glove with protection class 2 or higher (breakthrough time greater than 30 minutes according to EN 374) is recommended.
Wearing chemical-resistant safety glasses is mandatory. Eye protection is required.
If employees are in a spray booth, ventilation must be present for spray particles and solvent vapors. In these circumstances, they must wear a fresh-air hood during the spraying process until the concentration has fallen below the MAC value. If dry sanding cannot be avoided, respiratory protection with fresh air supply must be used. A combi-mask P1A1 is also mentioned.
Personnel must wear protective clothing. After skin contact, wash thoroughly. Work clothing should not consist of textiles that show dangerous melting behavior in case of fire. Wearing anti-static shoes is mandatory.
See national legislation in chapter 15 for legislation regarding environmental protection.
Physical and Chemical Properties
Appearance, physical state, melting point, boiling point, and material characteristics
Stability and Reactivity
Chemical stability, hazardous reactions, and incompatible materials
The data for this section has not been processed yet.
Ecological Information
Environmental toxicity, biodegradation, and bioaccumulation data
The data for this section has not been processed yet.
Disposal Considerations
Waste treatment methods, disposal recommendations, and waste codes
The data for this section has not been processed yet.
Transport Information
UN numbers, shipping names, transport classes, and regulatory requirements
- UN Number
- 1263
- Shipping Name
- PAINT RELATED MATERIAL
- Transport Class
- 3
- Packing Group
- III
Regulatory Information
Chemical regulations, safety assessments, and compliance status
The data for this section has not been processed yet.
Frequently Asked Questions
Common questions about safety, handling, and properties
What is the hazard signal word for SIGMADUR 580 HARDENER?
The signal word is na: r-phrases.
What is SIGMADUR 580 HARDENER used for?
verf