NextSDS Logo
Ci

Citronensure-Monohydrat zur Analyse ACS,ISO

NO SIGNAL WORD vast SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Citronensure-Monohydrat zur Analyse ACS,ISO
Product Code
100244

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Overview

Citronensure-Monohydrat zur Analyse ACS,ISO .

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Eye Irrit.

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA

manufacturer

64271 Darmstadt * Germany

DE

++49 (0)6151 72-0

++49 (0)6151 727780

Merck Nederland

national supplier

1005 Amsterdam

NL

Merck-Belgolabo

national supplier

3090 Overijse

BE

Vel

local supplier

3001 Leuven

BE

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Merck Nederland

020 4808400

NL

Merck-Belgolabo

02 6860711

BE

Vel

016 391811

BE

Merck KGAA

++49 (0)6151 722440

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
2-Hydroxy-1,2,3-propantricarbonsure-Monohydrat
EC: 611-842-9
5949-29-1 Not specified Non-hazardous
First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

frisse lucht.

Skin Contact

met ruim water afwassen. Gecontamineerde kleding verwijderen.

Eye Contact

met ruim water met open gehouden ooglid spoelen

Ingestion/Swallowing

Direct veel water laten drinken (eventueel meerdere liters).

Immediate Medical Attention Required

Oogarts waarschuwen. Arts waarschuwen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Physical State
vast
Critical Property
Physical State Data
solid
State Under Standard Conditions
Not available
Appearance
Not available
Colour
wit
Colour Intensity
Not available
Form
Not available
Odor
geurloos
Odor Threshold
Not available
Ph
~ 1.8
Melting Point
- 100
Critical Property
Boiling Point
135 - 153
Critical Property
Flash Point
niet beschikbaar
Critical Property
Freezing Point
Not available
Softening Point
Not available
Solidification Point
Not available
Cloud Point
Not available
Crystallisation Point
Not available
Relative Evaporation Rate
Not available
Evaporation Rate
Not available
Vapor Pressure
< 0.1 hPa
Vapor Density
Not available
Relative Density
Not available
Bulk Density
~ 800 - 1000 kg/m3
Density
1.54 g/cm3
Critical Property
Flammability
Not available
Upper Explosive Limit
niet beschikbaar
Lower Explosive Limit
niet beschikbaar
Explosive Limits
Not available
Auto Ignition Temperature
niet beschikbaar
Decomposition Temperature
Not available
Solubility
Not available
Partition Coefficient
1.72
Solubility In Water
- 1630 g/I
Solubility In Fat
Not available
Molecular Weight
Not available
Voc Content
Not available
Metal Corrosion
Not available
Dynamic Viscosity
Not available
Kinematic Viscosity
Not available
Properties Status
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

benodigd

Eye Protection

benodigd

Respiratory Protection

nodig indien stofvorming plaatsvindt.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Citronensure-Monohydrat zur Analyse ACS,ISO?

The signal word for this substance is "no signal word".

What is the physical form of Citronensure-Monohydrat zur Analyse ACS,ISO?

Citronensure-Monohydrat zur Analyse ACS,ISO is a vast with wit color. It has geurloos odor.

What is the melting point of Citronensure-Monohydrat zur Analyse ACS,ISO?

The melting point is - 100 and the boiling point is 135 - 153.