NextSDS Logo
Az

Azijnzuur 100% watervrij voor analyse EMSURE

DANGER vloeibaar SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Azijnzuur 100% watervrij voor analyse EMSURE
Product Form
watervrij
Product Code
100063

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagens voor analyse, Chemische productie

Overview

Azijnzuur 100% watervrij voor analyse EMSURE commonly used reagens voor analyse, chemische productie.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Liq. Category 3 H226
Met. Corr. Category 1 H290
Skin Corr. Category 1A H314

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS05 GHS Hazard Pictogram: Corrosive hazard - Materials that can cause severe skin burns and eye damage

GHS05

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H226: Ontvlambare vloeistof en damp.
  • H290: Kan bijtend zijn voor metalen.
  • H314: Veroorzaakt ernstige brandwonden en oogletsel.

Precautionary Statements

  • P210: Verwijderd houden van warmte.
  • P280: Beschermende handschoenen/ beschermende kleding/ oogbescherming/ gelaatsbescherming dragen.
  • NA INSLIKKEN: de mond spoelen - GEEN braken opwekken.
  • BIJ CONTACT MET DE OGEN: voorzichtig afspoelen met water gedurende een aantal minuten; contactlenzen verwijderen, indien mogelijk; blijven spoelen.
  • NA (mogelijke) blootstelling: Onmiddellijk een ANTIGIFCENTRUM of een arts raadplegen.

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA

global supplier

๐Ÿ“

64271 Darmstadt, Duitsland

๐ŸŒ

DE

๐Ÿ“ž

+49 6151 72-2440

๐Ÿ“ 

+49 6151 727780

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Merck KGaA

๐Ÿ“ž

+49 6151 722440

๐ŸŒ

DE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Azijnzuur (ijsazijn) 100% watervrij

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Azijnzuur
EC: 200-580-7
64-19-7 100% โš ๏ธ Hazardous

Composition Notes

De veiligheidsinformatiebladen van de catalogusartikelen staan ter beschikking op www.merckgroup.com. Voor de volledige text van H-zinnen zoals vermeld in deze rubriek, zie rubriek 16.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Na inademen: frisse lucht. Arts waarschuwen.

Symptoms:

Kortademigheid

๐Ÿ–๏ธ Skin Contact

Verontreinigde kleding onmiddellijk uittrekken. Huid met water afspoelen/ afdouchen. Onmiddellijk een arts waarschuwen.

Symptoms:

Irritatie en corrosie

๐Ÿ‘๏ธ Eye Contact

Na oog contact: uitspoelen met ruim voldoende water. Onmiddellijk een oogarts raadplegen. Contactlenzen uitnemen.

Symptoms:

Gevaar voor troebelheid van de cornea. Gevaar voor blindheid!

๐Ÿฝ๏ธ Ingestion/Swallowing

Slachtoffer water laten drinken (niet meer dan twee glazen), braken voorkomen (perforatiegevaar!). Onmiddellijk een arts waarschuwen. Niet proberen te neutraliseren.

Symptoms:

maagkrampen, Misselijkheid, Braken, Collaps van de bloedsomloop, shock

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
vloeibaar
Critical Property
๐Ÿ“Š Physical State Data
liquid
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Not available
๐ŸŽจ Colour
kleurloos
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
vloeibaar
๐Ÿ‘ƒ Odor
bijtend
๐Ÿ“Š Odor Threshold
0,2 - 100,1 ppm
๐Ÿงช Ph
2,5
๐ŸงŠ Melting Point
17 C
Critical Property
๐Ÿ’จ Boiling Point
116 - 118 C
Critical Property
๐Ÿ”ฅ Flash Point
39 C
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
Geen gegevens beschikbaar.
๐Ÿ’จ Vapor Pressure
15,4 hPa
๐Ÿ“Š Vapor Density
Not available
๐Ÿ“Š Relative Density
Geen gegevens beschikbaar.
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
1,05 g/cm3
Critical Property
๐Ÿ”ฅ Flammability
Niet van toepassing
๐Ÿ“Š Upper Explosive Limit
19,9 %(V)
๐Ÿ“Š Lower Explosive Limit
4 %(V)
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
Geen gegevens beschikbaar.
๐Ÿ“Š Decomposition Temperature
Distilleerbaar in oorspronkelijke staat bij normale druk.
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
log Pow: -0,17 (25 C) (experimenteel) (ECHA) Een bio-accumulatie is niet te verwachten.
๐Ÿ“Š Solubility In Water
602,9 g/l
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Kan bijtend zijn voor metalen.
๐Ÿ“Š Dynamic Viscosity
1,22 mPa.s
๐Ÿ“Š Kinematic Viscosity
1,17 mm2/s
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Technische maatregelen en geschikte werkprocedures zouden prioriteit moeten hebben boven het gebruik van persoonlijke beschermingsmiddelen. Zie paragraaf 7.1.

๐Ÿงค Hand Protection

Voor volledig contact: butylrubber handschoenen, 0,7 mm dikte, doorbraaktijd > 480 min. Voor spatcontact: Natuurlijk latex handschoenen, 0,6 mm dikte, doorbraaktijd > 30 min. Handschoenen moeten voldoen aan EG regeling 89/686/EEG en EN374 (bijv. KCL 898 Butoject, KCL 706 Lapren).

๐Ÿ‘๏ธ Eye Protection

Nauw aansluitende veiligheidsstofbril

๐Ÿ˜ท Respiratory Protection

Nodig indien dampen/aerosolen gevormd worden. Aanbevolen filtertype: Filter E-(P2). Onderhoud, reiniging en beproeving van adembeschermingstoestellen moeten worden uitgevoerd volgens de voorschriften van de leverancier en gedocumenteerd.

๐Ÿฆบ Skin/Body Protection

Vlamvertragende, antistatische beschermingskleding.

๐ŸŒ Environmental Exposure Controls

Product niet in de riolering laten komen. Risico op explosie.

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

UN 2789

๐Ÿ“ฆ Proper Shipping Name

ACETIC ACID, GLACIAL

โš ๏ธ Transport Hazard Class

8 (3)

๐Ÿ“‹ Packing Group

II

๐Ÿš› ADR Transport Precautions

ja

๐Ÿšข IMDG Maritime Transport Precautions

ja

โœˆ๏ธ IATA Air Transport Precautions

nee

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Azijnzuur 100% watervrij voor analyse EMSURE?

The signal word for this substance is "danger".

What is the physical form of Azijnzuur 100% watervrij voor analyse EMSURE?

Azijnzuur 100% watervrij voor analyse EMSURE is a vloeibaar with kleurloos color. It has bijtend odor.

What is Azijnzuur 100% watervrij voor analyse EMSURE used for?

Reagens voor analyse, Chemische productie

What are the hazard statements for Azijnzuur 100% watervrij voor analyse EMSURE?

This substance has 3 hazard statements: H226: Ontvlambare vloeistof en damp. H290: Kan bijtend zijn voor metalen. H314: Veroorzaakt ernstige brandwonden en oogletsel.

What is the melting point of Azijnzuur 100% watervrij voor analyse EMSURE?

The melting point is 17 C and the boiling point is 116 - 118 C.