NextSDS Logo
3M

3M™ Cavilon™ No Sting Barrier Film Spray (IO) Cat. # 3346, 3346E, 3346P

NO SIGNAL WORD Vloeistof SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
3M™ Cavilon™ No Sting Barrier Film Spray (IO) Cat. # 3346, 3346E, 3346P
Product Code
7000086397

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Huidbeschermende Barrièrefilm.

Overview

3M™ Cavilon™ No Sting Barrier Film Spray (IO) Cat. # 3346, 3346E, 3346P is a heldere kleurloze vloeistof substance commonly used huidbeschermende barrièrefilm..

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

Hazard Classifications

Not Classified

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

3M Belgium BVBA/SPRL company logo - Safety Data Sheet supplier organization

3M Belgium BVBA/SPRL

manufacturer

Hermeslaan 7, B1831 Diegem

BE

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

+ 32 (0)2 722 54 23

BE

Emergency Contact

+ 32 (0)2 722 5111

BE

buiten de kantooruren

Belgisch Antigifcentrum

+ 32 (0)70 245 245

BE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Hexamethyleendisiloxaan
EC: 203-492-7
107-46-0 65-90% Hazardous
Acrylaat terpolymeer N/A 3-12% Non-hazardous
2,2,4-Trimethylpentaan
EC: 208-759-1
540-84-1 8-12% Hazardous
Silsesquioxanen, Ph 73559-47-4 0.1-5% Non-hazardous

Composition Notes

Gelieve rubriek 16 te raadplegen voor de volledige tekst van de H-zinnen die in deze rubriek genoemd worden Gelieve rubrieken 8 en 12 van dit VIB te consulteren voor informatie betreffende blootstellingswaarden, PBT of zPzBbeoordeling.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Breng de persoon in frisse lucht. Bij onwel voelen een arts raadplegen

Skin Contact

Eerste hulp wordt niet nodig geacht.

Eye Contact

Spoelen met grote hoeveelheden water. Contactlenzen verwijderen, indien mogelijk. Blijven spoelen. Zoek medische hulp als tekens/symptomen ontwikkelen.

Ingestion/Swallowing

NIET het BRAKEN opwekken. Onmiddellijk een arts raadplegen.

Immediate Medical Attention Required

Niet beschikbaar

Medical Treatment

Niet beschikbaar

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Partition Coefficient
Niet van toepassing
Odor Threshold
Geen gegevens beschikbaar
Solubility
Not available
Bulk Density
Not available
Explosive Limits
Not available
Density
0,78 g/ml
Critical Property
Dynamic Viscosity
5 mPa-s
Melting Point
Niet van toepassing
Critical Property
Colour Intensity
Heldere
Upper Explosive Limit
18,3 %
Flash Point
-10 graden C
Critical Property
Relative Density
0,78
State Under Standard Conditions
Not available
Molecular Weight
Not available
Physical State
Vloeistof
Critical Property
Solubility In Fat
Not available
Odor
lichte of geen geur
Vapor Density
Niet van toepassing
Lower Explosive Limit
0,7 %
Physical State Data
liquid
Solidification Point
Not available
Vapor Pressure
< 186.158,4 Pa [@ 55 graden C ]
Solubility In Water
<=0,1 %
Appearance
Heldere kleurloze vloeistof
Properties Status
Not available
Flammability
Niet van toepassing
Voc Content
Geen gegevens beschikbaar
Kinematic Viscosity
Not available
Ph
Niet van toepassing
Cloud Point
Not available
Evaporation Rate
<=1 [ _Testmethode:_ Getest volgens ASTM-protocol] [ _Ref Std:_ ETHER=1]
Form
vloeistof
Colour
kleurloze
Metal Corrosion
Not available
Relative Evaporation Rate
<=1
Decomposition Temperature
Geen gegevens beschikbaar
Boiling Point
100 graden C
Critical Property
Freezing Point
Not available
Crystallisation Point
Not available
Auto Ignition Temperature
351,7 graden C
Softening Point
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Gebruik een algemene verdunningsventilatie en / of plaatselijke afzuiging om de luchtconcentratie onder de relevante blootstellingslimieten te houden en/of de controle te bewaren over stof / rook / gas / nevel / damp of spuitnevel. Indien ventilatie onvoldoende is, gebruik ademhalingsbescherming.

Hand Protection

Beschermende handschoenen zijn niet vereist. Het dragen van handschoenen als bescherming tegen chemicaliën is niet vereist.

Eye Protection

Oogbescherming wordt niet nodig geacht.

Respiratory Protection

Niet van toepassing. Een blootstellinganalyse kan nodig zijn om te beslissen of een gasmasker nodig is. Als een gasmasker nodig is, gebruik deze dan als onderdeel van een volledige ademhalingbeschermingsprogramma. Selecteer, op basis van de resultaten van de blootstellingsanalyse, een van de volgende gasmaskertypen om blootstelling door inhalatie te verminderen: Halfgelaatsstuk of volgelaatsstuk luchtzuiveringsrespirator geschikt voor kwikdamp en -deeltjes. Voor vragen omtrent de geschiktheid voor een specifiek gebruik, raadpleeg uw leverancier van het masker. Normen/Standaarden van Toepassing: Gebruik een ademhalingsbeschermingsmasker dat voldoet aan EN 140 of EN 136: filter types Hg & P

Environmental Exposure Controls

Raadpleeg de Annex voor bijkomende informatie.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1866

Proper Shipping Name

RESIN SOLUTION

Transport Hazard Class

3

Packing Group

II

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for 3M™ Cavilon™ No Sting Barrier Film Spray (IO) Cat. # 3346, 3346E, 3346P?

The signal word for this substance is "no signal word".

What is the physical form of 3M™ Cavilon™ No Sting Barrier Film Spray (IO) Cat. # 3346, 3346E, 3346P?

3M™ Cavilon™ No Sting Barrier Film Spray (IO) Cat. # 3346, 3346E, 3346P is a vloeistof appearing as heldere kleurloze vloeistof with kleurloze color. It has lichte of geen geur odor.

What is 3M™ Cavilon™ No Sting Barrier Film Spray (IO) Cat. # 3346, 3346E, 3346P used for?

Huidbeschermende Barrièrefilm.

What is the melting point of 3M™ Cavilon™ No Sting Barrier Film Spray (IO) Cat. # 3346, 3346E, 3346P?

The melting point is Niet van toepassing and the boiling point is 100 graden C.