NextSDS Logo
GR

GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR

DANGER Vloeibaar SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Kleefstof

Overview

GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR commonly used kleefstof.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

danger (Gevaar)

Hazard Classifications

Flam. Liq. Category 2 H225
Eye Irrit. Category 2 H319
STOT SE Category 3 H336

GHS Hazard Pictograms & Safety Symbols

GHS02 GHS Hazard Pictogram: Flammable hazard - Fire risk materials including gases, liquids, and solids

GHS02

GHS07 GHS Hazard Pictogram: Health hazard warning - Materials harmful to health including irritants and sensitizers

GHS07

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

  • H225: Licht ontvlambare vloeistof en damp.
  • H319: Veroorzaakt ernstige oogirritatie.
  • H336: Kan slaperigheid of duizeligheid veroorzaken.

Precautionary Statements

  • P101: Bij het inwinnen van medisch advies, de verpakking of het etiket ter beschikking houden.
  • P102: Buiten het bereik van kinderen houden.
  • P210: Verwijderd houden van warmte, hete oppervlakken, vonken, open vuur en andere ontstekingsbronnen. Niet roken.
  • P261: Inademing van damp vermijden.
  • P370+P378: In geval van brand: Blussen met: waternevel, alcoholbestendig schuim, bluspoeder, kooldioxide.
  • P403+P233: Op een goed geventileerde plaats bewaren. In goed gesloten verpakking bewaren.
  • P501: De inhoud/verpakking afvoeren overeenkomstig de nationale voorschriften.
Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Bison International

manufacturer

Dr.A.F.Philipsstraat 9 NL-4462 EW Goes PO Box 160 NL-4460 AD Goes

NL

+31 88 3235700

+31 88 3235800

Bison International

undefined

Excelsiorlaan 27, B 3 B-1930 Zaventem

BE

+32 3 710 92 92

+32 3 710 92 90

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Antigifcentrum

075 245245

BE

Emergency Contact

8002 - 5500

LU

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Kleefstof

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
Ethylacetate
EC: 205-500-4
141-78-6 25-50% Hazardous
ethylmethylketon / butanone
EC: 201-159-0
78-93-3 25-50% Hazardous
aceton;propaan-2-on;propanon
EC: 200-662-2
67-64-1 10-25% Hazardous

Additional Information

De woordelijke inhoud van de opgegeven aanwijzingen inzake de mogelijke gevaren is te vinden in hoofdstuk 16.

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

Frisse lucht toedienen; bij klachten arts ontbieden.

Eye Contact

De ogen gedurende verscheidene minuten onder stromend water afspoelen terwijl de oogspleet geopend blijft. Bij aanhoudende klachten een dokter raadplegen.

Ingestion/Swallowing

Geen braken opwekken en onmiddellijk medische hulp inroepen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Solidification Point
Not available
Odor
Esterachtig
Density
0,912 g/cm
Critical Property
Vapor Pressure
233 hPa
Bulk Density
Not available
Dynamic Viscosity
600 mPas
Melting Point
Niet bepaald.
Critical Property
Properties Status
Not available
Solubility In Water
Niet resp. gering mengbaar.
Metal Corrosion
Not available
Flash Point
-19 C
Critical Property
Lower Explosive Limit
1,8 Vol %
Vapor Density
Niet bepaald.
Form
Vloeibaar
Colour
Kleurloos
Kinematic Viscosity
Niet bepaald.
Explosive Limits
Not available
Appearance
Not available
State Under Standard Conditions
Not available
Voc Content
Not available
Softening Point
Not available
Colour Intensity
Not available
Evaporation Rate
Niet bepaald.
Decomposition Temperature
Niet bepaald.
Solubility In Fat
Not available
Boiling Point
76 C
Critical Property
Molecular Weight
Not available
Relative Density
Niet bepaald.
Freezing Point
Niet bepaald.
Flammability
Niet bruikbaar.
Upper Explosive Limit
13 Vol %
Solubility
Not available
Cloud Point
Not available
Physical State
Vloeibaar
Critical Property
Crystallisation Point
Not available
Auto Ignition Temperature
460 C
Physical State Data
liquid
Partition Coefficient
Niet bepaald.
Ph
Niet bepaald.
Odor Threshold
Niet bepaald.
Relative Evaporation Rate
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Hand Protection

Handschoenen / bestand tegen oplosmiddelen. Het handschoenmateriaal moet ondoorlatend en bestand zijn tegen het product / de stof / de bereiding. Kies handschoenmateriaal rekening houdend met de penetratietijden, de permeatiegraden en de degradatie. Handschoenmateriaal: Butylrubber. Aanbevolen materiaaldikte: > 0.7 mm. De keuze van een geschikte handschoen is niet alleen afhankelijk van het materiaal, maar ook van andere kwaliteitskenmerken en verschilt van fabrikant tot fabrikant. Aangezien het product uit meerdere stoffen is samengesteld, is de duurzaamheid van de handschoenmaterialen niet vooraf berekenbaar en moet derhalve vr het gebruik worden getest. De precieze penetratietijd kunt u te weten komen bij de handschoenfabrikant; houd er rekening mee. Voor het mengsel van de hieronder vermelde chemicalin moet de penetratietijd minstens 120 minuten bedragen (permeatie volgens EN 374 Deel 3: Level 4).

Eye Protection

Nauw aansluitende veiligheidsbril

Respiratory Protection

Bij onvoldoende ventilatie ademhalingsbescherming. Aanbevolen filter voor kortstondig gebruik: Filter AX, Filter A

Skin/Body Protection

Tegen oplosmiddelen bestande beschermingskleding

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

UN Number

UN1133

Proper Shipping Name

ADHESIVES

Transport Hazard Class

3 Brandbare vloeistoffen

Packing Group

II

IMDG Maritime Transport Precautions

Waarschuwing: Brandbare vloeistoffen

IATA Air Transport Precautions

Waarschuwing: Brandbare vloeistoffen

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR?

The signal word for this substance is "danger".

What is the physical form of GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR?

GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR is a vloeibaar with kleurloos color. It has esterachtig odor.

What is GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR used for?

Kleefstof

What are the hazard statements for GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR?

This substance has 3 hazard statements: H225: Licht ontvlambare vloeistof en damp. H319: Veroorzaakt ernstige oogirritatie. H336: Kan slaperigheid of duizeligheid veroorzaken.

What is the melting point of GR 95 DYKA HARD PVC LIJM BOT 250ML*12 NLFR?

The melting point is Niet bepaald. and the boiling point is 76 C.