NextSDS Logo
SU

SUPERCUT Aerosol

NO SIGNAL WORD Vloeistof onder druk SDS/MSDS

Chemical Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
SUPERCUT Aerosol

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Smeermiddelen Hoogwaardige snijolie

Overview

SUPERCUT Aerosol is a vloeistof onder druk substance commonly used smeermiddelen hoogwaardige snijolie.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Chemical Manufacturers & Supply Chain

Authorized suppliers, manufacturers, and distribution network information

CRC Industries Europe bvba

global supplier

๐Ÿ“

Touwslagerstraat 1 9240 ZELE Belgium

๐ŸŒ

BE

๐Ÿ“ 

(+32)(0)52/450034

CRC Industries Finland

national supplier

๐Ÿ“

Asemanrinne 13, 08500 Lohja AS

๐ŸŒ

FI

๐Ÿ“ž

(+358)(0)19/32921

๐Ÿ“ 

(+358)(0)19/383676

CRC Industries France

national supplier

๐Ÿ“

12, Bld des Martyrs de Chateaubriant F-95102 Argenteuil Cdex

๐ŸŒ

FR

๐Ÿ“ž

(+33)(0)1/34112000

๐Ÿ“ 

(+33)(0)1/34110996

CRC Industries Deutschland

national supplier

๐Ÿ“

Sdring 9, 76473 Iffezheim

๐ŸŒ

DE

๐Ÿ“ž

(+49)(0)7229/3030

๐Ÿ“ 

(+49)(0)7229/303266

CRC Industries Iberia

national supplier

๐Ÿ“

Gremio del cuero S/N, 40195 Segovia

๐ŸŒ

ES

๐Ÿ“ž

(+34)921/427546

๐Ÿ“ 

(+34)921/436270

CRC Industries Sweden

national supplier

๐Ÿ“

Kryptongatan 14, 43153 Mlndal

๐ŸŒ

SE

๐Ÿ“ž

(+46)(0)31/7068480

๐Ÿ“ 

(+46)(0)31/273991

24/7 Emergency Response & Poison Control

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Emergency Contact

๐Ÿ“ž

(+32) (0)52/45 60 11

๐ŸŒ

BE

Antigifcentrum/Centre Antipoisons

๐Ÿ“ž

070 - 245 245

๐ŸŒ

BE

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

mixture

General Composition

Contains 60-100% mineral oil.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
koolstofdioxide
EC: 204-696-9
124-38-9 1% โš ๏ธ Hazardous
Benzenepropanoic acid, 4-hydroxy-
EC: 207-931-3
501-97-3 0.25% โš ๏ธ Hazardous
polysulfides, di-tert-dodecyl
EC: 270-335-7
68425-15-0 2.5% โš ๏ธ Hazardous
zinkalkyldithiofosfaat
EC: 272-028-3
68649-42-3 0.5% โš ๏ธ Hazardous
tetrafluoroethane
EC: 212-377-0
811-97-2 5-10% โš ๏ธ Hazardous
minerale olie (IP 346 DMSO extract < 3%)
EC: 265-098-1
niet gekend 60-100% โš ๏ธ Hazardous
2-ethylhexylzincdithiophosphate N0137 1.5% โš ๏ธ Hazardous

Composition Notes

Nota H en L van Annex 1 (67/548/EEG) zijn van toepassing voor bepaalde complexe aardoliederivaten in dit product.

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

๐Ÿซ Inhalation Exposure

Frisse lucht, warm en rustig houden.

๐Ÿ–๏ธ Skin Contact

Wassen met water en zeep.

๐Ÿ‘๏ธ Eye Contact

Als de stof in de ogen komt, onmiddellijk met veel water uitspoelen

๐Ÿฝ๏ธ Ingestion/Swallowing

Inslikken is onwaarschijnlijk Na inslikken niet laten braken Een arts raadplegen

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

๐Ÿงช Physical State
Vloeistof onder druk
Critical Property
๐Ÿ“Š Physical State Data
aerosol
๐Ÿ“Š State Under Standard Conditions
Not available
๐Ÿ‘๏ธ Appearance
Vloeistof onder druk
๐ŸŽจ Colour
amberkleur
๐Ÿ“Š Colour Intensity
Not available
๐Ÿ“Š Form
Not available
๐Ÿ‘ƒ Odor
olie
๐Ÿ“Š Odor Threshold
Not available
๐Ÿงช Ph
niet van toepassing
๐ŸงŠ Melting Point
niet gekend
Critical Property
๐Ÿ’จ Boiling Point
niet gekend
Critical Property
๐Ÿ”ฅ Flash Point
195 C (Open Cup)
Critical Property
๐Ÿ“Š Freezing Point
Not available
๐Ÿ“Š Softening Point
Not available
๐Ÿ“Š Solidification Point
Not available
๐Ÿ“Š Cloud Point
Not available
๐Ÿ“Š Crystallisation Point
Not available
๐Ÿ“Š Relative Evaporation Rate
Not available
๐Ÿ’จ Evaporation Rate
niet van toepassing
๐Ÿ’จ Vapor Pressure
niet gekend
๐Ÿ“Š Vapor Density
niet gekend
๐Ÿ“Š Relative Density
0.88 g/cm3 (@ 20C)
๐Ÿ“Š Bulk Density
Not available
โš–๏ธ Density
Not available
๐Ÿ”ฅ Flammability
Not available
๐Ÿ“Š Upper Explosive Limit
Not available
๐Ÿ“Š Lower Explosive Limit
Not available
๐Ÿ“Š Explosive Limits
Not available
๐Ÿ“Š Auto Ignition Temperature
- 200 C
๐Ÿ“Š Decomposition Temperature
Not available
๐Ÿ’ง Solubility
Not available
๐Ÿ“Š Partition Coefficient
niet gekend
๐Ÿ“Š Solubility In Water
Niet oplosbaar in water
๐Ÿ“Š Solubility In Fat
Not available
๐Ÿ“Š Molecular Weight
Not available
๐Ÿ“Š Voc Content
Not available
๐Ÿ“Š Metal Corrosion
Not available
๐Ÿ“Š Dynamic Viscosity
Not available
๐Ÿ“Š Kinematic Viscosity
Not available
๐Ÿ“Š Properties Status
Not available

Exposure Controls & Personal Protective Equipment (PPE)

Occupational exposure limits, engineering controls, and required safety equipment

๐Ÿญ Engineering Controls

Voor voldoende ventilatie zorgen

๐Ÿ˜ท Respiratory Protection

Uitsluitend op goed geventileerde plaatsen gebruiken Als blootstelling hoger is dan MEL/OES, moet een erkend ademhalingsapparaat gebruikt worden

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

๐Ÿท๏ธ UN Number

1950

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for SUPERCUT Aerosol?

The signal word for this substance is "no signal word".

What is the physical form of SUPERCUT Aerosol?

SUPERCUT Aerosol is a vloeistof onder druk appearing as vloeistof onder druk with amberkleur color. It has olie odor.

What is SUPERCUT Aerosol used for?

Smeermiddelen Hoogwaardige snijolie

What is the melting point of SUPERCUT Aerosol?

The melting point is niet gekend and the boiling point is niet gekend.