NextSDS Logo
Re

Reag. Ph Eur

NO SIGNAL WORD vast SDS/MSDS
Chemical Identity

Product Identification & Regulatory Data

Official chemical identifiers, CAS numbers, and regulatory compliance information

Basic Product Information

Product Name
Reag. Ph Eur
Product Code
105043

Regulatory Identifiers

CAS Number
N/A

Chemical Abstracts Service registry number - unique identifier for chemical substances

Uses Information

Identified Uses
Reagens voor analyse

Overview

Reag. Ph Eur commonly used reagens voor analyse.

Manage Your Safety Data Sheets

Organize and access your chemical safety data with ease.

Safety Classification

GHS Hazard Classification & Safety Warnings

Globally Harmonized System (GHS) hazard pictograms, signal words, and safety classifications

Classification Status

Classified

Signal Word

no signal word

GHS Hazard Pictograms & Safety Symbols

GHS (Globally Harmonized System) pictograms indicate specific chemical hazard categories and safety precautions

Hazard Statements

Precautionary Statements

Supply Chain

Manufacturers & Suppliers

Authorized suppliers, manufacturers, and distribution network information

Merck KGaA company logo - Safety Data Sheet supplier organization

Merck KGaA

manufacturer

64271 Darmstadt * Duitsland

DE

+49 6151 727780

Emergency

24/7 Emergency Response

Critical emergency contact numbers for chemical spills, exposure incidents, and medical emergencies

Merck KGaA

+49 6151 722440

DE

Composition

Chemical Composition & Hazardous Ingredients

Detailed component analysis, concentration ranges, and hazardous substance identification

Product Type

substance

General Composition

Geen bestanddelen die verplicht openbaar moeten worden gemaakt volgens v erordening (EG) nr. 1907/2006.

Chemical Components & Hazardous Substances

Chemical Name CAS Number Concentration Hazardous
N/A N/A Not specified Non-hazardous

Additional Information

Voor de volledige text van H-zinnen zoals vermeld in deze rubriek, zie rubriek 16. De veiligheidsinformatiebladen van de catalogusartikelen staan ter beschikking op www.merck-chemicals.com

First Aid

Emergency First Aid Measures

Critical first aid procedures for chemical exposure incidents and medical emergencies

Inhalation Exposure

frisse lucht.

Skin Contact

met ruim voldoende water afspoelen. Verontreinigde kleding verwijderen.

Eye Contact

ooglid wijd open houden en uitspoelen met veel water. Indien nodig oogarts raadplegen.

Ingestion/Swallowing

slachtoffer water laten drinken (niet meer dan twee glazen). Indien onwel: arts raadplegen.

Alternatives

Related Chemical Substances & Alternative Products

Similar chemicals with comparable safety profiles and industrial applications

Section 9

Technical Specifications & Material Properties

Physical state, chemical properties, melting point, boiling point, and material characteristics

Voc Content
Not available
Dynamic Viscosity
Geen gegevens beschikbaar.
Odor
reukloos
Relative Evaporation Rate
Not available
Properties Status
Not available
Melting Point
723 C
Critical Property
Evaporation Rate
Geen gegevens beschikbaar.
Colour Intensity
Not available
Relative Density
3,13 g/cm bij 20 C
Flammability
Geen gegevens beschikbaar.
Solubility In Water
1.430 g/l bij 20 C
Cloud Point
Not available
Bulk Density
ca.1.500 kg/m
Ph
ca. 6,9 bij 50 g/l 20 C
Decomposition Temperature
Geen gegevens beschikbaar.
Kinematic Viscosity
Not available
Colour
gebroken wit
State Under Standard Conditions
Not available
Density
Not available
Vapor Density
Not available
Boiling Point
1.325 C bij 1.013 hPa
Critical Property
Auto Ignition Temperature
Geen gegevens beschikbaar.
Partition Coefficient
Geen gegevens beschikbaar.
Odor Threshold
Geen gegevens beschikbaar.
Molecular Weight
Not available
Solubility In Fat
Not available
Freezing Point
Not available
Metal Corrosion
Not available
Vapor Pressure
Geen gegevens beschikbaar.
Upper Explosive Limit
Geen gegevens beschikbaar.
Explosive Limits
Not available
Lower Explosive Limit
Geen gegevens beschikbaar.
Physical State
vast
Critical Property
Crystallisation Point
Not available
Physical State Data
solid
Form
vast
Flash Point
ontvlamt niet
Critical Property
Softening Point
Not available
Solubility
Not available
Appearance
Not available
Solidification Point
Not available
Section 8

Exposure Controls & Personal Protective Equipment

Occupational exposure limits, engineering controls, and required safety equipment

Engineering Controls

Technische maatregelen en geschikte werkprocedures zouden prioriteit moe ten hebben boven het gebruik van persoonlijke beschermingsmiddelen. Zie paragraaf 7.1.

Hand Protection

volledig contact: Handschoenenmateriaal: Nitrilrubber, Handschoendikte: 0,11 mm, Penetratietijd: - 480 min. spat contact: Handschoenenmateriaal: Nitrilrubber, Handschoendikte: 0,11 mm, Penetratietijd: - 480 min. De te gebruiken beschermende handschoenen, moeten voldoen aan de specificaties van EG regeling 89/686/EEG en de daaruit voortkomende norm EN374, bij voorbeeld KCL 741 Dermatril L (volledig contact), KCL 741 Dermatril L (spat contact). De bovengenoemde doorbraak tijden, werden met materiaalproeven van de aanbevolen handschoenen door KCL in laboratoriummetingen vlgs. EN374 onderzocht. Deze aanbeveling heeft alleen betrekking op het in het veilgheidsinformatieblad genoemde product, voor de door ons aangegeven toepassingen. Wanneer het middel wordt opgelost in, of vermengd met andere substanties, onder andere condities dan vermeld in EN374 neemt u dan svp contact op met de leverancier van de CE-goedgekeurde handschoenen (b.v. KCL GmbH, D-36124 Eichenzell, Internet: www.kcl.de).

Eye Protection

Veiligheidsbril

Respiratory Protection

nodig indien stofvorming plaatsvindt. Aanbevolen filtertype: Filter P 2 (volgens DIN 3181) voor vaste en vloeibare deeltjes van schadelijke stoffen. De ondernemer moet er voor zorgen dat onderhoud, reiniging en beproeving van adembeschermingstoestellen worden uitgevoerd volgens de voorschriften van de leverancier. Deze maatregelen moeten uitvoerig zijn gedocumenterd.

Skin/Body Protection

Het soort lichaamsbescherming moet al naargelang van de concentratie en de hoeveelheid gevaarlijke stoffen op de werkplek gekozen worden. De chemische weerstand van de bescherming moet met de leverancier geregeld worden.

Environmental Exposure Controls

Afval niet in de gootsteen werpen.

Section 14

Transportation & Shipping Information

UN numbers, shipping names, transport classes, and regulatory transport requirements

FAQ

Chemical Safety FAQ & Common Questions

Most frequently asked questions about safety, handling, storage, and regulatory compliance

What is the hazard signal word for Reag. Ph Eur?

The signal word for this substance is "no signal word".

What is the physical form of Reag. Ph Eur?

Reag. Ph Eur is a vast with gebroken wit color. It has reukloos odor.

What is Reag. Ph Eur used for?

Reagens voor analyse

What is the melting point of Reag. Ph Eur?

The melting point is 723 C and the boiling point is 1.325 C bij 1.013 hPa.